ページ1に含まれる内容の要旨
OUTDOOR UNIT
No. OBH498
HFC
utilized
SERVICE MANUAL
R410A
Wireless type
Models
MUZ-FD09NA
U1
MUZ-FD09NA-
MUZ-FD12NA
U1
MUZ-FD12NA-
Indoor unit service manual
MSZ-FD•NA Series (OBH497)
CONTENTS
1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 3
3. SPECIFICATION ················································ 4
4. OUTLINES AND DIMENSIONS ························ 6
5. WIRING DIAGRAM ············································ 7
6. REFRIG
ページ2に含まれる内容の要旨
2
ページ3に含まれる内容の要旨
1 TECHNICAL CHANGES MUZ-FD09NA MUZ-FD12NA U1 MUZ-FD09NA - U1 MUZ-FD12NA - 1. New model 2 PART NAMES AND FUNCTIONS MUZ-FD09NA MUZ-FD12NA Air inlet Piping Drain hose Air outlet Drain outlet 3 3
ページ4に含まれる内容の要旨
3 SPECIFICATION Outdoor unit model MUZ-FD09NA MUZ-FD12NA Cooling 1 Btu/h 9,000 (2,800~9,000) 12,000 (2,800~12,000) Capacity Rated (Minimum~Maximum) Heating 47 1 Btu/h 10,900 (3,000~18,000) 13,600 (3,000~21,000) Capacity Rated Heating 17 2 Btu/h 7,700 8,300 Cooling 1 W 650 (160~650) 960 (160~960) Power consumption Rated (Minimum~Maximum) Heating 47 1 W 750 (150~2,400) 980 (150~2,400) Power consumption Rated Heating 17 2 W 1,7
ページ5に含まれる内容の要旨
Test condition 3, 4 Indoor air condition Outdoor air condition Mode Test ARI Dry bulb (°F) Wet bulb (°F) Dry bulb (°F) Wet bulb (°F) "A" Cooling Steady State 80 67 95 (75) at rated compressor Speed "B-2" Cooling Steady State 80 67 82 (65) at rated compressor Speed SEER "B-1" Cooling Steady State 80 67 82 (65) (Cooling) at minimum compressor Speed Low ambient Cooling Steady State 80 67 67 (53.5) at minimum compressor Speed Intermediate Cooling Steady State 80 67 87 (69) at Interme
ページ6に含まれる内容の要旨
4 in. or more 14 in. or more 4 OUTLINES AND DIMENSIONS Unit: inch MUZ-FD09NA MUZ-FD12NA REQUIRED SPACE Basically open 4 inch or more without any obstruction in front 15-3/4 Drain hole 1-5/8 and on both sides of the unit. Air in Air in 1-9/16 Air out 2- 3/8 13/16 Oval hole 7/8 29/32 11-1/4 17/32 Open two sides of left, right, or rear side. handle Liquid pipe :1/4 (flared) Gas pipe :3/8 (flared) 11-29/32 6-23/32 5-15/16 19-11/16 31-1/2 2-23/32 6 6 8 in. or more 4 in. or more 21-5/8 11-1/
ページ7に含まれる内容の要旨
5 WIRING DIAGRAM MUZ-FD09NA MUZ-FD12NA 7 7
ページ8に含まれる内容の要旨
6 REFRIGERANT SYSTEM DIAGRAM Unit:inch MUZ-FD09NA MUZ-FD12NA 4-way valve Refrigerant pipe ø3/8 (with heat insulator) Muffler Outdoor heat exchanger temperature Stop valve thermistor (with service port) RT68 Outdoor Muffler Discharge heat Flared connection exchanger temperature Service thermistor port RT62 Ambient Compressor Service temperature port thermistor RT65 Defrost thermistor RT61 Capillary tube O.D. 0.118 × I.D. 0.071 × 23-5/8 (ø3.0 × ø1.8 × 600) Strainer #100 Expansion Flared connection
ページ9に含まれる内容の要旨
7 DATA MUZ-FD09NA MUZ-FD12NA 7-1. PERFORMANCE DATA 1) COOLING CAPACITY Indoor air Outdoor intake air DB temperature (˚F) Model IWB 75 85 95 105 115 (˚F) TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC 71 11.0 6.9 0.58 10.3 6.5 0.63 9.7 6.1 0.68 9.0 5.6 0.72 8.3 5.2 0.75 MUZ-FD09NA 67 10.4 7.9 0.55 9.7 7.4 0.60 9.0 6.8 0.65 8.4 6.4 0.69 7.7 5.8 0.72 63 9.8 8.8 0.52 9.1 8.1 0.58 8.5 7.6 0.62 7.7 6.9 0.66 7.0 6.3 0.69 71 14.7 8.8 0.85 13.7 8.2 0.94 12.9 7.7 1.01 12.0 7.2 1.06 11.0 6.6 1
ページ10に含まれる内容の要旨
Indoor intake air WB temperature (°F) Indoor intake air WB temperature (°F) 7-2. PERFORMANCE CURVE Cooling MUZ-FD09NA MUZ-FD12NA SHF at rating condition = 0.76 SHF at rating condition = 0.73 Airflow = 307 CFM Airflow = 350 CFM 13 15 14 12 13 11 10 12 9 11 71 71 10 67 8 67 63 9 63 7 1.2 71 71 0.7 67 1.1 67 63 1.0 63 0.6 0.9 0.8 0.5 0.7 65 75 85 95 105 115 65 75 85 95 105 115 Outdoor intake air DB temperature (°F) Outdoor intake air DB temperature (°F) Heating MUZ-FD09NA MUZ-FD12NA Airflow = 381
ページ11に含まれる内容の要旨
7-3. CONDENSING PRESSURE Cooling Data is based on the condition of indoor humidity 50 %. Air flow should be set to High speed. MUZ-FD09NA (PSIG) 580 540 (PSIG) 180 500 175 170 86 460 86 165 80 75 160 420 70 80 155 150 380 145 75 140 340 70 135 130 300 125 120 260 68 70 75 80 85 90 95 100 105(°F) 68 70 75 80 85 90 95 100 105(°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FD12NA (PSIG) 580 540 (PSIG) 180 500 175 86 170 80 460 75 165 86 70 160 420 155 80 150 380 145 140 340 75 135
ページ12に含まれる内容の要旨
Heating Data is based on the condition of outdoor humidity 75 %. Air flow should be set to High speed. Data is for heating operation without any frost. MUZ-FD09NA (PSIG) (PSIG) 400 380 170 75 70 75 360 160 65 70 340 65 150 320 140 300 130 280 120 260 110 240 58Hz 58Hz 100 220 90 200 80 180 70 160 140 60 14 20 25 30 35 40 45 50 55 60 65 70(°F) 14 20 25 30 35 40 45 50 55 60 65 70(°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FD12NA (PSIG) (PSIG) 400 380 170 75 75 360 70 160 65 70
ページ13に含まれる内容の要旨
7-4. STANDARD OPERATION DATA Model MSZ-FD09NA MSZ-FD12NA Item Unit Cooling Heating Cooling Heating Capacity Btu/h 9,000 10,900 12,000 13,600 SHF — 0.76 — 0.73 — Input kW 0.650 0.750 0.960 0.980 Rated frequency Hz 35 43 51 54 Indoor unit MSZ-FD09NA MSZ-FD12NA V, Power supply phase, 208/230 , 1 , 60 Hz Input kW 0.018 0.024 0.024 0.030 Fan motor current A 0.19/0.17 0.25/0.23 0.25/0.23 0.32/0.29 Outdoor unit MUZ-FD09NA MUZ-FD12NA V, Power supply phase, 208/230 , 1 , 60 Hz Input kW 0.632 0.726 0.
ページ14に含まれる内容の要旨
7-5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY MUZ-FD09NA Correction of Cooling capacity Correction of Cooling total input Correction of Heating total input Correction of Heating capacity 1.5 1.5 2.0 3.0 1.5 1.0 1.0 2.0 1.0 0.5 0.5 1.0 0.5 0 50 100 150 (Hz) 0 50 100 150(Hz) 0 50 100 150(Hz) 0 50 100 150(Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor MUZ-FD12NA Cor
ページ15に含まれる内容の要旨
8 ACTUATOR CONTROL MUZ-FD09NA MUZ-FD12NA 8-1. OUTDOOR FAN MOTOR CONTROL The fan motor turns ON/OFF, interlocking with the compressor. [ON] The fan motor turns ON 5 seconds before the compressor starts up. [OFF] The fan motor turns OFF 15 seconds after the compressor has stopped running. 5 seconds 15 seconds ON Compressor OFF ON Outdoor fan motor OFF 8-2. R.V. COIL CONTROL . . . . . . . . . . . . . . . . . Heating ON . . . . . . . . . . . . . . . . . Cooling OFF . . . . . . . . . . . . . .
ページ16に含まれる内容の要旨
9 SERVICE FUNCTIONS MUZ-FD09VA MUZ-FD12VA 9-1. CHANGE IN DEFROST SETTING Changing defrost finish temperature To change the defrost finish temperature, cut/solder the JS wire of the outdoor inverter P.C. board. (Refer to 10-6-1.) Jumper Defrost fi nish temperature Soldered 41 °F (5 °C) (Initial setting) JS None 50 °F (10 °C) (Cut) 9-2. PRE-HEAT CONTROL SETTING PRE-HEAT CONTROL When moisture gets into the refrigerant cycle, it may interfere the start-up of the compressor at low outside temp
ページ17に含まれる内容の要旨
10-2. FAILURE MODE RECALL FUNCTION Outline of the function This air conditioner can memorize the abnormal condition which has occurred once. Even though LED indication listed on the troubleshooting check table (10-3.) disappears, the memorized failure details can be recalled. This mode is very useful when the unit needs to be repaired for the abnormality which doesn't recur. 1. Flow chart of failure mode recall function for the indoor/outdoor unit Operational procedure The cause of abnormali
ページ18に含まれる内容の要旨
2. Flow chart of the detailed outdoor unit failure mode recall function Operational procedure The outdoor unit might be abnormal. Confi rm if outdoor unit is abnormal according to the following procedures. Confi rm that the remote controller is in the failure mode recall function. With the remote controller headed towards the indoor unit, press TOO 1. Regardless of normal or abnormal condition, 2 short COOL or TOO WARM button to adjust the set temperature to 77 ˚F (25 ˚C). beeps are emitte
ページ19に含まれる内容の要旨
3. Outdoor unit failure mode table Indoor/outdoor Outdoor unit POWER lamp Abnormal point LED indication unit failure Condition Correspondence failure mode (Indoor unit) (Failure mode / protection) (Outdoor P.C. board) mode recall recall function function OFF None (Normal) —— — —— 2-time fl ash Outdoor power system Overcurrent protection stop is •Reconnect connectors. 2.5 seconds continuously performed 3 times within •Refer to 10-5. "How OFF 1 minute after the compressor gets to check
ページ20に含まれる内容の要旨
10-3. TROUBLESHOOTING CHECK TABLE Abnormal point/ No. Symptom LED indication Condition Correspondence Condition Outdoor unit 1-time fl ash every Outdoor power sys- Overcurrent protection stop is continuously performed 3 times •Reconnect connector of compres- does not oper- 2.5 seconds tem within 1 minute after the compressor gets started, or failure of sor. 1 ate. restart of compressor has repeated 24 times. •Refer to 10-5. "How to check in- verter/ compressor". •Check stop valve. Outdoor the