ページ1に含まれる内容の要旨
BOSCH
MAKERS WARRANTY
Cooktop
Model No: PCL 785 FAU
USER INSTRUCTIONS
INSTALLATION INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
This cooktop is for use with Natural and Propane gases
BOSCH
Leave these instructions with the owner
Part No: W1531
Version (Bosch) A
Booklet designed and produced by DESIGN MAXIM. (03) 0853 7491
ページ2に含まれる内容の要旨
Wiring diagram A. Switch B. Blue wire C. Brown wire D. Terminal E. Ignition module For service to this appliance please call an authorised Bosch Service agent service agent or register your fault by phoning us on the numbers listed below. Toll free Melbourne : 1300 30 70 37 (head office) Sales, Customer and Technical Service New Zealand: 0800 4BOSCH 0800 426 724 Sales and Customer Service Robert Bosch (Australia) Pty. Ltd. (Incorporated in Victoria) ABN 48 004 315 628 Victoria: Cnr. Centre & McN
ページ3に含まれる内容の要旨
Service Contents It is not always necessary to call the Service Centre. In Contents ....................................................... 3 Trouble shooting some cases, you may be able to solve the problem chart Safety considerations ...................................... 4 yourself. This table contains some useful information. Important: For your safety .......................................... 4 Only authorised personnel from the Service Centre What to do if you smell gas ..................
ページ4に含まれる内容の要旨
Safety considerations • If the information in this manual is not followed ex- Do’s For your safety Cleaning actly, a fire or explosion may result causing prop- • Once the appliance is cold, clean it with a sponge erty damage, personal injury or death. and soapy water. Remove any spills immediately. • Do not store articles on or against this appliance. This will avoid unnecessary effort later. • Do not store flammable materials near this appli- • Allow burners and trivets to cool down before clea
ページ5に含まれる内容の要旨
User instructions Use ‘High flame’ setting to bring the pan to the boil, 9. For pressure testing in excess of 3.5 kPa Boiling burners then adjust the flame between ‘High flame’ and ‘Low (1/2 psig) the appliance and its individual shut- flame’ to maintain the required pan temperature. off valve must be disconnected from the gas sup- ply piping system. Important: 10. Important The use of a cooktop leads to the production of heat and moisture in the kitchen. For this reason make sure When using a v
ページ6に含まれる内容の要旨
Operating instructions Installation This installation must conform with the following: Preparing to install Burner locations • Manufacturer’s Installation instructions • Local Gas Fitting Regulations • Municipal Building Codes, • AGA Installation Code for Gas Burning Appli- ances. (AS 5601AG 601) • S.A.A. Wiring Code • Local Electrical Regulations • Any other statutory regulations These built-in hobs are intended to be inserted in a benchtop cutout. Only an authorised person should connect the
ページ7に含まれる内容の要旨
ページ8に含まれる内容の要旨
Installation continued It should be expressly noted that we cannot accept Electrical: Connection any liability for direct or indirect damage caused by An electrical 10 amp socket needs to be within 1 m of wrong connection or improper installation. When the hotplate to allow electrical connection. The socket being repaired, the appliance must always be must remain accessible after installation of the appli- disconnected from the mains supply; if required, ance. notify our customer service. Impor