ページ1に含まれる内容の要旨
Installation, Service and User Instructions
Built-in gas cooktops
BERTAZZONI
DIMENSIONS: 36’’ (915 mm)(W) x 253/16’’ (640 mm)(D)
Models CB36500X [C3W0..U7X (2 or 5)A]
Models CB36600X [C3Y0..U7X(2 or 5)A]
IMPORTANT - PLEASE READ AND FOLLOW
-Before beginning installation, please read these instructions completely and carefully.
-Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. -Please
ページ2に含まれる内容の要旨
WARNING Read this instruction booklet before installing and using the appliance. The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance. The manufacturer reserves the right to make changes to its products when considered necessary and useful, without affecting the essential safety and operating characteristics. This appliance has been designed for non-professional, domestic use only. Warning: d
ページ3に含まれる内容の要旨
INSTALLATION MANUAL WORKTOP FRONTGUARD INSTALLATION INSTRUCTIONS In order to increase the clearance between front edge of the worktop and the burners for your safety it is recomended to install the worktop frontguard supplied with the appliance. For installation instructions follow the instructions indicated in the following figures 3
ページ4に含まれる内容の要旨
PROXIMITY TO SIDE CABINET INSTALLATION 1. This rangetop may be installed directly adjacent to existing 36" (91.5 cm) high base cabinets. IMPORTANT: The top grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertOP. 2.The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36" (91.5 cm) high. There must be a minimum of 6" (15.2 cm) side clearance from the rangetop to such combustible surface
ページ5に含まれる内容の要旨
COOKER HOOD INSTALLATION The bottom of the hood should be 25 ½ " (65 cm) min. to 31 ½ " (80 cm) above the countertop. Refer to the rangehood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. ELECTRICAL CONNECTION This unit is manufactured for a polarized, grounded 120 volt/60 Hz, 16 amp system. Electric power consumption is about 1 W. The minimum of 102 VAC is required for proper operation of gas ignition sys
ページ6に含まれる内容の要旨
Wiring diagram For freestanding gas range model CB36600X C3Y0..U7X(2 or 5)A CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. For freestanding gas range model CB36500X C3W0..U7X(2 or 5)A CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after
ページ7に含まれる内容の要旨
GAS CONNECTION All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. This range uses a 1/2" NPT (see fig. in this chapter for details of gas connections installations) inlet. Sealant on ali pipe joints must be resistive to LP gas. 1. Manual Shut-off Valve: This installer-supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and i
ページ8に含まれる内容の要旨
REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the appliance. Replacement parts are available from factory authorized parts distributors. CONVERSIONE TO DIFFERENT TYPES OF GAS Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig. Adaptation of the pressure regulator for use with different type of gas The pressure regulator supplied with the a
ページ9に含まれる内容の要旨
Models CB36600X [C3Y0..U7X(2 or 5)A] Adapting to different types of gas Burner Position Injector Gas Pressure Max Rate Min Rate By-pass diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm] Auxiliary Front R 0,92 NG 4” 3750 1098 900 264 Regulated 0,56 LP (Propane) 11” 3750 1098 900 264 0,29 Semi-Rapid Rear L & C 1,17 NG 4” 6000 1759 1500 439 Regulated Front C 0,73 LP (Propane) 11” 6300 18451500 439 0,36 Rapid Rear R 1,55 NG 4” 10400 20462500 732 Regulated 0,98 LP (
ページ10に含まれる内容の要旨
SERVICE & MAINTENANCE INSTRUCTIONS Service and maintenance only to be carried out by an authorised person To replace parts such as burners, valves and electric components, the appliance must be open removing the worktop. Note: if the valves must be replaced, first disassemble the ignitions switches wires. It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal between the body and the gas train. WARNING: After first installation of the
ページ11に含まれる内容の要旨
USING BURNERS A diagram is etched on the control panel above each knob which indicates which burner corresponds to that knob. Manual ignition: Manual ignition is always possible even when the power is cut off or in the event of prolonged power failure. Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star (large flame) and place a lit match up to the burner. Automatic electric ignition: Turn the knob that corresponds to th
ページ12に含まれる内容の要旨
WARNING: If the power is cut off, the burners can be lit with matches. The burners equipped with a safety thermocouple can only be lit when the knob is in the MAXIMUM position (large flame etching). CLEANING THE APPLIANCE: Never use abrasive cleaners Before cleaning the appliance it should be disconnected from the power supply. Cleaning the work surface: periodically clean the burner heads, the cast iron pan supports and the burner caps using warm water. Any spillage must always be remov