Summary of the content on the page No. 1
Installation Manual
®
ENFORCER
E-941SA-1200
E-941SA-600
E-941SA-300
Electromagnetic Locks
Also available:
E-941SA-1K2PD E-941DA-1K2P
Status LED
1200 lb. maglock Double-Door
Status LED
with status LED 1200 lb. maglock
status sensor & with status LEDs &
delay timer status sensors
HOW THEY WORK
When power is applied to the magnetic lock, it turns on the unit's powerful built-
in electromagnet. This electromagnet is attracted to the steel armature plate
which is mounted on a door, holding the door
Summary of the content on the page No. 2
ELECTROMAGNETIC LOCK Installation Manual MOUNTING THE E-941SA-300, E-941SA-600 & E-941SA-1200 A. Drill holes for the mounting plate and 4. Make sure the anti-spin guides are armature plate (see fig. 1 and 2) by in the two guidepin holes. doing the following: C. Screw the mounting plate to the door 1. Fold the mounting template along frame or optional bracket: the dotted line. 1. Screw the two short self-tapping 2. Close the door. Find a mounting screws in the slotted holes of the location on the
Summary of the content on the page No. 3
ELECTROMAGNETIC LOCK Installation Manual FIG. For Inswing Doors 1 Filler Plate* Standard * Note: may require more "L" Bracket "Z" Mounting than one filler plate. Bracket (Z/L brackets are not available for E-941SA-300.) Steel and Steel and Steel and FIG. Rubber washers Rubber Rubber washers Sexnut tube (as needed) washers (as needed) 2 (as Armature needed) 12345 12345678 Sexnut 12345 Armature 12345678 12345 Sexnut bolt Screw 12345 bolt Armature Screw Armature Screw Drill a 8mm Armature This sid
Summary of the content on the page No. 4
ELECTROMAGNETIC LOCK Installation Manual TROUBLESHOOTING Problem: Possible cause: Solutions: Door does not lock No power Check to make sure the wires are securely tightened to the terminal block Check that the power supply is connected and operating Make sure the lock switch is wired correctly Door locks, but can be Poor contact between Make sure the electromagnet and easily forced open electromagnet and armature plate are properly aligned armature plate Make sure the contact surfaces
Summary of the content on the page No. 5
ELECTROMAGNETIC LOCK Installation Manual Page 5