Lifebreath 200ERV user manual

User manual for the device Lifebreath 200ERV

Device: Lifebreath 200ERV
Category: Air Cleaner
Manufacturer: Lifebreath
Size: 1.13 MB
Added : 7/17/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lifebreath 200ERV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lifebreath 200ERV.

For your convenience

If looking through the Lifebreath 200ERV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lifebreath 200ERV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lifebreath 200ERV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lifebreath 200ERV User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lifebreath 200ERV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lifebreath 200ERV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
CLEAN • FRESH • AIR
OPERATION AND
INSTALLATION MANUAL
Contains
ControlAir 15
IMPORTANT - PLEASE READ THIS
For Models:
MANUAL BEFORE INSTALLING UNIT
95MAX
155MAX
CAUTION
Before installation, careful consideration must be given to
200MAX
how this system will operate if connected to any other piece
of mechanical equipment, i.e. a forced air furnace or air
handler, operating at a higher static. After installation, the
MAXTOP
compatibility of the two pieces of equipment must be
confirmed by measu

Summary of the content on the page No. 2

INTRODUCTION Table of Contents HRV - Aluminum Core Introduction................................................................... 2 A Heat Recovery Ventilator (HRV) is designed to Warranty ....................................................................... 2 provide fresh air into a building while exhausting an ERV Questions & Answers .......................................... 3 equal amount of stale air. During the winter months, the incoming cold fresh air is warmed by Climate Map .....

Summary of the content on the page No. 3

ERV Questions & Answers What is the difference between an HRV and damp situation. In fact, about 2/3 of the energy and an ERV? used by the air conditioner system is to remove The core in an HRV (Heat Recovery Ventilator) moisture. Therefore, when ventilating in the summer, transfers heat from one air stream to the other. This is less moisture brought into the home means less work called sensible heat. The term ERV (Energy Recovery for the air conditioner, and energy savings for you. Ventilator)

Summary of the content on the page No. 4

4

Summary of the content on the page No. 5

Model 95MAX PERFORMANCE HVI CERTIFIED ENGINEERING DATA Net supply airflow in cfm (L/s) against external static pressure THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE E.S.P cfm L/s The cross-flow heat recovery core transfers heat between the two @ 0.1” (25 Pa) 89 (42) airstreams. It is easily removed for cleaning or service. @ 0.2” (50 Pa) 78 (37) MOTORS AND BLOWERS - Each air stream has one centrifugal @ 0.3” (75 Pa) 64 (30) blower driven by a common PSC motor. 5 speed fan operation. 120 VAC, .8

Summary of the content on the page No. 6

Model 155MAX PERFORMANCE ENGINEERING DATA HVI CERTIFIED Net supply airflow in cfm (L/s) against external static pressure THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE E.S.P cfm L/s The cross-flow heat recovery core transfers heat between the two @ 0.1” (25 Pa) 169 (80) airstreams. It is easily removed for cleaning or service. @ 0.2” (50 Pa) 161 (76) MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. @ 0.3” (75 Pa) 150 (71) 120 VA

Summary of the content on the page No. 7

Model 200MAX ENGINEERING DATA PERFORMANCE HVI CERTIFIED THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Net supply airflow in cfm (L/s) against external static pressure The cross-flow heat recovery core transfers heat between the two E.S.P cfm L/s airstreams. It is easily removed for cleaning or service. @ 0.1” (25 Pa) 232 (109) MOTORS AND BLOWERS - Each air stream has one centrifugal @ 0.2” (50 Pa) 223 (105) blower driven by a common PSC motor. 5 speed fan operation. @ 0.3” (75 Pa) 215 (102) 120

Summary of the content on the page No. 8

Model MAXTOP ENGINEERING DATA PERFORMANCE HVI CERTIFIED THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Net supply airflow in cfm (L/s) against external static pressure E.S.P cfm L/s The cross-flow heat recovery core transfers heat between the two @ 0.1” (25 Pa) 196 (93) airstreams. It is easily removed for cleaning or service. @ 0.2” (50 Pa) 188 (89) MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. @ 0.3” (75 Pa) 178 (84) 120 V

Summary of the content on the page No. 9

Model 195DCS ENGINEERING DATA PERFORMANCE HVI CERTIFIED THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Net supply airflow in cfm (L/s) against external static pressure The cross-flow heat recovery core transfers heat between the two E.S.P cfm L/s airstreams. The two cores are arranged for highly efficient counter @ 0.1” (25 Pa) 203 (96) current airflow. @ 0.2” (50 Pa) 191 (90) MOTORS AND BLOWERS - Each air stream has one centrifugal @ 0.3” (75 Pa) 182 (86) blower driven by a common PSC motor. 5

Summary of the content on the page No. 10

Model 300DCS ENGINEERING DATA PERFORMANCE THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE HVI CERTIFIED The cross-flow heat recovery core transfers heat between the two Net supply airflow in cfm (L/s) against external static pressure E.S.P cfm L/s airstreams The two cores are arranged for highly efficient counter @ 0.1” (25 Pa) 265 (125) current airflow. @ 0.2” (50 Pa) 260 (123) MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation.

Summary of the content on the page No. 11

® Model 200ERV CLEAN • FRESH • AIR PERFORMANCE ENGINEERING DATA Net supply airflow in cfm (L/s) against external static pressure LATENT RECOVERY/MOISTURE TRANSFER CORE E.S.P cfm L/s The cross-flow energy recovery core transfers heat and water @ 0.1” (25 Pa) 214 (101) vapour between the two airstreams. It is easily removed for cleaning or service. @ 0.2” (50 Pa) 206 (97) MOTORS AND BLOWERS - Each air stream has one centrifugal @ 0.3” (75 Pa) 193 (91) blower driven by a common PSC motor. 5 speed

Summary of the content on the page No. 12

® Model 200ERVD CLEAN • FRESH • AIR ENGINEERING DATA PERFORMANCE LATENT RECOVERY/MOISTURE TRANSFER CORE Net supply airflow in cfm (L/s) against external static pressure The cross-flow energy recovery core transfers heat and water vapour E.S.P cfm L/s between the two airstreams. It is easily removed for cleaning or service. @ 0.1” (25 Pa) 214 (101) MOTORS AND BLOWERS - Each air stream has one centrifugal @ 0.2” (50 Pa) 206 (97) blower driven by a common PSC motor. 5 speed fan operation. High s

Summary of the content on the page No. 13

FUNCTION & CONTROL Operating the ControlAir 15 Self Test Plugging in the HRV/ERV energizes the unit. A self test Each time the HRV/ERV is powered/energized the self test function will automatically initiate. During the self function will be performed every time the HRV/ERV is energized (refer to “Self Test” for more details). After test the HRV/ERV will cycle through all the speeds available (1-5), test the damper motor operation and will the self test has completed successfully the HRV/ERV

Summary of the content on the page No. 14

To select mode of operation for ControlAir 15 Press and hold the fan selection button on the Control Pad. After 5 seconds the control will begin to cycle each mode holding each for 2 seconds. Release the button when the desired mode of operation is reached. Modes of Operation LED Indication OFF No LED’s illuminated HRV/ERV is off, no controls will initiate operation. Standby / On Steady Green LED and Yellow LED to indicate speed HRV/ERV will run at speed selected in ventilation mode. Standby

Summary of the content on the page No. 15

ControlAir 15 OPTIONAL REMOTE CONTROLS PROGRAMMABLE VENTILATION CONTROLLER (PVC) NEW! AIR SENTRY™ AIR QUALITY SENSOR LOCATION: Hallway, kitchen, office LOCATION: Kitchen, basement, & work place (connect 1/unit only) work place (connect 1/unit only). • Advanced digital remote. • Digital Air Quality Monitor. • Digital dehumidistat. • Status light indicates fan speed. • Full fan speed control. • Increases ventilation to remove • AIR SENTRY™ Air Quality Sensor built-in. odours and contamina

Summary of the content on the page No. 16

USING THE DEHUMIDISTAT Some models have a built-in dehumidistat (an exceeds the set point on the control. Once the optional remote wall mount dehumidistat can be humidity in the house is reduced, the HRV/ERV installed, see Optional Remote Controls), to will revert back to its previous setting.The control harmful, excess humidity during the dehumidistat should be set to off for all seasons heating season. The dehumidistat operates in except the heating season. % of RH (relative humidity) with

Summary of the content on the page No. 17

¤ HEAT RECOVERY VENTILATORS (HRVs) ¤ HEAT RECOVERY VENTILATORS (HRVs) DIMENSIONS 95MAX inches (mm) 18.5" Hanging (470 mm) straps (4) knockout for Threaded side mounting of inserts (4) EXHAUST return port at corners 6" round collar converted to oval 18.5" (470 mm) EXHAUST Stale Air SUPPLY to outside Fresh air 5" round collar Removably from outside Heat Recovery 5" round collar Core EXHAUST Return air from building SUPPLY Fresh air minimum Choice of port location to building 18 inches (459 mm

Summary of the content on the page No. 18

INSTALLATION Location The HRV/ERV must be located in a heated space where it will Connecting Appliances to the HRV/ERV be possible to conveniently service the unit. Typically the It is not recommended that any of the following appliances be HRV/ERV would be located in the mechanical room or an connected to the HRV/ERV: area close to the outside wall where the weatherhoods will be • clothes dryer mounted. If a basement area is not convenient or does not • range top exist, a utility or laundry roo

Summary of the content on the page No. 19

INSTALLING AIR DUCTS A well designed and installed ducting system will allow the To minimize air flow restriction, the flexible insulated duct that connects the two outside weatherhoods to the HRV/ERV HRV/ERV to operate at its maximum efficiency. should be stretched tightly and be as short as possible. Always try to keep duct runs as short and straight as possible. See Installation Diagrams for various installation options. Twisting or folding the duct will severely restrict air flow. See below

Summary of the content on the page No. 20

SUPPLY AIR DUCTING Dampers and Grilles In homes without a forced air furnace, fresh air should be The use of balancing dampers and/or adjustable grilles to supplied to all bedrooms and living areas, excluding balance the flow rates into various rooms is recommended. bathrooms, kitchen and utility areas. It should be supplied We suggest TECHGRILLE™ air diffusers. from high wall or ceiling locations. Grilles that diffuse the air comfortably such as the Techgrille™ are recommended. • The TECHGRIL


Alternative user manuals
# User manual Category Download
1 Lifebreath 1000RHCAC User manual Air Cleaner 2
2 Lifebreath 1200FD/DD User manual Air Cleaner 0
3 Lifebreath 155MAX RX User manual Air Cleaner 5
4 Lifebreath 155ECM User manual Air Cleaner 2
5 Lifebreath 195ECM User manual Air Cleaner 0
6 Lifebreath 1200ERV User manual Air Cleaner 0
7 Lifebreath 500DCS User manual Air Cleaner 0
8 Lifebreath 195DCS User manual Air Cleaner 3
9 Lifebreath 1200DDPOOL User manual Air Cleaner 0
10 Lifebreath 500ERV User manual Air Cleaner 1
11 Lifebreath 200MAX RX User manual Air Cleaner 1
12 Lifebreath 300DCS User manual Air Cleaner 0
13 Lifebreath 200ERVD User manual Air Cleaner 0
14 Lifebreath CONTROLAIR 15 95MAX User manual Air Cleaner 3
15 Lifebreath Console User manual Air Cleaner 0
16 Sony PK-HS1FL User manual Air Cleaner 1920
17 Sony PK-R1FL User manual Air Cleaner 11
18 Philips AC4053 User manual Air Cleaner 30
19 Philips AC4002/00 User manual Air Cleaner 13
20 Philips AC4055 User manual Air Cleaner 9