Lennox International Inc. 504 user manual

User manual for the device Lennox International Inc. 504

Device: Lennox International Inc. 504
Category: Air Cleaner
Manufacturer: Lennox International Inc.
Size: 1.31 MB
Added : 7/17/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lennox International Inc. 504. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lennox International Inc. 504.

For your convenience

If looking through the Lennox International Inc. 504 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lennox International Inc. 504 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lennox International Inc. 504 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lennox International Inc. 504 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lennox International Inc. 504 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lennox International Inc. 504. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AIR CLEANERS/
FILTERS
504,887M
HEALTHY CLIMATE®
04/2010
HEPA BYPASS AIR FILTRATION SYSTEM
HOMEOWNERS MANUAL & DEALER INSTALLATION INSTRUCTIONS
FOR HEALTHY CLIMATE® MODELS HEPA-20, HEPA-40, HEPA-60
Rules for Safe Installation and Operation Shipping and Packing List
Package 1 of 1 contains:
READ AND SAVE
1 - HEPA System
THESE INSTRUCTIONS!
1 - Complete Filter Set (Packed inside Unit)
1 - Warranty Certificate
Please read instructions before installing and using the
1 - Installation Instructi

Summary of the content on the page No. 2

Table of Contents Rules for Safe Installation and Operation ................1 Healthy Climate® Dealer Filter Change Instructions .. 7-8 Shipping and Packing List ........................................1 Healthy Climate® Dealer Motor Assembly Introduction ...............................................................2 Replacement Instructions ...........................................8 General Information ..................................................3 Healthy Climate® Dealer Instal

Summary of the content on the page No. 3

General Information Media Filters The HEPA System’s 3 Stage Filtration Process Media filters strain particulates from the air. The filter The 3 stage filtration process is used to create a very media needs to have tiny holes to allow air to pass effective filtration system. Each filter is independent through, but not particulates. Filter types vary for all and can be changed individually. sorts of purposes. The most effective and proven filter • Stage 1: Carbon pre-filter - The inexpe

Summary of the content on the page No. 4

Parts Identification Cabinet Parts HEPA Cartridge Parts Filter Section Access Panel HEPA Filter (STAGE2) Retaining Clips (4) Carbon Pre-Filter Inlet Collar (STAGE 1) HEPA Filter Mesh Cabinet (Protects HEPA Filter) Outlet Collar Inner Charcoal Filter On/Off Switch (STAGE 3) Motor Section Access Panel figure 1. figure 2. Inside Cabinet (Filter Section) Optional Coconut Shell Carbon Canister RECOMMENDED for greater capacity removal of chemicals and odors. Located inside the HEPA Motor/Im

Summary of the content on the page No. 5

Physical Dimensions of Units A Filter Section Access Panel H E C Air Inlet B F Air Outlet D G Motor Section Access Panel MODEL NO. A B C D E HEPA-20 14.1 18 8.0 6.0 1.0 (358) (457) (203) (152) (25) HEPA-40 16.13 28.25 10.0 8.0 1.75 (410) (718) (254) (203) (44) HEPA-60 16.13 28.25 10.0 8.0 1.75 (410) (718) (254) (203) (44-) I A F G H I J HEPA-20 2.0 1.0 9.0 15.25 1.4 (51) (25) (229) (387) (36) HEPA-40 6.5 1.0 11.0 17.875 1.875 (165) (25) (279) (454) (48) HEPA-60 6.5 1.0 11.0 17.875 1.875

Summary of the content on the page No. 6

Operation 1. Make sure that the unit is plugged into a grounded outlet (120 Volt, 60 Hz). 2. For optimum performance, the HEPA system should operate when the indoor air handler/furnace blower is on. An optional air handler/furnace blower interlock kit can be ordered for ‘cycled’ operation. (see Replacement Parts) 3. Turn the unit on by pressing the on/off switch to the ‘1’ position. The switch should light up when the unit is on. 4. To turn the unit off, press the on/off switch to t

Summary of the content on the page No. 7

Healthy Climate® Dealer Filter Change Instructions g. Repeat steps d through f with the other clips, ! WARNING spacing them evenly on the carbon pre-filter to Electrical Shock Hazard. give it even support. Can cause injury or death. 3. Inner Charcoal Filter Replacement Disconnect all electrical power supplies a. Look inside the HEPA cartridge to locate the two before servicing. ends of the inner charcoal filter. b. Pull one end of the old inner charcoal filter in and Do no operate e

Summary of the content on the page No. 8

Healthy Climate® Dealer Filter Change Instructions b. With each HEPA replacement filter, a new ‘o’ ring the base meet the HEPA filter. is provided. The old one is removed by pinching it e. Support the carbon canister with your fingers so it between two fingers and pulling it off the collar on does not slide out when replacing the HEPA the blower deck. cartridge assembly into the unit. c. Discard old ‘o’ ring. d. Place the new ‘o’ ring onto the collar and slide it 6. Installing the

Summary of the content on the page No. 9

Healthy Climate® Dealer Installation Instructions Forced air handler/furnace systems: The HEPA system should be installed as a bypass system, with part of the return ducted into the HEPA system. The filtered air is then rerouted back into the return air, and continues through the system to be heated/cooled. Typical Return to Return Application Typical Return to Return Application For homes with upflow forced air handler/furnace For homes with horizontal forced air handler/furnace systems.(Ai

Summary of the content on the page No. 10

Healthy Climate® Dealer Installation Instructions Forced air handler/furnace system with an HRV/ERV This application provides filtration of all Outdoor Air (OA) that is brought into the home through the HRV/ERV, thus reducing the introduction of dust, pollen and mold from the outdoor air. For systems that have HRV/ERV units installed, we recommend ducting the ‘fresh air’ outlet from the HRV/ERV into the HEPA system. If the HRV/ERV CFM (cubic feet per minute) rating is lower than that of th

Summary of the content on the page No. 11

Healthy Climate® Dealer Installation Instructions Independent Operation: The HEPA systems can be used independently of any other equipment! The inlet and outlet of the filtration system can be ducted into the same room to create a cleaner environment almost anywhere. The inlet or outlet can also be ducted elsewhere. The inlet and outlet should be installed on opposite sides of the room; however, this varies according to your specific needs. Preparation: Example of Single Room Stand Alone

Summary of the content on the page No. 12

Electrical Diagram Figure 17. Replacement Parts Replacement Part HEPA-20 HEPA-40 HEPA-60 Complete Assembly X4912 X4913 X4914 Motor Assembly X2669 X2669 X2671 HEPA Filter Cartridge w/O-Ring 92X17 92X10 92X10 Carbon Pre-Filter X4137 X4138 X4138 Inner Charcoal Filter X2678 92X09 92X09 Carbon Canister 94X98 98X75 98X75 Optional Blower Interlock (24V relay) X2680 X2680 X2680 30 lb. Ultra VOC Canister (Special Order) N/A 95018-15 95018-15 *for optimal VOC & Aldehyde removal Other Recommeded H


Alternative user manuals
# User manual Category Download
1 Lennox International Inc. 887M User manual Air Cleaner 4
2 Lennox International Inc. PureAir Air Purification System User manual Air Cleaner 1
3 Lennox International Inc. Variable Speed Air Handler CBX40UHV User manual Air Cleaner 5
4 Lennox International Inc. PCO-20C User manual Air Cleaner 2
5 Lennox International Inc. S/ FILTERS User manual Air Cleaner 0
6 Lennox International Inc. PCO-12C User manual Air Cleaner 1
7 Sony PK-HS1FL User manual Air Cleaner 1920
8 Sony PK-R1FL User manual Air Cleaner 11
9 Philips AC4053 User manual Air Cleaner 30
10 Philips AC4002/00 User manual Air Cleaner 13
11 Philips AC4055 User manual Air Cleaner 9
12 Philips AC4054 User manual Air Cleaner 13
13 Philips AC4004/00 User manual Air Cleaner 21
14 Philips AC4055/00 User manual Air Cleaner 10
15 Philips AC4062 User manual Air Cleaner 5