ページ1に含まれる内容の要旨
VitalScreen 17.4" Display
VS17.4SXAD / CM17.4SXAD
OPERATIONS MANUAL
www.planar.com
ページ2に含まれる内容の要旨
Planar Systems, Inc. © 2003. All rights reserved. Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. Planar provides this information as reference only. Reference to other vendors’ product does not imply any recommendation or endorsement. This document contains proprietary information protected by copyright. No part of this manual may be reproduced by
ページ3に含まれる内容の要旨
iii Regulatory Compliance VitalScreen CSR This display has been tested and found to comply with IEC/EN 60601-1 and IEC/EN 60601-1-2 standards, and is certified to meet medical standard C22.2 No. 601.1-M1990 (C US Mark). The medical display, in addition to meeting medical requirements, has been tested and found to comply with the limits for Federal Communications Commission (FCC) Class B computing devices in a typically configured system since many medical offices are located in resid
ページ4に含まれる内容の要旨
iv In summary, Planar Systems, Inc. is CE-marking these displays under the Medical Device Directive, which establishes compliance to the basic medical safety standards. However, EMC compliance can only be accomplished in the configured medical device or system and is the responsibility of the device or system manufacturer. Planar has the necessary documentation such as IEC 60601-1 notified body and other third-party test reports and certifications, a risk/hazard analysis, an essen
ページ5に含まれる内容の要旨
v FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
ページ6に含まれる内容の要旨
ページ7に含まれる内容の要旨
vii Contents About This Manual .............................................................. ix Product Information............................................................. x 1 The VitalScreen 17.4" Display........................................... 1 VitalScreen CSR ...................................................................... 2 VitalScreen CR......................................................................... 2 Distinguishing the Displays .............................
ページ8に含まれる内容の要旨
ページ9に含まれる内容の要旨
ix About This Manual Congratulations on your purchase of the VitalScreen display! This operations manual will help you set up, use, and maintain the VS17.4SXAD or CM17.4SXAD model properly. Retain this manual for future reference. Read this section carefully to learn how to handle the display safely and clean it correctly. It explains the symbols used on the products and the conventions used in this manual. Chapter 1 provides an overview of the VitalScreen display. It lists t
ページ10に含まれる内容の要旨
x | Product Information Product Information Safety Instructions Store the display in its original shipping carton when it is not in operation for extended periods of time. Also use the original packing materials and carton when shipping the display. • Do not place the display near a window. Exposing the display to rain, water, moisture, or constant direct sunlight can damage it. • Do not place anything on top of the display-to-computer signal cord. Make sure the cord is placed where
ページ11に含まれる内容の要旨
Product Information | xi Cleaning Instructions The VitalScreen display will continue to operate while being cleaned in a fashion normal for a hospital environment. This means cleaning the display with a damp, mild soapy cloth. The VitalScreen withstands nonabrasive cloths and cleaning solutions used in hospital for like equipment. This cleaning typically includes warm water and mild detergent for all surfaces or 70 percent isopropyl alcohol for the touchscreen surface. Possible cle
ページ12に含まれる内容の要旨
xii | Product Information Symbol Explanations This table explains the symbols appearing on the display or power supply adapter. This symbol… Indicates… Proof of conformity to applicable European Economic Community Council directives and two harmonized standards published in the official journal of the European Communities. The product has been tested to specific requirements of medical or ITE device standards. If this mark appears with the indicators “C” and “US,” the product is
ページ13に含まれる内容の要旨
The VitalScreen 17.4" Display The architecture of the VitalScreen CSR and VitalScreen CR displays incorporate an active matrix liquid-crystal display (AMLCD) panel that produces a bright, high-contrast image with low radiation emission. This technology greatly reduces the radiation-related health concerns associated with cathode-ray tube (CRT) monitors. Each VitalScreen is a high-resolution color display designed to be versatile and easy to use. The display accepts either ana
ページ14に含まれる内容の要旨
2 | The VitalScreen 17.4" Display VitalScreen CSR This display has been designed, tested, and certified for use within the patient vicinity. It has lower electric discharge, thus reducing the likelihood of electric shock. The display is certified to UL-2601, IEC 60601-1, and other representatives of the most stringent electric discharge certifications available. In addition, the interface buttons on the front panel are sealed by a plastic membrane, allowing simpler and safer clean
ページ15に含まれる内容の要旨
The VitalScreen 17.4" Display | 3 Selecting a Workspace Before unpacking the display, prepare a suitable workspace. You need a stable and level surface near a grounded wall outlet in an area that is relatively free of glare from sunlight or other sources of bright light. The display is cooled by natural convection. For best performance, do not block the cooling vents. Unpacking the Display While unpacking the display, inspect it and other package contents for shipping damage tha
ページ16に含まれる内容の要旨
4 | The VitalScreen 17.4" Display Identifying the Components The VitalScreen CSR and VitalScreen CR displays provide easy access to all controls and peripheral ports. The following illustrations of the screen and the front and back panels identify the display controls and ports. 17.4" LCD screen LCD screen A 17.4-inch diagonal AMLCD. The screen supports most display standards from 640 x 480 VGA to 1280 x 1024 SXGA. VS17.4SXAD / CM17.4SXAD (020-0168-00B)
ページ17に含まれる内容の要旨
The VitalScreen 17.4" Display | 5 Front panel Power switch / Dual function button to control display Onscreen display power and access the OSD menu. Press this button for 2 seconds to turn the display ON or OFF. When the display is ON, press this button once to access the OSD menu. Function buttons UP and DOWN arrows to navigate the OSD menus. When the OSD menu displays, press these buttons to select a control function. Adjustment buttons Controls to adjust the selected
ページ18に含まれる内容の要旨
6 | The VitalScreen 17.4" Display Back panel Locking 4-pin power connector Connect the low-voltage cable from the power adapter to this port. USB downstream ports (2) Connect peripherals (e.g., keyboard, 2 mouse) to these ports, if desired. USB upstream port (1) Connect the USB cable from the 3 computer to this port, if desired. Audio input jack Connect the system audio lineout to this port to listen to the system audio 4 on the display stereo speakers. Touchscreen (DB-9 ser
ページ19に含まれる内容の要旨
Installing the Display To install the VitalScreen CSR or VitalScreen CR display, first connect the power supply unit. Next, connect the video cable. Then choose whether to connect optional stereo speakers and touch screen. Safety Precautions Follow these safety precautions when connecting the display. • Plug the power adapter into a grounded power outlet. • Use a surge protector between the AC adapter and the electrical wall outlet to prevent sudden current variations from
ページ20に含まれる内容の要旨
8 | Installing the Display Connecting the Display to the System 1 Turn off power to the computer, camera, or other output source, and to the display. 2 Connect the appropriate video cable from the display to the video port on the output source. 3 Make sure the video cable connector is securely connected to the video port on the output device. 4 Turn on the display first, then turn on the output device. 5 Set the output device to a supported resolution, if applicable. (See “Sup