Guardian Technologies ACT1000 user manual

User manual for the device Guardian Technologies ACT1000

Device: Guardian Technologies ACT1000
Category: Door
Manufacturer: Guardian Technologies
Size: 0.92 MB
Added : 8/11/2014
Number of pages: 35
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Guardian Technologies ACT1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Guardian Technologies ACT1000.

For your convenience

If looking through the Guardian Technologies ACT1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Guardian Technologies ACT1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Guardian Technologies ACT1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Guardian Technologies ACT1000 User manual - Online PDF
Advertisement
« Page 1 of 35 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Guardian Technologies ACT1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Guardian Technologies ACT1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Instrucciones de funcionamiento e instalación de las unidades de control del acceso ACT
Instrucciones de funcionamiento e instalación de las unidades de control del acceso ACT
Operating & Installation Instructions for
ACT1000/2000 Access Control Units

Downloaded from: http://www.guardianalarms.net

Summary of the content on the page No. 2

Contents Default Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Menu Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Text Entry Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ……………. 1 Operator Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ……….. 2 User Set-up . . . . . . .

Summary of the content on the page No. 3

Contents Door Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. ..16 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 16 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... 16 Timers . . . . . …. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Timed Actions . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

ACT1000/2000 Operating Instructions Software Version 3.23-00 Operating Instructions for ACT1000/2000 Access Control Units Software Version: 3.23-00 All user functions are accessed via two six-digit codes. The first code is for the Operator who is responsible for the day-to-day administration of the system, adding and deleting users, setting names and assigning time-zones etc. The second code is for the Installer who performs the in

Summary of the content on the page No. 5

ACT1000/2000 Operating Instructions Software Version 3.23-00 Operator Menu Allow a user or range of users to open the door User Setup Enable Prevent a user or range of users from opening the door Disable Enter a name for each user Assign Names Assign users to groups Assign Groups Specify options for each user Assign Options Set the individual PIN for each user Assign PINs Learn randomly coded cards (e.g. Bank Cards) L

Summary of the content on the page No. 6

ACT1000/2000 Operating Instructions Software Version 3.23-00 User Setup The User Setup menu allows the operator to enable and disable individual users, and to change the configuration information for each user. In each of the user setup functions, the user is selected by either using the 0 key to advance to the required user, or alternatively by using the numeric keys 1-9 to directly enter the number of the desired user. The top line

Summary of the content on the page No. 7

ACT1000/2000 Operating Instructions Software Version 3.23-00 Assign PINs The Assign PINs function allows a different PIN to be assigned to each of the first 1000/2000 users. Initially, the PIN will be unset. Pressing the ✔✔ key will prompt for the PIN ✔✔ for the displayed user to be entered (it will not be displayed). The PIN must then be re- entered for verification. The PIN will be accepted as long as it does not conflict with any ex

Summary of the content on the page No. 8

ACT1000/2000 Operating Instructions Software Version 3.23-00 One-To-One In One-To-One Mode, any known card may be assigned to any of the first 1000/2000 users. If the site code and card number are known then they may be entered in from the keypad or the card may also be presented to a reader (similar to Learn Mode). Card Validity (ACT 2000 Only) The Card Validity menu allows any of the first 2000 users to be assigned a validity perio

Summary of the content on the page No. 9

ACT1000/2000 Operating Instructions Software Version 3.23-00 3) Changing timezone Timezone 0 for next timezone At all times ✔✔✔✔ to select 4) Changing door combination Door 7 0 for next door ✔✔ to select/deselect [23---7—AB] ✔✔ ✘✘✘✘ when done In addition, Full Access or No Access may quickly be set for the group by highlighting and selecting the + or – symbols respectively: 5) Setting Full Access ✔✔ to set full access A B

Summary of the content on the page No. 10

ACT1000/2000 Operating Instructions Software Version 3.23-00 Display Log The Display Log function allows the operator to view events in the historical log directly on the LCD display. When this option is selected, the latest event in the log is displayed with the time and date on the top line of the display, and the event details being scrolled across the bottom line. Each log event will be displayed in turn (stepping backwards in time

Summary of the content on the page No. 11

ACT1000/2000 Operating Instructions Software Version 3.23-00 Control Door The Control Door menu allows the operator to control the door or externally connected equipment such as lighting or heating. Lock Door The Lock Door function causes the door relay to be de-energized. The bottom line of the display will show “Door Locked” and the red LED on the reader will flash. All subsequent cards will be rejected until the door is unlo

Summary of the content on the page No. 12

ACT1000/2000 Operating Instructions Software Version 3.23-00 Clear All (ACT2000 Only) This function manually removes all users from the area. An event is logged for tracking. This is typically used at the end of a day or week to remove any users from the system who have neglected to use their cards when exiting. Set Date/Time The Set Date/Time function allows the operator to adjust the date and time on the controller’s real-time cl

Summary of the content on the page No. 13

ACT1000/2000 Operating Instructions Software Version 3.23-00 1) Select Timezone Timezone 3 0 for next timezone Inactive ✔✔✔✔ to edit timezone 2) Select period A B C D E + - 0 for next period Week Days ✔✔✔✔ to edit period 08:30 -> 17:00 3) Changing days/holidays Wednesday 0 for next day/holiday [TWTF--1—4] ✔✔✔✔ to select/deselect ✘✘✘✘ when done 4) Changing time period Period 0-9 to set time ✔✔ for next minute/hour

Summary of the content on the page No. 14

ACT1000/2000 Operating Instructions Software Version 3.23-00 Issue Number This option allows the user to set the current system issue level to a number between zero (default) and 255. Only cards that have an issue number greater than or equal to the system issue level will be granted access. A card without an issue number encoded (Proximity, Wiegand, etc.) has an effective issue level of zero. Issue numbering is intended for use in

Summary of the content on the page No. 15

ACT1000/2000 Operating Instructions Software Version 3.23-00 Installer Menu PIN’s alone are used to gain access System Settings Operation PIN Only Users 1-1/2000 may use random coded cards Learn 1 Use external ACT20 keypad Ext. Keypad 1 ✔✔ Key is exit button. ✔✔ KPD Release Exit PIN’s may be used in PIN only mode Exit PIN’s 1 Second (Auxiliary) door enabled on ACT1000 Second Door Prevent access if the user limit is

Summary of the content on the page No. 16

ACT1000/2000 Operating Instructions Software Version 3.23-00 Time for which relay is active Door Settings* Timers Relay Time Time for which OP2 is active (contd.) OP2 Time Time for which OP3 is active OP3 Time Max time which door can be open Ajar Time Time for which AUX output is active AUX Time Buzzer o/p active if door left ajar Reporting Door Ajar Door Forced events report in log Door Forced Door Open event

Summary of the content on the page No. 17

ACT1000/2000 Operating Instructions Software Version 3.23-00 System Settings The System Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the setup of the controller. Pressing the ✔✔✔✔ key toggles the setting of a displayed option. Operation This menu allows the installer to select or de-select a number of options relating to the default operation of the contr

Summary of the content on the page No. 18

ACT1000/2000 Operating Instructions Software Version 3.23-00 Fire Doors This function allows a group of doors (or all doors) to be configured for fire override. A 0Volt signal from a fire alarm (or other) system is applied to the AUX input on door 1. This maintains normal operation. When the 0Volt signal is removed, the selected doors are held open until the 0Volt signal is re-applied. Typically, a normally-closed relay on the fire panel

Summary of the content on the page No. 19

ACT1000/2000 Operating Instructions Software Version 3.23-00 Door Settings The Door Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the selected door. The door for which the settings are to be changed is first selected using the 0 key, then the ✔✔✔✔ key is pressed to enter the menu. The 0 key is used to select the required option or setting which is changed usi

Summary of the content on the page No. 20

ACT1000/2000 Operating Instructions Software Version 3.23-00 Timers The door timers menu allows the installer to program the time delays for the relay, AUX output, open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer may be programmed with a duration from 1 to 999 seconds. The relay time may be programmed to 0 seconds, which will operate the relay for a quarter of a second approximately. This can be used for turns


Alternative user manuals
# User manual Category Download
1 Guardian Technologies ACT2000 User manual Door 3
2 Sony SCHLAGE LINK BE369 User manual Door 6
3 3Com TECHD-0000000050 User manual Door 1
4 Ace Hardware User manual Door 1
5 American Standard 6034.STE2 User manual Door 0
6 American Standard 6000.STE1 User manual Door 1
7 American Standard 4834.STE1 User manual Door 0
8 American Standard Acrylux 3600Y1.STE5 User manual Door 0
9 American Standard Acrylux 3200Y1.STE5 User manual Door 0
10 American Standard 4242.STE5 User manual Door 0
11 American Standard 4834.STE5 User manual Door 0
12 American Standard Acrylux Framed By-Pass Shower User manual Door 0
13 American Standard 6034.STE1 User manual Door 0
14 American Standard Pivot 3232.STE2 User manual Door 0
15 American Standard Pivot 3232.STE5 User manual Door 0