ページ1に含まれる内容の要旨
203365A 120 Vac to 220/240 Vac
Conversion Kit For
Electronic Air Cleaners
2. Check the ratings given in the instructions and on
Application
the product to make sure the product is suitable for your
application.
The 203365A Conversion Kit changes the 120 Vac,
3. Installer must be a trained, experienced service
60 Hz to 220/240 Vac, 50/60 Hz. The kit includes a trans-
technician.
former and two screws. The line cord on the air cleaner
4. After installation is complete, check out product
must be ch
ページ2に含まれる内容の要旨
NOTE: Be sure the transformer terminals are located on the side away from the power supply. See Fig. 2. Fig. 2—Mount and wire transformer. 7. Use the two provided screws to secure the trans- former to the power box. WIRE TRANSFORMER TO POWER SUPPLY (See Fig. 2) 1. Remove black wire from power supply P1 terminal and place it on one of the transformer terminals. 2. Connect the transformer black lead to the power P3 supply P1 terminal. 3. Remove brown wire from power supply P2 terminal and place it
ページ3に含まれる内容の要旨
Fig. 3—Internal schematic for electronic air cleaner with 203365A Conversion Kit. BLACK COLLECTOR TEST RED IONIZER BUTTON RED CONTACT BOARD 5 BLACK BLACK POWER SUPPLY P3 BLACK P4 J2 P5 2 P12 ORANGE 2 J7 GREEN P21 4 P14 3 GRAY 1 4 BROWN P2 P18 P17 P1 VIOLET TERMINAL STRIP BLACK FRONT BACK BLACK 1 1 W4 W2 W1 W3 2 BLACK TO 2 W8600E 1 WALL 3 3 3 PANEL 4 4 BLACK BLACK AIR FLOW SWITCH BOARD 1 INTERLOCK SWITCH. 6 2 OUTPUT REDUCTION JUMPER. L1 L2 3 AIRFLOW SWITCH DISABLE JUMPER. 220/240 VAC 4 RE
ページ4に含まれる内容の要旨
TOOLS AND EQUIPMENT Checkout Troubleshooting the electronic air cleaner requires: • Needle nose pliers for stringing ionizer wires and inserting edge connectors. WARNING ! • Test meter. ELECTRIC SHOCK HAZARD. CAN CAUSE PERSONAL INJURY OR NEON LIGHT (On Power Box) EQUIPMENT DAMAGE. The neon light is powered through the power supply and The following procedures expose hazardous live is on when the power supply output voltage is normal. parts. Disconnect from power supply between checks and proceed
ページ5に含まれる内容の要旨
Fig. 4—Troubleshooting air cleaners with solid-state performance indicator. START TO USE THIS CHART: MAKE SURE ELECTRONIC 1. FOLLOW THE STEPS IN ORDER, DO NOT SKIP AROUND. CELL(S) ARE CLEAN, DRY 2. EACH TIME YOU ISOLATE AND FIX A PROBLEM, AND PROPERLY INSTALLED. MAKE SURE PREFILTER(S) GO BACK TO START. 3. REPEAT ALL THE STEPS UNTIL THE AIR CLEANER ARE IN CABINET SLOT CHECKS OUT OK. FARTHEST FROM FURNACE. TURN ON ELECTRONIC AIR CLEANER AND SYSTEM FAN. PUSH TEST BUTTON YES REPLACE LIGHT/
ページ6に含まれる内容の要旨
Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9 QUALITY IS KEY Printed in U.S.A. 6