ページ1に含まれる内容の要旨
SERVICE MANUAL
(INTERNATIONAL)
IMPINGER CONVEYOR OVENS
MODEL SERIES 1000 & 1200
Lincoln Foodservice Products, LLC
1111 North Hadley Road
Fort Wayne, Indiana 46804
United States of America
Phone : (800) 374-3004
U.S. Fax: (888) 790-8193 • Int’l Fax: (260) 436-0735
Technical Service Hot Line
(800) 678-9511
www.lincolnfp.com
1000serviceexp REV: 1/5/07
ページ2に含まれる内容の要旨
TABLE OF CONTENTS TABLE OF CONTENTS..............................................................................................................................................2 SEQUENCE OF OPERATIONS 1002/1003...............................................................................................................3 SEQUENCE OF OPERATIONS 1106........................................................................................................................4 SEQUENCE OF OPERATIONS
ページ3に含まれる内容の要旨
SEQUENCE OF OPERATIONS 1002/1003 MODEL 1002 - 240VAC - 50HZ - NATURAL GAS MODEL 1003 - 240VAC - 50HZ - L.P. GAS POWER SUPPLY Electrical Power to be supplied to the Oven by a three conductor service. Black conductor is Hot Red conductor is Neutral Green conductor is Ground CONTROL BOX When the temperature in the Control Box reaches 120°F + AUTO COOL DOWN 3°, the Cooling Fan Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will interrupt power to the Cooling
ページ4に含まれる内容の要旨
TIME TEMP DISPLAY The Time/Temp Display is energized when the Fan Switch is closed, supplying 120 VAC to the primary of the 12.6 volt Transformer. The secondary output of the transformer, normally 13 to 14 VAC (depending on input), with a center tap, is supplied to terminals 1,2, and 3 of the Time/Temp Display. The center tap is terminal 2. The display works on a balanced input and center tap voltage to each leg must be 1/2 the total reading. The speed side of the Time/Temp. Display use
ページ5に含まれる内容の要旨
increase or decrease as the DC voltage from the board increases or decreases respectively. As the motor turns, it drives both the reducer gearbox and the Tach. Generator. The Tach. Generator is a DC voltage generator, which supplies a voltage to the DC motor control board and is used as a reference for maintaining a constant conveyor speed. TlME/TEMP DISPLAY The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 VAC to the primary of the 12.6 volt Transformer. Th
ページ6に含まれる内容の要旨
CONVEYOR DRIVE Closing the Fan Switch and the normally open Conveyor Switch supplies 120 VAC (S/N 100 to 4389) through a 3A Fuse, to the Motor Control Board. AC volts are converted to D.C. volts and are supplied to the Conveyor Motor at board terminals A1 and A2 through a D.P.D.T. Reversing Switch. Adjustment of the Speed Control Potentiometer (500 ohm, 10 turn) will change resistance at terminals S1, S2, and S3 varying the D.C. voltage to the Conveyor Motor. The speed of the Conveyor Motor
ページ7に含まれる内容の要旨
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The voltage from each leg of the Transformer' s secondary to the center tap should be one half of the secondary voltage BURNER CIRCUIT Closing the normally open Burner Switch supplies 220 VAC, through the gas pressure-proving switch, and through the Main Fan Air Pressure Switch, to the Ignition Control. The combustion motor relay is energized, its normally open contacts now close, supplying120 VAC to the combustion mot
ページ8に含まれる内容の要旨
Fan, and the Heat and Conveyor Switches. TRANSFORMER (12.6 Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC VAC) Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to 14 VAC) with a center tap, and supplies power to the Time/Temp Display. The voltage from each leg of the Transformer' s secondary to the center tap should be one half of the secondary voltage. HEAT CIRCUIT Closing the Fan Switch and the normally open Heat Switch supp
ページ9に含まれる内容の要旨
oven start and cool down relay. Its normally open contacts close, supplying 220 VAC to the Burner Switch and enabling the 20-minute Time Delay module. The 20-minute Time Delay module supplies 120 VAC to the oven fan motor relay, these normally open contacts now close, supplying 220 VAC to the Oven Fan Motor. TRANSFORMER(12.6V Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC AC) Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to
ページ10に含まれる内容の要旨
SEQUENCE OF OPERATIONS 1042 / 1043 / 1242 / 1243 MODEL 1042 - 240V - 50HZ - NATURAL GAS MODEL 1043 - 240V - 50HZ - L.P. GAS MODEL 1242 - 240V - 50HZ - NATURAL GAS/DUAL BELT MODEL 1243 - 240V - 50HZ - L.P.GAS/DUAL BELT POWER SUPPLY Electrical Power to be supplied to the Oven by a three conductor service. Black conductor is Hot Red conductor is Neutral Green conductor is Ground CONTROL BOX AUTO When the temperature in the Control Box reaches 120°F + 3°, the Cooling Fan COOL DOWN Thermo
ページ11に含まれる内容の要旨
TIME/TEMP The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 DISPLAY(S/N Q14790 & VAC to the primary of the12.6 volt Transformer. The secondary output of the Below, 1200 series S/N transformer, normally 13 to 14 VAC (depending on input), with a center tap, is Q14973 & Below, 1000 supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is series) terminal 2. The display works on a balanced input and center tap voltage to each leg must be 1/2
ページ12に含まれる内容の要旨
SCHEMATIC / 1002, 1003 12 Impinger I -–1000 Series Service Manual - International
ページ13に含まれる内容の要旨
SCHEMATIC / 1006 TO SERIAL NUMBERS Q14279 Impinger I -–1000 Series Service Manual - International 13
ページ14に含まれる内容の要旨
SCHEMATIC / 1028, 1029, S/N Q19071 & BELOW 14 Impinger I -–1000 Series Service Manual - International
ページ15に含まれる内容の要旨
SCHEMATIC / 1028, 1029, S/N Q19078 & ABOVE Impinger I -–1000 Series Service Manual - International 15
ページ16に含まれる内容の要旨
SCHEMATIC / 1030, TO S/N Q17170 16 Impinger I -–1000 Series Service Manual - International
ページ17に含まれる内容の要旨
SCHEMATIC / 1030, S/N Q17171 & ABOVE Impinger I -–1000 Series Service Manual - International 17
ページ18に含まれる内容の要旨
SCHEMATIC / 1032. S/N Q19077 & BELOW 18 Impinger I -–1000 Series Service Manual - International
ページ19に含まれる内容の要旨
SCHEMATIC / 1032, S/N Q19078 & ABOVE Impinger I -–1000 Series Service Manual - International 19
ページ20に含まれる内容の要旨
SCHEMATIC / 1033, 1034, 1046, 1047 20 Impinger I -–1000 Series Service Manual - International