Summary of the content on the page No. 1
FreeFlow Accxes
Customer Release Notes
Version 13.0 b 141
(for 6279 only)
Contents
2 Introduction
2 Feature Keys
3 Release Deliverables
4 Recommended Configurations
5 Release Installation
6 New Features
7 Release Notes
15 Customer Issues Resolved
December, 2008
Summary of the content on the page No. 2
FreeFlow Accxes Customer Release Notes Version 13.0 b 141 Introduction The FreeFlow® Accxes® Controller Firmware Release 13.0 b 141 provides multinational software for the Xerox 6279 and for the Xerox Wide Format Scan System. The languages supported are English, Deutsch, Espanol, Francais, Italiano, Portugues, and Russian. This document presents the following information about the FreeFlow® Accxes® Controller Release 13.0 build 141. The document applies to FRX, and LVX controllers and
Summary of the content on the page No. 3
Release Deliverables Xerox 6279 Wide Format Solution The following executable is provided for the Xerox 6279 Wide Format Solution and supports the Xerox Wide Format Scan System and GFI finisher. FRX & LVX Controller: FRX_LVX_6279_13_0b141.disk.bin (file size = 54,615,971 bytes) 3
Summary of the content on the page No. 4
Recommended Configurations The following table specifies the RAM requirements for the various systems and configurations supported by the FreeFlow Accxes controller. FRX Controller LVX Controller System Min Recommend Min Recommend Any System with the following 2GB 2GB 2GB 2GB feature keys: • AutoCAD • OtherCAD • RASTER 6279 2GB 2GB 2GB 2GB 4
Summary of the content on the page No. 5
Release Installation This version of Accxes (13.0 b 141) requires OS Install CD version 4.1 or higher. BSP Kernel revision 2.6.22.9- 61.fc6 or later is also required. Service is required to upgrade from earlier Accxes® revisions. Regarding scanner firmware revisions: If you are upgrading the firmware of a system containing a Xerox Wide Format Scanner, you must also ensure that the scanner firmware is upgraded, prior to upgrading the controller, to the following version: IMPORTANT NOT
Summary of the content on the page No. 6
New Features in FreeFlow Accxes version 13.0 Support for 6279 Printer and Scanner and User Interface The 6279 includes a new color touch screen user interface. The user interface controls the scanner functionality as well as the printer queue and other print related functions. Scan to Remote Printer (TotalAccxes) The FreeFlow Accxes 13.0 release includes a new feature allowing the user to make a scan in any mode and have the resulting file print on a remote wide format printer.
Summary of the content on the page No. 7
Release Notes The following information supplements the 13.0 customer user guides Total Accxes An issue has been seen with submitting 150 and 200 dpi color and grayscale images to office printers. Submission of 300, 400 and 600 dpi images have been more reliable, though higher resolutions require monger processing times. Sets For 600 DPI engines (6279) the maximum number of ARCH E sized documents that will collate reliably in a set is 150. If the documents will not collate properly
Summary of the content on the page No. 8
Wide Format Scanner Copy Templates lost after reboot The copy and scan templates defined on a Wide Format Scan system will be lost after a power cycle. Clear Last Image When the “Clear Last Image” feature is selected on the Xerox Wide Format Scan System, it may take a few minutes for a Photo or Color mode scanned document to clear out. After scanning a document, this feature is accessed by selecting the “C” key on the scanner. It will bring up the “CLEAR SCANNED IMAGE” screen. Us
Summary of the content on the page No. 9
Manual Feed Manual feed media source will be ignored when used with the Accxes Client Tools’ page composition feature Go to Accxes Client Tools > Job Option tab > Composition tab > Select Overlay Images > Media Source drop down menu. Although “Manual Feed” is listed as a choice of media source for page composition jobs, the print job will be treated as if AUTO media source was selected. If an appropriate roll of media is available, it will be printed on that media; otherwise, the job
Summary of the content on the page No. 10
Web Printer Management Tool (continued) HPGL Page – End of File If the files are streamed via any port on the system, these are treated as a single job and no reset is done between them. However, if one uses the LPD protocol to send the files one at a time, the effect is that the printer is reset after each job. If the “Reinitialize after EOF” is set to be on, the FreeFlow Accxes firmware will reset the printing parameters after each plot file that is received by a serial port or a par
Summary of the content on the page No. 11
Disk Image Overwrite Overview The Disk Image Overwrite feature has two operations: Immediate and On Demand. The immediate operation overwrites image data on the hard drive immediately after it is no longer needed (i.e. When the page has printed). The On Demand operation cleans the entire disk. Both On Demand Image Overwrite and Immediate Image overwrite feature are configured by the system administrator, assuming that the system administrator password is set to a non-zero value.
Summary of the content on the page No. 12
6279 Specific Notes Overview This section is clarification to the existing documentation available for the 6279 system. Timer Reset Button This button will reset the timer value to the previous setting, NOT to the factory default setting. Shared Settings Many of the setting for Scan-to-Mailbox and Scan-to-Network are shared and so many of the settings made on one will stay when selecting the other. Can’t interrupt multi-page/set operations When creating a collated copy set or
Summary of the content on the page No. 13
Windows 2008 security settings and TotalAccxes When using TotalAccxes on Windows 2008 servers, you must make some security setting changes to allow for the configuration of remote destinations. One of the following will work. Enable scripting. a. Go to Tools->Internet Options->Security b. Click on 'Custom level...' for the 'Internet' security zone. c. Scroll down until you reach the category 'Scripting' and set 'Active Scripting' to enabled. Add th
Summary of the content on the page No. 14
Customer Issues Resolved The following issues were resolved in 13.0 build 141 Issue Description Problem Resolution Wide Format Scan System was not Proper operation of the system One can now use the Synergix properly enabled for system use was not attained. scanner on a 6279 with FreeFlow Accxes 13.0 build 141. Could not properly build sets. Could not scan document that exited out the rear of the scanner. Power Cycles of the Wide Format Scan System would cause faults in FreeFlow
Summary of the content on the page No. 15
Page left blank intentionally 15
Summary of the content on the page No. 16
Prepared by: Xerox Corporation 800 Phillips Road Building 139-26A Webster, New York 14580-9791 USA ©XEROX Corporation. 2008. All rights reserved. XEROX®, the sphere of connectivity design, XEROX Wide Format 6279, 6204, 6030, 6050, 6050A, 510, 721, 8825, 8830, 8850, Xerox Wide Format Scan System, FreeFlow® Accxes®, and acronyms, are trademarks of Xerox Corporation in the United States and/or other countri