13 SEER Mini Split Air Conditioner
with Heat Pump and Back up Electric Heat Strip
KFTHP-12-ID/KFTHP-12-OD
KFTHP-18-ID/KFTHP-18-OD
KFTHP-24-ID/KFTHP-24-OD
CM
C US
T
3 1 1 9 2 3 3
E
E
T
D
N
I
ページ2に含まれる内容の要旨
CAUTION All units must be installed by a licensed contractor or technician. Installation must be in accordance with this manual,NEC,State and Local Codes. Otherwise unit warranty will be void and serious damage to person and/or property may occur. Read all instruction manuals thoroughly before attempting installation. The Manufacturer shall NOT be liable for any damages or loss due to improper installation or operation or natural disasters. Do not power the unit until all wiring,refrigerant t
ページ3に含まれる内容の要旨
1 1Safety Precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure to follow this instruction. WARNING! DANGER! CAREFUL! Pay Attention. Remove the power source plug from a socket. Warning: Incorrect handling could cause a serious Grounding is essential. hazard, such as death, serious injury, etc. Keep the power supply Do not use the power circuit breaker or plug supply circuit breaker or from dirt. Connect the Use correct power supply in accordance with the
ページ4に含まれる内容の要旨
1 1 Identification of Parts Indoor Unit Air Intake Front Panel Emergency Panel Display Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Charcoal Filter (optional) Electrostatic Filter (optional) Air Filter Remote Control Air Intake Outdoor Unit Pipes and Power Connection Cord Drain Hose Note: Condensate water drains at COOLING or DRY operation. Air Outlet The figures in this manual are based on the external view of a standard model. Consequently, the sh
ページ5に含まれる内容の要旨
1 1Identification of Parts Operating and Display Temperature display Display of environm- Run Indicator Timer Indicator ental temperature or It is on during It lights up during setting temperature operation. the set time. Power Indicator Sleep Indicator It lights up when It lights up during the power supply is on. set sleep function The above operating sketch map is suitable for Z BG series. Signal Receives Temperature display(optional) Receive signal from the Display of environmental tem-
ページ6に含まれる内容の要旨
1 1 Remote Control Remote Control The remote control transmits signals to the system. ON/OFF button Signal Transmitting Window Used to start and stop operation . Transmits signals to the system. TIMER button Setting Display Used to select TIMER operation. UP button (TOO COOL button) Used to increase the set room temperature (60 f ~87 f) and time(0.5~24h or 1~12h ). DOWN button (TOO WARM button) Used to decrease the set room temperature and time. SLEEP button QUIET Used to set or cance
ページ7に含まれる内容の要旨
1 1 Remote Control Remote Control Some remote control s display: Feel Cool Dry Fan Heat SLEEP TIMER ON TMIER OFF FEEL A U T O Timer HIGH C COOL C off Tim e r M I D D R Y h o n LOW FAN h HEAT S W I N G Auto Low Mid High Sleep Swing Style.3 Style.1 Style.2. FAN F E E L SPEED AUTOQUIET C O O L AIR P O W E R F U L SWING D RY C A U T O h r FA N DELAY H E AT ON OFF ON HEALTHY TIMER Style.5 Style.4 Note:The above remote control is only for reference, subject to the actual unit. When inserting the
ページ8に含まれる内容の要旨
FEEL T M E RO N I COO L AUTO S WI NG SLEEP TMEI R O FF HI GH DR FA YN HEAT MLE O DW SLEEP F AN T IMER SW IN G M O D E O N / OF F SLEEP F E EL AU TO HIGH E L TI MER ON TM IE R OFF CO O L D R Y M D FA N OW H E A T S WIN G SLEEP FAN TIMER S W ING M O D E O N / O F F TIMER ON TM IER OFF FEEL AUTO HIGH DRY MED FAN LOW HEAT S WIN G SLEEP FAN TIMER S W ING M O D E O N /O F F SLEEP COOL 1 1 Remote Control Remote Control Please slide and remove the cover. How to Insert the Batteries 1 Remove the batter
ページ9に含まれる内容の要旨
3 Operation Instructions 1 1 FEEL mode operation procedure Operates by selecting automatically the operation mode(HEAT,DRY,FAN,COOL)depending on the room temperature during staring. With the remote control pointing toward the air conditioner. Turning on ON/OFF Press button, when the appliance receives the 1 signal, the RUN indicator of the indoor unit lights up. SLEEP TIMER ON TMIER OFF FEEL AUTO COOL HIGH DRY MID FAN LOW When the unit is not at FEEL mode. HEAT SWING Selecting FE
ページ10に含まれる内容の要旨
Operation Instructions 1 1 TIMER mode It is convenient to set the timer on with TIMER button when you go out in the morning to achieve a comfortable room temperature when you get home. You can also set timer off at night to enjoy a good sleep. When the Remote When the Remote Control is ON,press Control is OFF,press the TIMER button to the TIMER button to set set a switch-on timer, a switch-on timer,press press again,the setting again,the setting will be will be cancel. cancel. Press UP
ページ11に含まれる内容の要旨
Dangerous! Electric shock! 1 1Maintenance Air filter maintenance Front panel maintenance It is necessary to clean the air filter after using Turn off the appliance it for about 100 hours. first before disconnecting Clean it as follows: Cut off the from power supply. power supply Stop the appliance Grasp position "a" and remove the and pull outward to air filter. remove the front panel. 1.Open the front panel. Wipe with a soft and 2.Press the handle of the filter gently dry cloth. Use a
ページ12に含まれる内容の要旨
1 1 Protection Noise pollution Operating condition The protective device maybe trip and stop the appliance in the cases listed below. Install the air conditioner at a place that can bear its weight in order to operate Outdoor air temperature is over 75 f more quietly. HEATING Outdoor air temperature is below -19 f (-5 f for inverter models,it's optional) Install the outdoor unit at a place where the air discharged and the operation noise Room temperature is over 80 f would not annoy your
ページ13に含まれる内容の要旨
1 1Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Analysis Trouble If the plug is not properly plugged. If batteries in the remote controller exhausted. Does not run If the protective device works to protect the appliance. If the protector trip or fuse is blown. Are the intakes and outlets of the air conditioner No cooling or blocked heating air Is the temperature set properly Is the air filter dirty? If strong interference(fro
ページ14に含まれる内容の要旨
air outlet distance from the wall should be over 6 feet 1 1Installation Instructions Installation Diagram Distance from ceiling should be over 6” Distance from wall should be over 6”” Distance from the wall should be over 6” Distance from floor should be over 6 feet over 20 Air intake distance from the wall Air intake distance from Should be over 12” the wall should be over 12” over 12” N NO OT TE E Above figure is only a simple presentation of the unit, it may not match the external appearan
ページ15に含まれる内容の要旨
Connecting of the Cabble b st l cation Select the e o Installation Instructions 1 1 Front panel Wiring between the indoor and outdoor units: Terminal (inside) 1) Remove the PCB cover from the indoor unit; COVER COVER 2) Refer to the wiring diagram attached to indoor unit when connecting cords to indoor unit terminals; A side (before connect) 3) Reinstall the PCB cover. Be sure that side B B side (after connect) is facing outside. Cabinet Location for Installing Indoor Unit
ページ16に含まれる内容の要旨
1 1 Installation Instructions Indoor Unit Installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting. plate horizontally with a horizontal ruler or dropping line. Drill holes of 1" in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws. Inspect if the mounting plate is well fixed. Then dril
ページ17に含まれる内容の要旨
1 1Installation Instructions N NO OTE TE Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type The temperature of refrigerant circuit Thermal insulation will be high, please keep the interconnection cable away from the copper tube. Piping Thermal Insulation: Large pipe Thermal insulation a. Place the drain hose under the piping. tube b. Insulation material uses polythene foam over 3/8" in
ページ18に含まれる内容の要旨
1 1 Installation Instructions 4. Connecting of the Cable Indoor Unit Front panel Connect the power connecting cord to the indoor unit Terminal (inside) by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection. Cabinet Note: For some models, it is necessary to remove the cabinet to connect to indoor unit terminal. Indoor unit Chassis Outdoor Unit 1). Remove the access door from the unit by loosening the screw. Connect the w
ページ19に含まれる内容の要旨
1 1Installation Instructions Outdoor Unit Installation 1.Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order to protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then Washer connect a drain hose to the port as the right figure shown. Drain hose Drain port (prepare
ページ20に含まれる内容の要旨
1 1Installation Instructions Interconnection Cable (1)Take off the cover for Interconnection cable of outdoor unit. (2)Take off the block for Interconnection cable, then put the core of the power wire to the terminal and fix it according to the diagrams pasted to indoor and outdoor unit separately. (3)Fix the accessory cable with the Interconnection cable block. (4) Confirm the fixing of the accessory cable is ok. (5)Fix the cover for Interconnection cable on. Diagram for installation o