Napco Security Technologies GEM-K2AS user manual

User manual for the device Napco Security Technologies GEM-K2AS

Device: Napco Security Technologies GEM-K2AS
Category: Door
Manufacturer: Napco Security Technologies
Size: 0.45 MB
Added : 8/15/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Napco Security Technologies GEM-K2AS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Napco Security Technologies GEM-K2AS.

For your convenience

If looking through the Napco Security Technologies GEM-K2AS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Napco Security Technologies GEM-K2AS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Napco Security Technologies GEM-K2AS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Napco Security Technologies GEM-K2AS User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Napco Security Technologies GEM-K2AS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Napco Security Technologies GEM-K2AS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATING GUIDE for your

GEM-K2AS KEYPAD
GEMINI
AC ON READY

NEXT / YES
R 1 2 3 P

U

PRIOR / NO
B 4 5 6
Q

AREA
C 7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
© NAPCO 2003 OI280A 4/03
1
STATUS
ARMED

Summary of the content on the page No. 2

INTRODUCTION The GEM-K2AS is a “smart” user- an explanation of terms that may be been configured, rest assured that it has friendly, interactive menu-driven keypad unfamiliar to you. been carefully designed and engineered designed for your Napco control panel. to the highest industry standards. To You'll probably find subjects Its alphanumeric screen will not only assure optimum safety and security, mentioned in this booklet that do not display the status of your system, but will fami

Summary of the content on the page No. 3

TABLE OF CONTENTS TO SILENCE AN ALARM, ENTER YOUR TABLE OF CONTENTS CODE, AND PRESS U. Section Page FOR SERVICE, CALL: _____________________ KEYPAD CONTROLS & INDICATORS ............................................4 CENTRAL STATION: _____________________ ARMING AWAY: SETTING THE ALARM WHEN LEAVING ............6 EXIT DELAY: ___________________________ ARMING STAY: PROTECTING YOURSELF AT H

Summary of the content on the page No. 4

KEYPAD CONTROLS & INDICATORS 1 GEMINI 2 AC ON READY 3 7 NEXT / YES 8 R P 1 2 3 4 U PRIOR / NO 9 B 4 5 6 Q 5 AREA 10 C 7 8 9 0 G 6 11 COMPUTERIZED SECURITY SYSTEM 12 4 ARMED STATUS

Summary of the content on the page No. 5

KEYPAD CONTROLS & INDICATORS Window. Displays system status (2) Unbypasses a bypassed zone the window display. 1 messages, zone descriptions, etc. (GEM-P9600/3200 panels only). AWAY Button. (1) Arms all zones 10 STATUS Light. Lights (green) to 6 RESET Button. (1) Resets in the system, with display 2 indicate that the system is ready various system troubles, displays, indicating the exit time remaining. for arming. If a zone is not etc. (See text.) (2) Resets (2) Scrolls window display

Summary of the content on the page No. 6

ARMING AWAY: SETTING THE ALARM WHEN LEAVING Arming the System READY AC ON Note: The keypad will autoscroll messages that are longer than one line. 1 Check the keypad. The green STATUS light must be on in order to arm. If the green light is off, “FAULT” will display in the window followed by the number of FAULT/ each faulted zone. Note each problem zone and secure it by closing a window, AC ON ZONE 02 door, etc. When all zones are secure, the green STATUS light will turn on

Summary of the content on the page No. 7

ARMING AWAY: SETTING THE ALARM WHEN LEAVING Priority Arming. If you attempt to arm with a faulted Priority Zone, a 3-second tone CAN'T/ will sound at the keypad, and "CAN'T ARM" will display in the window, indicating that the AC ON trouble(s) must be corrected before the panel can be armed. A zone selected as Priority ARM Zone with Bypass (check your Alarm Plan) may be bypassed if in trouble. If the problem cannot be corrected immediately, press C, then arm the panel. A 3 second

Summary of the content on the page No. 8

ARMING AWAY: SETTING THE ALARM WHEN LEAVING If you attempt to arm with a “TROUBLE” display (alternating with a system trouble error code), a 3- TROUBLE SYSTBL/ second tone will sound at the keypad. (See SYSTEM TROUBLE ERROR CODES for descriptions of AC ON codes). The window will display “CAN'T ARM”. If you cannot correct the problem immediately, EXX-XX pressing C will enable you to arm in this condition. Be sure to call for service as soon as possible. TROUBLE CAN'T/ Area Armin

Summary of the content on the page No. 9

ARMING STAY: PROTECTING YOURSELF AT HOME Arming in STAY Mode BYPASSED INTERIOR READY Interior Zones, when bypassed, allow free movement within the premises while the protection of AC ON armed perimeter zones is maintained. Enter your code, then press P. The red ARMED light will turn on and the green STATUS light will blink, indicating zones bypassed. After the exit time has elapsed, the window will display "ARMED". Easy Exit (Optional - Easy Exit programmed? !YES !NO)

Summary of the content on the page No. 10

ARMING STAY: PROTECTING YOURSELF AT HOME Instant Protection INSTANT ON ARMED When retiring for the evening, after all family members are home, you can cancel the entry AC ON delay on the Entry Zone(s). Then, when armed, opening the entry door will cause an immediate alarm. (When arming, exit delay will remain in effect). 1. To cancel the entry delay while on the premises, press and hold down P for 2 seconds after arming. 2. When armed, the window will display “SYSTEM ARMED” a

Summary of the content on the page No. 11

TURNING OFF THE ALARM (DISARMING) WHEN RETURNING Disarming the System DISARM/ 1 Upon entry, the keypad sounder will turn on as a reminder to disarm the panel. The AC ON XXXSEC red ARMED light will be on and the window will alternately display "DISARM" and "XXXSEC", where "XXX" represents the entry time remaining in 10-second steps. During the final 10 seconds, the sounder will pulse a warning signal. Wrong/ AC ON Code 2 Enter your User Code and press U. The sounder will

Summary of the content on the page No. 12

TURNING OFF THE ALARM (DISARMING) WHEN RETURNING Ambush (Optional) Your Ambush Code Type is: !TYPE 1 (Prefix) !TYPE 2 (Unique) My Ambush Code is ___________________ If an intruder forces you to disarm your system, enter your Ambush Code and press U. There are two types of Ambush Codes: (1) A 2-digit code (prefix) entered just prior to your normal User Code and (2) A separate and unique User Code. Example Type 1 (Prefix): If your User Code is 1234 and your Ambush Code is 99, press

Summary of the content on the page No. 13

FIRE PROTECTION (Applicable only where local ordinance permits use of this alarm control panel for fire protection.) Fire-Zone Alarm reset FIRE ALARM FIRE/ If a fire is detected, “reset FIRE ALARM” will be displayed and the keypad sounder will AC ON ZONEXX pulse. 1. If a fire is in progress, evacuate the premises immediately! If necessary, call the Fire Department from an outside phone. 2. Press the C button to silence the keypad sounder. 3. If there is no evidence of a fire, enter

Summary of the content on the page No. 14

FIRE PROTECTION 2. One person sounds the alarm. alternate route through the window. If Preparing a Fire Escape Plan the door is cool, brace your shoulder 3. Each person tests his door. Even with the most advanced fire alarm against it and open it cautiously. Be system, adequate protection requires an 4. Pretend the door is hot and use the ready to slam the door if smoke or heat escape plan. alternate escape exit. rushes in. Crawl through smoke, 5. Everyone meets outdoors at

Summary of the content on the page No. 15

FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below. Floorplan 15

Summary of the content on the page No. 16

FIRE PROTECTION LIMITATIONS OF FIRE ALARM WARNING SYSTEM in reducing fire deaths, may not activate or alert those on a different level. Even those Although a fire alarm system may be of a provide early-enough warning for a variety of who are awake may not hear the warning if reliable and state-of- the-art design, neither it reasons: (a) they may not sense fires that the alarm is obscured by noise from a stereo, nor its peripheral detection devices can offer start where smoke cannot reach

Summary of the content on the page No. 17

FUNCTION MENU The keypad can provide access to a wide assortment of utility functions. The functions are displayed in a prompting “YES/NO” format. While the messages are shown here in their entirety, actual displays will scroll automatically in two screens. Wait for the entire message to display. To recall an alternate screen, hold down the blue Button. To G skip a function, answer NO (press Q); to select and execute a function, answer YES (press P) or U. The com- plete function list i

Summary of the content on the page No. 18

FUNCTION MENU Display Telephone List? (For GEM-P9600/3200 panels only) (OPTIONAL--Phone Numbers Pro- DspTel/List/ grammed? !YES !NO) The panel can dial any of four programmed telephone numbers. Yes/No AC ON Select Telephone #1-4 using the NEXT and PRIOR buttons. Press U, then pick up the phone to automatically dial the displayed number. Displays a 2-digit error code Display System Troubles? (For GEM-P9600/3200 panels only) DspSys/Trbl/ (EXX-NN) represent

Summary of the content on the page No. 19

FUNCTION MENU Activate Chime? "MONITOR ON" will be displayed and the Chime Mode will sound a tone at TurnOn/Chime the keypad when the programmed zone is opened while disarmed. To deactivate the Chime Yes/No AC ON Mode, execute the "TurnOff Chime" function. Note: The Chime Mode is disabled while armed. Activate Watch Mode? (Watch Mode programmed? !YES !NO). This optional feature si- TurnOn/Watch multaneously turns on all zones designated as Day Z

Summary of the content on the page No. 20

FUNCTION MENU Delay Arming 1-4 hours. (Not for UL-listed systems). Your system may be set to Delay/Arm 1-4/ /No arm automatically after a delay period of 1 to 4 hours, 15 minutes, as follows: AC ON For a 1-hour, 15-minute delay, press 1, then U. For a 2-hour, 15-minute delay, press 2, then U. For a 3-hour, 15-minute delay, press 3, then U. For a 4-hour, 15-minute delay, press 4, then U. Fifteen minutes prior to arming, the siren will sound a 2 second warning and the key- pad will


Alternative user manuals
# User manual Category Download
1 Napco Security Technologies GEM-DXRP3 User manual Door 0
2 Napco Security Technologies GEM-DXK3 User manual Door 0
3 Napco Security Technologies GEM-P816 User manual Door 88
4 Napco Security Technologies GEM-RP3DGTL User manual Door 67
5 Napco Security Technologies GEM-P9600 User manual Door 39
6 Napco Security Technologies GEM-P1632 User manual Door 164
7 Sony SCHLAGE LINK BE369 User manual Door 6
8 3Com TECHD-0000000050 User manual Door 1
9 Ace Hardware User manual Door 1
10 American Standard 6034.STE2 User manual Door 0
11 American Standard 6000.STE1 User manual Door 1
12 American Standard 4834.STE1 User manual Door 0
13 American Standard Acrylux 3600Y1.STE5 User manual Door 0
14 American Standard Acrylux 3200Y1.STE5 User manual Door 0
15 American Standard 4242.STE5 User manual Door 0