If looking through the Thermador user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Thermador on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Thermador to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Thermador User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Thermador but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Thermador . If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
UNIVERSAL COOK’N’VENT
INSTALLATION INSTRUCTIONS
MODELS: UCV30  UCV36  UCV45
Rating: 120 Volt, 60 Hz., 10.0 Amps.
For Integral Blower Installations:
• Requires Integral Blower: Model # VTN600CVA
 Requires Round Duct Size (6" Diam.)
 Requires Dedicated Branch Circuit Power Supply  120 Volt AC
min. 15 Amps., 3 prong receptacle  60 Hz.
 See Steps 3 and 5 for electrical receptacle and duct outlet location
For Remote Blower Installations:
 Requires Remote Blower: Model # VTR1000Q or V

Summary of the content on the page No. 2

TABLE OF CONTENTS Safety Instructions ..............................................................................................................................................pg. 1 Introduction ..........................................................................................................................................................pg. 2 Step 1 Plan the Installation...............................................................................................................

Summary of the content on the page No. 3

Figure 1 Top Cap Filters Snorkel Blower Assembly J-Box Support Leg Wing Nuts INTRODUCTION GENERAL DESCRIPTION ® The complete Universal Cook‘n‘Vent System consists of the ventilator intake and a blower. See Fig. 1. The blower is either an integral (mounted on the vent intake in the cabinet under the cooktop) or a remote (roof or outside wall mounted). When a remote blower is used, a duct transition is mounted on the ventilator intake in place of the integral blower to connect the intake to the d

Summary of the content on the page No. 4

STEP 1 PLAN THE INSTALLATION Carefully follow the planning procedures listed below. See Figure 2. A. Determine whether a remote or integral blower will E. Provide "make-up air" to installation location to be used. Remote blower installation requires 5 improve performance and prevent problems, such as wires plus a ground wire to run from the fireplace chimney downdrafts. ® Cook‘n’Vent to the blower. F. Investigate potential ductwork routes and choose B. Make sure adequate cabinet and counter spa

Summary of the content on the page No. 5

Figure 2  Be certain to avoid interference with gas and electric supply to cooktop.  Shelving and drawer depths are dependent upon cooktop depth and setback. REMOTE REMOTE INTEGRAL w/ CVT314 w/ CVT7 A 10-3/8" 8-1/16" 12" B 11" 11" 10" Page 4

Summary of the content on the page No. 6

FIGURES 3 THROUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING Figure 3 Figure 4 INTEGRAL BLOWER REMOTE BLOWER Remote Blower Duct Attach- ment Box CVT314 VTN600CVA Wall Cap WC8 12" Min. Ground ROOF MOUNT INSTALLATION THROUGH WALL INSTALLATION Figure 5 Figure 6 INTEGRAL BLOWER REMOTE BLOWER Duct Attachment VTN600CVA Remote Blower Box CVT314 10" Collar BLOWER ROTATED 90° FOR SIDE CONNECTION THROUGH WALL INSTALLATION THROUGH WALL DUCT INSTALLATION Page 5

Summary of the content on the page No. 7

Page 6

Summary of the content on the page No. 8

TABLE 2. DUCT WORK INSTALLATION GUIDELINES  Keep duct runs as short and straight as possible.  Use only duct work constructed of materials that are acceptable by the applicable codes. All duct should  Duct fittings (elbows and transitions) reduce air be 26 gauge or heavier to minimize flex due to air flow. flow efficiency.  If the VTR1000Q is used, then a 10" diam. round  Back to back elbows and "S" turns significantly duct to match the inlet ring is required or a transition reduces air

Summary of the content on the page No. 9

CD OD 1/8" BT SB TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Cooktop CWCDOWOD SB BT, Max++ Model No. Cutout Cutout Overall Overall Minimum Backsplash Width Depth Width Depth Set Back Thickness 30” Cooktops: Installed with UCV30 SGS304* 28-15/16 22-1/4 31 23-3/4 1-1/2 3/4 SGSX304* 28-15/16 22-1/4 31 23-3/4 1-1/2 3/4 CET304 28-3/4 22-1/8 31 23-7/8 2-1/2 0 CEP304 28-3/4 22-1/8 31 23-7/8 2-1/2 0 CEM304 28-3/4 22-1/8 31 23-7/8 2-1/2 0 36”Cooktops: Installed with UC

Summary of the content on the page No. 10

CD 1/8" OD BT SB B. INSTALLATION WITH ANOTHER BRAND OF COOKTOP (Figure 8) The installer will need to have the cooktop installation 2. Calculate the cutout depth, CD: instructions available to complete the installation. All Determine the cooktop overhang (CO) cooktop dimensions should be verified through measure- CO = (COD-CCD)/2 (Assumes front and rear ment prior to cutting the countertop: cooktop overhangs are equal) Calculate the cutout CCW = Cooktop Cutout Width depth, (CD): CCD = Cooktop C

Summary of the content on the page No. 11

STEP 3 PREPARE DUCT CUTOUTS IN CABINET A. Refer to Figure 9. Drop a plumb-line from Point "P" C. Temporarily set intake and cooktop in place and at the center of the rear countertop cutout. attach integral blower (or duct transition fitting if a Mark this point on the bottom of the cabinet. Draw remote blower is installed). Refer to steps 6 and 7. Line AA through this point and parallel to the front Verify that the duct cutouts as marked will match of the cabinet. Through the same point draw Lin

Summary of the content on the page No. 12

STEP 4 STEP 6 INSTALL DUCTWORK MOUNT VENT & COOKTOP (REMOTE BLOWER - if used) A. Remove grease filters and any packing materials from inside the intake. A. Install the ductwork and remote blower (if used) in accordance with the ductwork routing plan devel- B. Set the vent intake into rear of countertop opening. oped in Step 1. Carefully lower it into position so that the flanges on the rear sides and edges fully support the unit hanging B. Make sure that the installation complies with all from t

Summary of the content on the page No. 13

Figure 10 STEP 7 MOUNT INTEGRAL BLOWER OR Remote Blower Transition MOUNT INTEGRAL BLOWER OR Remote Blower Transition Integral Blower VTN600CVA Only A. Place blower in front of intake inside of cabinet, take conduit and blower wires and guide them towards the right at the floor of the cabinet. B. On each side of blower housing there is a flanged edge. When placing the housing onto the intake, these flanges need to be positioned in line with intake flanges. C. Place the support bars over the screw

Summary of the content on the page No. 14

STEP 8 Figure 12 VERIFY INSTALLATION, Snorkel Up/ Down button OPERATION & COOKTOP ALIGNMENT Before performing this procedure, verify that all packing materials were removed from inside the Blower Controls lower enclosure front and that the grease filters have been properly installed. Refer to the Care and Use Manual for instructions regarding filter instal- lation. Plug the vent power cord into a proper electrical recep- tacle and ensure that the circuit is energized. E. Raise and lower the ven

Summary of the content on the page No. 15

NOTES

Summary of the content on the page No. 16

5551 McFadden Avenue, Huntington Beach CA, 92649  800-735-4328 BSH Home Appliances Corp.  Litho in U.S.A. 10/02 5060004249 (8209)


Alternative user manuals
# User manual Category Download
1 Thermador User manual Coffeemaker 3
2 Thermador CD456 User manual Cooktop 0
3 Thermador CE304 User manual Cooktop 0
4 Thermador CE456 User manual Cooktop 0
5 Thermador CEM304FS User manual Cooktop 0
6 Thermador CEF User manual Cooktop 2
7 Thermador CEM365 User manual Cooktop 2
8 Thermador CEP304 User manual Cooktop 0
9 Thermador CEM User manual Cooktop 0
10 Thermador CEP456 User manual Cooktop 2
11 Thermador CE365 User manual Cooktop 1
12 Thermador CEM365FS User manual Cooktop 0
13 Thermador CEP365 User manual Cooktop 0
14 Thermador CEP User manual Cooktop 1