Summary of the content on the page No. 1
MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS
Operator's Manual
Series
with GA-1211
Series
with GA-1310
Summary of the content on the page No. 2
©2008, 2009 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without prior written permission of TTEC. No patent liability is assumed, however, with respect to the use of the information contained herein.
Summary of the content on the page No. 3
Preface Thank you for purchasing TOSHIBA Multifunctional Digital Color Systems. This manual provides information about system restrictions and the GA-1211/GA-1310 specific functions applied when the GA-1211/GA-1310 controller is connected to the e-STUDIO4520C Series/e-STUDIO6530C Series. Read this manual before using your Multifunctional Digital Color Systems. Keep this manual within easy reach, and use it to configure an environment that makes the best use of the e-STUDIO’s functions. Regar
Summary of the content on the page No. 4
Summary of the content on the page No. 5
CONTENTS Preface....................................................................................................................................... 1 Chapter 1 RESTRICTIONS Operations from the Control Panel......................................................................................... 6 COPY .................................................................................................................................... 6 SCAN .....................................................
Summary of the content on the page No. 6
4 CONTENTS
Summary of the content on the page No. 7
1.RESTRICTIONS This chapter describes system restrictions when the GA-1211 controller is connected to the e-STUDIO4520C series or GA-1310 controller is connected to the e-STUDIO6530C series. Operations from the Control Panel......................................................................................... 6 COPY .....................................................................................................................................................................6 SCAN ......
Summary of the content on the page No. 8
1 RESTRICTIONS Operations from the Control Panel The e-STUDIO4520C series machine with the GA-1211 controller attached or e-STUDIO6530C series machine with the GA-1310 controller attached has several restrictions in the following operations: P.6 “COPY” P.6 “SCAN” P.7 “PRINT” P.7 “FAX” P.8 “USER FUNCTIONS” P.9 “JOB STATUS” Buttons and items enclosed in red lines on the following screenshots in this section disappear or become dim when the controller is connected to the equipment. All th
Summary of the content on the page No. 9
1 RESTRICTIONS 1.RESTRICTIONS PRINT The following related to the [PRINT] button cannot be used when the controller is connected to the equipment: The Private Print function for printing a document from a computer on the network only when a set password is keyed in to the equipment's control panel The Proof Print function for printing only a single copy as a sample and suspending the rest of the job when you print multiple copies from a computer on the network The USB Direct Print function
Summary of the content on the page No. 10
1 RESTRICTIONS USER FUNCTIONS The e-STUDIO4520C series machine with the GA-1211 controller attached or e-STUDIO6530C series machine with the GA-1310 controller attached has several restrictions in the following operation menus: P.8 “USER menu in USER FUNCTIONS” P.8 “ADMIN menu in USER FUNCTIONS” USER menu in USER FUNCTIONS The following related to the USER menu cannot be used when the controller is connected to the equipment: The BLUETOOTH PRINTING setting that allows you to print an image
Summary of the content on the page No. 11
1 RESTRICTIONS 1.RESTRICTIONS NETWORK menu in ADMIN menu The following provided for the NETWORK menu are unavailable. [IPv6] [IPX/SPX] [NETWARE] [SMB] [APPLETALK] [ETHERNET] [IPsec] [NETWORK CHECK] e-STUDIO machine with the controller or e-STUDIO4520C series/e-STUDIO6530C series e-STUDIO4520C Pro series/e-STUDIO6530C Pro series The setting operations for [IPv4] and [HTTP] differ depending on the equipment with or without the controller. For instructions on how to make settings for [IPv
Summary of the content on the page No. 12
1 RESTRICTIONS INTERRUPT The [INTERRUPT] button on the control panel cannot be used while printing is in progress when the controller is connected to the equipment. For details on the [INTERRUPT] button, refer to the Copying Guide. 10 Operations from the Control Panel
Summary of the content on the page No. 13
1 RESTRICTIONS TopAccess USER Mode The e-STUDIO4520C series machine with the GA-1211 controller attached or e-STUDIO6530C series machine with the GA-1310 controller attached has several restrictions in the following TopAccess USER mode operations: P.11 “Launching TopAccess” P.11 “TopAccess top page” P.12 “Registering from TopAccess” Launching TopAccess The following methods for launching TopAccess cannot be used when the controller is connected to the equipment: Launching TopAccess by usin
Summary of the content on the page No. 14
1 RESTRICTIONS e-STUDIO machine with the controller or e-STUDIO4520C Pro series/e-STUDIO6530C Pro series For details on the TopAccess top page, refer to the TopAccess Guide. Registering from TopAccess Registering private templates The following combinations of private template agents cannot be used when the controller is connected to the equipment: The Copy agent cannot be combined with the Save as file agent. e-STUDIO machine with the controller or e-STUDIO4520C series/e-STUDIO6530C series e
Summary of the content on the page No. 15
1 RESTRICTIONS 1.RESTRICTIONS When the controller is connected to the equipment, the GA-1211/GA-1310 specific agents ([SMB/FTP/OTHER] check box) appear in the above page. From this page, you can create the GA-1211/GA-1310 specific private templates. For instructions on how to create them, see the following section: P.35 “Registering or editing GA-1211/GA-1310 specific private templates” Furthermore, the data destination of the Save as file agent is fixed to “Save to USB Media”. e-STUDIO machi
Summary of the content on the page No. 16
1 RESTRICTIONS TopAccess ADMIN Mode The e-STUDIO4520C series machine with the GA-1211 controller attached or e-STUDIO6530C series machine with the GA-1310 controller attached has several restrictions in the following TopAccess ADMIN mode operations: P.14 “Setting up from TopAccess” P.17 “Maintaining from TopAccess” P.17 “Registering from TopAccess” Setting up from TopAccess Setup page The following menus are unavailable when the controller is connected to the equipment: Save as file Prin
Summary of the content on the page No. 17
1 RESTRICTIONS 1.RESTRICTIONS e-STUDIO machine with the controller or e-STUDIO4520C series/e-STUDIO6530C series e-STUDIO4520C Pro series/e-STUDIO6530C Pro series Setting up SNMP Network Service The following provided for the SNMP Network Service are unavailable when the controller is connected to the equipment. Enable SNMP V3 SNMP V3 User Information/ Enable SNMP V3 Trap Number SNMP V3 Trap User Name SNMP V3 Trap Authentication SNMP V3 Trap Privacy Protocol Protocol IPX Trap Address e-ST
Summary of the content on the page No. 18
1 RESTRICTIONS e-STUDIO machine with the controller or e-STUDIO4520C series/e-STUDIO6530C series e-STUDIO4520C Pro series/e-STUDIO6530C Pro series For details on the Network settings screen, refer to the TopAccess Guide. Setting up Print Service settings The following related to Print Service cannot be used when the controller is connected to the equipment: Raw TCP Print LPD Print IPP Print FTP Print NetWare Print e-STUDIO machine with the controller or e-STUDIO4520C series/e-STUDIO6530C s
Summary of the content on the page No. 19
1 RESTRICTIONS 1.RESTRICTIONS Maintaining from TopAccess The following menus are unavailable when the controller is connected to the equipment: Upload Software Remove Software e-STUDIO machine with the controller or e-STUDIO4520C series/e-STUDIO6530C series e-STUDIO4520C Pro series/e-STUDIO6530C Pro series For details on the Maintenance screen, refer to the TopAccess Guide. Registering from TopAccess Registering public templates The restrictions applied for making public templates are the s
Summary of the content on the page No. 20
1 RESTRICTIONS Software Included in the e-STUDIO Client Utilities CD-ROM The e-STUDIO Client Utilities CD-ROM contains the drivers and utilities listed below. However, some of them are unavailable when the controller is connected to the equipment. e-STUDIO machine with e-STUDIO4520C series/ the controller or e-STUDIO6530C series e-STUDIO4520C Pro series/ e-STUDIO6530C Pro series Client software for the print functions PCL 6 printer driver Yes No PS3 printer driver Yes No XPS printer driver Yes