Nortel Networks NORSTAR P0886634 user manual

User manual for the device Nortel Networks NORSTAR P0886634

Device: Nortel Networks NORSTAR P0886634
Category: Answering Machine
Manufacturer: Nortel Networks
Size: 0.57 MB
Added : 9/13/2013
Number of pages: 37
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Nortel Networks NORSTAR P0886634. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Nortel Networks NORSTAR P0886634.

For your convenience

If looking through the Nortel Networks NORSTAR P0886634 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Nortel Networks NORSTAR P0886634 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Nortel Networks NORSTAR P0886634 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Nortel Networks NORSTAR P0886634 User manual - Online PDF
Advertisement
« Page 1 of 37 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Nortel Networks NORSTAR P0886634 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Nortel Networks NORSTAR P0886634. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


••••••••••••••••••••••••••••••••••••••••••••
Norstar Voice Mail 4.0 FAX
Installation Guide
•••••••••••••••••••••••••

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Contents Regulatory information iii Repair facilities iv Chapter 1 Introduction to Norstar Voice Mail FAX 1 FAX overview 1 DFC overview 3 Specifications 3 Special tools 3 Precautions 4 Enabling the FAX software 4 Chapter 2 Installing the DFC on systems equipped with DVCs 5 Installation overview 6 Shutting down the Norstar Voice Mail system 6 Opening the NAM 7 Installing the DFC in the NAM 8 Installing the PEB Cable 11 Enabling the FAX software 13 Adding

Summary of the content on the page No. 4

ii FAX Installation Guide P0886634 Issue 1.0

Summary of the content on the page No. 5

Regulatory information iii Regulatory information FCC Regulations This equipment complies with Part 68 Rules and Regulations of the FCC Regulations for direct connection to the public switched telephone network. DOC Regulations This equipment complies with CS-03 Rules and Regulations of the Canadian DOC Regulations for direct connection to the public switched telephone network. Radio frequency interference Warning: This equipment generates, uses, and can radiate radio frequency

Summary of the content on the page No. 6

iv Repair facilities Repair facilities In the event of equipment malfunction, all repairs must be performed by Northern Telecom or by one of its authorized dealers. In the USA: In Canada: Northern Telecom Inc. Northern Telecom Canada Ltd. Nashville Repair and Distribution Center 30 Norelco Drive 640 Massman Drive Weston, ON Nashville, TN 37210 M9L 2X6 Attn: RA# Tel: (416) 744-5201 Tel: (615) 883-9220 Fax: (416) 744-5227 Note: You receive an RA# when you call the repair center in Nas

Summary of the content on the page No. 7

Introduction to Norstar Voice Mail FAX 1 Norstar Voice Mail FAX provides Norstar Voice Mail with fax functionality. This installation guide is intended for the installer of Norstar Voice Mail FAX and describes how the FAX option should be installed and prepared for operation. Norstar Voice Mail FAX can be installed on systems equipped with either a Media Services Base Interface Card (BIC) or Digital Voice Cards (DVC)s. The procedures for installing the Digital Fax Card (DFC) differs b

Summary of the content on the page No. 8

2 Introduction to Norstar Voice Mail FAX Figure 1 FAX overview External fax machine External caller receives a fax from Fax-on-Demand Mailbox. OR Fax sent to office fax machine behind Norstar or to a Personal Mailbox. Personal Mailbox Other office receives a fax as part of a message. Norstar office Mailboxes are accessed and fax programming is done from here. Fax Overflow Mailbox stores faxes if office fax machine is busy and prints them later. DVC or BIC Norstar Telephone DFC Nor

Summary of the content on the page No. 9

Introduction to Norstar Voice Mail FAX 3 DFC overview The Digital Fax Card (DFC) is installed in an expansion bus slot on the Norstar Application Module (NAM) and supports four Fax Channels. There are no Time Compression Multiplexing (TCM) connections to the DFC. The DFC uses the Voice Channels on the Digital Voice Cards (DVCs) or BIC to connect the Fax Channels to fax machines or a call. Note: When Norstar Voice Mail FAX is using a Voice Channel to connect to the fax

Summary of the content on the page No. 10

4 Introduction to Norstar Voice Mail FAX Precautions Before installing or upgrading a DFC, you must take the following precautions: • Shut down the Norstar Voice Mail system—A shutdown procedure allows Norstar Voice Mail to perform all necessary shutdown activities before power is removed. For more information, refer to "Shutting down the Norstar Voice Mail system" on page 6. • Unplug the NAM power cord—The NAM power supply contains high voltage. If you do not unplug the

Summary of the content on the page No. 11

Installing the DFC on systems equipped with 2 DVCs Only one DFC can be installed in the Norstar Applications Module (NAM). The DFC connects to the DVCs through the PCM Expansion Bus (PEB) cable. This cable must be connected from the DFC to each DVC. The PEB cable connects the DFC to the DVC to share the ports connected to Norstar. The following section provides step-by-step instructions for the installation of the FAX software, a DFC and the PEB cable in a Norstar Voice Mail system equ

Summary of the content on the page No. 12

6 Installing the DFC on systems equipped with DVCs Installation overview To add Norstar Voice Mail FAX to a system equipped with DVCs you must: • Set the DFC jumpers • Install the DFC • Connect the DFC to the DVCs with the PEB cable • Enable the FAX software Shutting down the Norstar Voice Mail system Before you remove the power from Norstar Voice Mail, you must shutdown the Norstar Voice Mail system. Performing a shutdown allows Norstar Voice Mail to perfor

Summary of the content on the page No. 13

Installing the DFC on systems equipped with DVCs 7 Opening the NAM 1. Warn customers that Norstar Voice Mail will be out of service while you are installing the FAX option. 2. Shutdown the Norstar Voice Mail system. Note: For information about performing a shutdown, refer to "Shutting down the Norstar Voice Mail system" on page 6. 3. Unplug the NAM power cord from the AC outlet. 4. Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grou

Summary of the content on the page No. 14

8 Installing the DFC on systems equipped with DVCs Figure 4 Removing the front cover Installing the DFC in the NAM 1. Make sure you are wearing your antistatic grounding strap. Ground yourself by attaching one end of the grounding strap to your wrist and the other end to a grounded metal surface. 2. If you are installing FAX on an earlier NAM, locate slot 7 on the expansion bus. Remove the slot cover screw and the metal slot cover from the slot. Refer to Figure 5 on page 9. If you ar

Summary of the content on the page No. 15

Installing the DFC on systems equipped with DVCs 9 Figure 5 Locating the expansion bus slots on a NAM DFC - Slot 7 Figure 6 Locating the expansion bus slots on a NAM II DFC - Slot 8 P0886634 Issue 1.0 FAX Installation Guide

Summary of the content on the page No. 16

10 Installing the DFC on systems equipped with DVCs 3. Switch SW1 should be set according to the following table: Position87654321 State off on off off on on on on 4. Switch SW2 should be set according to the following table: Position 2 1 State on on 5. Ensure there is a jumper on position 10 of the INTERRUPT. Note: The settings in these table are the default values and should be set properly when the board is received. Refer to Figure 2 on page 5 for the location of the switch SW1, SW2 a

Summary of the content on the page No. 17

Installing the DFC on systems equipped with DVCs 11 Installing the PEB Cable Figure 7 shows an example of how the PEB cable is installed on an earlier NAM. In this example, the Norstar Voice Mail module is equipped with four DVCs. The DFC is at the right end of the PEB “chain” in slot 7 and the leftmost DVC, DVC 1, is at the other end of the chain in slot 3. Figure 7 NAM PEB Cable installation example DFC DVC4 DVC2 Slot 7 DVC3 Slot 6 DVC1 Slot 5 Slot 4 Slot 3 Figure 8 shows an example of how

Summary of the content on the page No. 18

12 Installing the DFC on systems equipped with DVCs 1. Remove all DVCs from the NAM. 2. Remove the PEB terminator XRN2 from DVC 1. Refer to Figure 9 for the location of the PEB terminators. Figure 9 Digital Voice Card PEB connector PEB terminator XRN1 PEB terminator XRN2 To remove a PEB terminator, place a flat-head screwdriver between the terminator and its socket and gently pry the terminator loose. Figure 10 Removing a PEB terminator 3. Remove both PEB terminators, XRN1 and XRN2, from any

Summary of the content on the page No. 19

Installing the DFC on systems equipped with DVCs 13 Figure 11 Installing the PEB Cable PEB Connector DFC Interrupt SW2 SW1 PEB Terminator 5. Insert the DVCs and connect the PEB cable to each card. Note: To ease installation, start with the DVC that is closest to the DFC and finish with the DVC farthest away. Also make sure you connect the PEB cable before you insert the next DVC. 6. Fold the PEB cable so it lies flat against the card edges. 7. Proceed to step 1 of Enabling the FAX software. E

Summary of the content on the page No. 20

14 Installing the DFC on systems equipped with DVCs 6. Close the module door. Note: To lock the door, turn the lock 90° clockwise until the screwdriver slot is horizontal. 7. Plug the power cord into the AC outlet. Adding a Digital Voice Card after FAX is installed After you have installed the FAX option on the NAM, the installation of another DVC requires a few extra steps. These extra steps are required to remove PEB terminators and install the PEB cable. To install a DVC: 1. Warn customer


Alternative user manuals
# User manual Category Download
1 Nortel Networks Central Answering Position User manual Answering Machine 8
2 Nortel Networks Meridian Mail User manual Answering Machine 5
3 Nortel Networks Norstar Voice Mail 4.0 User manual Answering Machine 1
4 Nortel Networks 2050 User manual Answering Machine 1
5 Nortel Networks 150 User manual Answering Machine 1
6 Nortel Networks Enterprise Edge Voice Messaging User manual Answering Machine 1
7 Nortel Networks CalPilot 4.0 User manual Answering Machine 2
8 Nortel Networks P0908524 User manual Answering Machine 1
9 Nortel Networks P0857846 User manual Answering Machine 2
10 Nortel Networks Voice Mail User manual Answering Machine 1
11 Nortel Networks P0911621 User manual Answering Machine 1
12 Nortel Networks P0911632 User manual Answering Machine 1
13 Nortel Networks P0911951 User manual Answering Machine 1
14 Nortel Networks CallPilot P091943002 User manual Answering Machine 2
15 Sony 6 User manual Answering Machine 0
16 Sony TAM-100 User manual Answering Machine 138
17 Philips CD455 User manual Answering Machine 69
18 Philips DECT5251S User manual Answering Machine 4
19 Philips Elegance 55 User manual Answering Machine 87