ページ1に含まれる内容の要旨
- Cooling
- Heating
- Dehumidifying
- Fan
Please read Owner’s Manual
carefully before operating the
unit.
1
ページ2に含まれる内容の要旨
TABLE OF CONTENTS INTRODUCTION...........................................................................................................................................3 IMPORTANT SAFEGUARDS.......................................................................................................................3 PACKAGE CONTENTS................................................................................................................................4 IDENTIFYING THE PARTS ............
ページ3に含まれる内容の要旨
INTRODUCTION Thank you for purchasing the Soleus Air MA-9000AH portable air conditioner. This unit is designed to improve living and working comfort by providing cooling, dehumidifying and fan functions with only minimum installation required. With its whisper quite operation and attractive design, you will enjoy the convenience and comfort that this unit provides for many years to come. When operating as an air conditioner, this unit is designed for spot cooling or cooling for a room
ページ4に含まれる内容の要旨
PACKAGE CONTAINS: 1 Portable Air Conditioner 1 Air Exhaust Duct 1 Window Kit (2 Sliding Panels) 1 Window Kit Adapter 1 Remote Controller 2 AAA Batteries 1 User Manual IDENTIFYING THE PARTS Front View 4
ページ5に含まれる内容の要旨
Exhaust Duct Window Kit 5
ページ6に含まれる内容の要旨
ASSEMBLY REQUIREMENTS 1) Exhaust Duct When you use the unit as an air conditioner, the hot exhaust air must be directed out of the room. The exhaust duct is required to allow the hot air out of the room through a window. DO NOT INSTALL OR USE THE EXHAUST DUCT WHEN THE UNIT IS OPERATED AS A DEHUMIDIFIER OR FAN. Slide “Unit Terminal End” of the exhaust connector completely over the “Hot Air Outlet Grill” on the rear of the unit. Plastic grooves are located on the hot air outle
ページ7に含まれる内容の要旨
NOTE: In order to achieve maximum room cooling efficiency, the exhaust duct should remain as short and straight as possible. To further shorten the exhaust hose, first unthread either exhaust duct adapter clockwise to remove it. Then cut the hose to desired length. It is not recommended to increase the manufacturer’s length of the exhaust hose. This may reduce the cooling efficiency or damage the unit. 2) Window Kit Installation a. Open window approximately 5 inches (13 cm) b. A
ページ8に含まれる内容の要旨
Control Panel Functions 1. Power On/Off Control Starts or stops the unit 2. Temperature Setting Control Select the desired temperature setting by pressing either the or key. It is recommended to set the temperature before selecting the Mode Control. 3. Mode Control Select the functions of the unit for: a. Air Conditioning Mode (COOL) b. Dehumidifying Mode (DRY) c. Heating Mode (HEAT) 4. Fan Speed Control Select the fan speed for: a. Hig
ページ9に含まれる内容の要旨
a. When the unit is On, press “Timer” Button, then press the “Time” button until the desired number of hours is displayed in the lower right corner of the display window. The unit will automatically power Off once the selected number of hours has elapsed. b. When the unit is Off, press “Timer” Button, then press the “Time” button until the desired number of hours is displayed in the lower right corner of the display window. The unit will automatically power On once the selected numbe
ページ10に含まれる内容の要旨
a. Be sure that the drain bucket is properly placed in the unit. If the drain bucket is not properly secured in the unit, the red “Water Full” light located on the front panel will blink and the unit will not begin dehumidifying. b. If exhaust duct is attached, remove it from the rear of the air conditioner c. Plug the Power Cord to the power outlet. d. Turn on the unit by pressing the On/Off Button on the control panel. e. Press the Mode Button until “DRY” appears on the LCD disp
ページ11に含まれる内容の要旨
OPERATION USING REMOTE CONTROLLER REMOTE CONTROLLER 1. To Set the Clock Open the back cover of the remote controller and insert two AAA batteries. When batteries 11
ページ12に含まれる内容の要旨
are installed or replaced, the clock is set to 12:00AM. To set present time: 2. Cooling Operation a. Be sure that the drain bucket is properly placed in the unit. If the drain bucket is not properly secured, the red “Water Full” light located on the front panel will blink and the unit will not begin cooling. b. Be sure the exhaust duct properly installed. Refer to page 6 for exhaust duct installation. c. Plug the Power Cord to the power outlet. d. Press the ON/OFF key to
ページ13に含まれる内容の要旨
a. Plug the Power Cord to the power outlet. b. Turn on the unit by pressing the On/Off Button on the remote control. c. Press the Mode Button until “Heat” appears on the LCD display. d. Press the Temperature Button or until the desired room temperature o o o o appears on the LCD. The temperature ranges from 63 F-88 F (17 C-31 C). NOTE: When the unit is operating in “HEAT” mode, the exhaust duct is not required. 4. Dehumidifying Operation a. Be sure that
ページ14に含まれる内容の要旨
desired number of hours is displayed in the LCD. The unit will automatically power Off once the selected number of hours has elapsed. b. When the unit is Off, press “Timer” Button, then press the “Hour” button until the desired number of hours is displayed in the LCD. The unit will automatically power On once the selected number of hours has elapsed. NOTE: The timer function must be manually reset before each automatic start or stop. CONDENSATE WATER
ページ15に含まれる内容の要旨
is discharged by gravity through a drainage tube (12” length) to either an external hose (not included) or to a condensate water pump device (not included). When the unit is operating on continuous drainage mode, it can operate continuously without periodic stops to empty the water bucket. To allow continuous drainage: a. Remove the water bucket from the cabinet. b. Find the tube hanging beside the water bucket inside of the cabinet. c. Remove the plug from the end of the tube.
ページ16に含まれる内容の要旨
1) Clean or Replace Filter a. If the air filter is clogged, the airflow volume will decrease, reducing cooling efficiency. It is recommended to clean the filter once a month or as needed. b. Push down the tab on the filter cover and pull outwards to remove the entire filter and cover. c. Carefully remove the air filter from the filter cover. d. Wash the air filter by immersing it gently into warm water with a mild detergent. e. Rinse the f
ページ17に含まれる内容の要旨
PROBLEM POSSIBLE CAUSE REMEDY Unit does not operate Unit is unplugged Securely plug receptacle into the power outlet Drain bucket is full Empty water bucket Water bucket not installed Completely insert water bucket correctly Air exhaust is clogged Remove obstruction from exhaust hose Timer is on Cancel the timer Unit does not cool room There is a heating source in the Turn down or off the other room heating source Temperature setting is too high Lower temperature setting Air filter i
ページ18に含まれる内容の要旨
MODEL MA-9000AH COOLING CAPACITY 9000 BTU/hr HEATING CAPACITY 1100 W DEHUMIDIFYING CAPACITY 88 Pints/Day POWER COOLING/HEATING 1120W/1350W DEHUMIDIFYING 1100W AIR FLOW VOLUME 180 CFM POWER SOURCE VOLTAGE 115 V 60 HZ RATED CURRENT 11.5 AMP COOLING 11.7 AMP HEATING SOUND PRESSURE LEVEL 54 db NET WEIGHT 77 Lbs DIMENSIONS BODY 17¼ x 14¾ x 32½ Inches PACKAGE 26½ x 18½ x 34½ Inches REFRIGERANT R22 WATER BUCKET VOLUME 4L NOTE: 1) The above cooling capacity is measured at ambient
ページ19に含まれる内容の要旨
WARRANTY ONE YEAR LIMITED WARRANTY Soleus International Inc. warrants the accompanying MA-9000AH Soleus Air air conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada. If the air conditioner exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of charge within