ページ1に含まれる内容の要旨
Q QU UIIC CK K R RE EF FE ER RE EN NC CE E G GU UIID DE E
Hitachi Inverter
J300 Series
Hitachi Europe GmbH
ページ2に含まれる内容の要旨
Table of Contents Part 1 / 2 3 Description of J300 Display .................................................. 3 Operation procedure (example for the digital operator)............ 3 Setting extended functions ..................................................... 4 Protective Functions............................................................... 5 J300 data setting values............................................
ページ3に含まれる内容の要旨
5(6( 7 6723 5(6(7 2367 Protective Functions [FUNC key] ... This key switches 30.1 FUNC. between the parameter area, data The SJ100 series inverter will trip on overcurrent, overvoltage and undervoltage to protect the area, and extended function area. inverter.The output is shut down and the motor runs free. This condition is held until it is reset. HITACHI INVERTER Each time the key is pressed, the Trip Contents Display display changes as follows: J300 SERIES FUNC F 6 Overcurrent When the
ページ4に含まれる内容の要旨
(Continued from previous page) Standard Set Standard Set Display Function Display Function Setting Value Setting Value Wiring example: power terminals A 0 A94 Characteristic V/F curve setting 0 PID feedback signal location / I gain setting 0 0-constant torque 0-PID control not active 1,5 1,7 2 1-Terminal OI / 1 2-Terminal O / 1 1-M ~ n 2-M ~ n 3-M ~ n 3-Terminal OI / 10 4-Terminal O / 10 Power source 4-SLV 5-SLV + feedback A95 PID control set value setting 0 A 1 Motor
ページ5に含まれる内容の要旨
UPRWR 6KLHOGHG FDEOHV WUFRQRO KLHOGHG DEOHV 6 F External dimensions and terminal positions part 1/2 (part 2/2 on next page) smallest if they intersect at an angle of 90°. Cables susceptible to interference should therefore only intersect motor cables, intermediate HITACHI INVERTER circuit cables, or the wiring of a rheostat at right angles and never be laid parallel to them over larger distances. J300 SERIES Air Air QUICK REFERENCE GUIDE (Part 2/2) 5. The distance between an interference so
ページ6に含まれる内容の要旨
External dimensions and terminal positions part 2/2 (part 1/2 on previous page) TechnicalSpecifications 055 075 110 150 220 300 Technical Specifications 370 450 550 750 900 1100 Inverter J300- HFE4 HFE4 HFE4 HFE4 HFE4 HFE4 Inverter J300 HFE4 HFE4 HFE4 HFE4 HFE4 HFE4 - Air Loads having constant torque Loads having constant torque Maximum motor size in kW 5.5 7.5 11 15 22 30 Maximum motor size in kW 37 45 55 75 90 110 Digital operator Maximum motor 400V 9.0 11 16 22 33 40 Maximum motor 400V