ページ1に含まれる内容の要旨
Installation Instructions
NZ & AU
CG603 SERIES
CG903 SERIES
CG913 SERIES
599284 B 07.2006 NZ & AU
ページ2に含まれる内容の要旨
Safety & Warnings IMPORTANT! WARNING Read these instructions carefully before installing or using this product. Cut Hazard Please make this information available to the person responsible for installing the product Beware of sharp as it could reduce your installation costs. edges when handling stainless steel These products are registered: appliances. in New Zealand at www.ess.govt.nz and in Australia with AGA at www.gas.asn.au. Failure to use caution could result in injury or
ページ3に含まれる内容の要旨
Dimensions A B C J F H G E D CG603 series CG903 series CG913 series Product Width 578 914 914 A Depth 511 533 546 B Height 40 40 76 C Pan support 43 43 22 to Benchtop CG603 series CG903 series CG913 series Cutout Width 560 (558-562) 870 (846-882) 870 (860-882) D Depth 490 (485-495) 494 (478-501) 494 (486-524) E Radius R10 R10 R10 F 30 30 30 G 40 47 35 H Clearance to nearest 60 60 81 J combustible surface Note: All measurements given in millimetres (mm). Cutout dimensions are given as an ‘ideal
ページ4に含まれる内容の要旨
Clearances a b d g e f c a 600 mm minimum from top of trivet to rangehood. 750 mm minimum from top of trivet to overhead exhaust fan. (Fisher & Paykel splashbacks are 750 mm high). b 600 mm minimum from top of trivet to downward facing combustable surface. (450 mm minimum if protected by tiles or fire resistant materials). CG603 SERIES CG903 SERIES CG913 SERIES c Clearance from side edge of 130 mm 120 mm 80 mm product to any combustible surface d Clearance from rear edge of 100 mm 90 mm 90 m
ページ5に含まれる内容の要旨
Installation Instructions Standards Requirements Gas Supply Connection This cooktop is supplied set up for Australian and New Zealand Gas Installation Natural Gas but is suitable for installation Standards (AS5601, NZS 5261) require a with either Natural Gas or LPG. Refer to cooktop to be installed so that the surface relevant table for pressures and appropriate temperature of any nearby combustible orifice sizes. o surface will not exceed 65 C above ambient. Gas connection to the p
ページ6に含まれる内容の要旨
Installation Instructions Natural Gas The operation of the appliance, including the ignition system, must be tested For Natural Gas usage the gas supply is before installation is complete. connected to the regulator which is supplied If after following the instructions given, loose with a built in test point - 1kPa (4” WG) satisfactory performance cannot be and the inlet connection of 1/2 “ B.S.P. (male obtained, contact the local gas authority or your local Approved Service Agent for
ページ7に含まれる内容の要旨
Installation Instructions 12 Turn on main electrical supply and light the Minimum Setting or Turn Down burners. This has been set at the factory for NG but 13 Important! Reset the minimum setting may need adjusting for local conditions. (see ‘Minimum Setting or Turndown’). When converting to LPG, the minimum 14 Check all burners have good flame (see setting MUST be reset for each burner. fig.3,4,5). To adjust the minimum setting you will need a Ø 2.5 x 45 mm screwdriver. 1 Ignite the
ページ8に含まれる内容の要旨
Installation Instructions Gas Rate Summary Burners Natural Gas LPG Orifice size MJ/h@1 kPa Orifice size MJ/h@2.75 kPa CG603 Auxiliary Burner (RH front) 0.85 mm 3.6 MJ/h 0.55 mm 4.0 MJ/h Semi-Rapid Burner (LH & RH rear) 1.3 mm 8.5 MJ/h 0.8 mm 8.5 MJ/h Wok Burner (LF front) 1.75 mm 15 MJ/h 1.00 mm 13.5 MJ/h Rapid Burner (LH front) 1.55 mm 12 MJ/h 0.95 mm 12 MJ/h CG903 Auxiliary Burner (RH front) 0.85 mm 3.6 MJ/h 0.55 mm 4.0 MJ/h Semi-Rapid Burner (LH & RH rear) 1.3 mm 8.5 MJ/h 0.80 mm 8.5 MJ/h Fis