254892-YTG-C-0606
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are ava
ページ2に含まれる内容の要旨
254892-YTG-C-0606 PHYSICAL AND ELECTRICAL DATA - 1 PHASE MODEL H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06 Unit Supply Voltage 208-230V, 1 φ, 60Hz 1 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 9.4 11.8 15.1 18.3 18.3 30.3 32.7 2 15 20 25 30 30 50 50 Max. Overcurrent Device Amps 3 15 15 20 20 20 35 35 Min. Overcurrent Device Amps 4 B B Recip Recip Recip Recip Recip Compressor Type Scroll Scroll Rated Load 6.4 9.0 10.7
ページ3に含まれる内容の要旨
254892-YTG-C-0606 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06 Required TXV 1TVM2A1 1TVM2(A,B)1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory R-22 Charge, lbs-oz 4 - 9 6 - 3 5 - 13 6 - 0 8 - 13 8 - 6 10 - 2 1,2 3 Indoor Coil TXV KIT - Additional Charge, Oz FC/MC/PC/UC/UC18A2A 0 –––––– FC/MC/PC/UC18B2A 0 –––––– FC/MC/PC/UC24A2A 0 0 ––––– FC/MC/PC/UC24B2A 0 0 ––––– FC/MC/PC/
ページ4に含まれる内容の要旨
254892-YTG-C-0606 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued) Outdoor Unit H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06 Required TXV 1TVM2A1 1TVM2(A,B)1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory R-22 Charge, lbs-oz 4 - 9 6 - 3 5 - 13 6 - 0 8 - 13 8 - 6 10 - 2 1,2 3 Indoor Coil TXV KIT - Additional Charge, Oz HC18A3X 0 2B + 1 ––––– HC30A3X – 2A + 0 0 –––– HC36B3X – – 0 0 – – – HC42C3X –
ページ5に含まれる内容の要旨
254892-YTG-C-0606 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued) Outdoor Unit H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06 Required TXV 1TVM2A1 1TVM2(A,B)1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory R-22 Charge, lbs-oz 4 - 9 6 - 3 5 - 13 6 - 0 8 - 13 8 - 6 10 - 2 1,2 3 Indoor Coil TXV KIT - Additional Charge, Oz F2RP/F2FP040 –––0 ––– F2FP048 ––––0 –– F2FP060 ––––– 0* – F2FV060 –––––0 0 G4FA030S14T2A 0 –––––– G4FA030S
ページ6に含まれる内容の要旨
254892-YTG-C-0606 PHYSICAL AND ELECTRICAL DATA - 3 PHASE H1RD H1RD H1RD H1RD H1RD H1RD H1RD H1RD H1RD H1RD MODEL 030S25 036S25 042S25 048S25 060S25 030S46 036S46 042S46 048S46 060S46 Unit Supply Voltage 208-230V, 3 φ, 60Hz 460V, 3φ, 60Hz 1 187 to 252 432 to 504 Normal Voltage Range Minimum Circuit Ampacity 14.3 14.3 12.4 21.5 23.1 6.9 9.6 6.9 10.3 11.3 2 20 20 20 35 40 15 15 15 15 15 Max. Overcurrent Device Amps 3 15 15 15 25 25 15 15 15 15 15 Min. Overcurrent Dev
ページ7に含まれる内容の要旨
254892-YTG-C-0606 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit H1RD030S(25,46) H1RD036S(25,46) H1RD042S(25,46) H1RD048S(25,46) H1RD060S(25,46) Required TXV 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory R-22 Charge, lbs-oz 5 - 13 6 - 0 8 - 13 8 - 6 10 - 2 1 Additional Charge, Oz Indoor Coil FC/MC/PC/UC30A2A 0 –––– FC/MC/PC/UC30B2A 0 –––– FC/MC/PC/UC36A2A 0 0 – – – FC/MC/PC/UC36B2A 0 0 – – – FC/MC/PC/UC36C2A 0 0 – – – FC/MC/PC/UC42B2C – – 0 – – FC/MC/P
ページ8に含まれる内容の要旨
254892-YTG-C-0606 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase (Continued) Outdoor Unit H1RD030S(25,46) H1RD036S(25,46) H1RD042S(25,46) H1RD048S(25,46) H1RD060S(25,46) Required TXV 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory R-22 Charge, lbs-oz 5 - 13 6 - 0 8 - 13 8 - 6 10 - 2 1 Additional Charge, Oz Indoor Coil G4FA036S14T2A 0 –––– G4FA048S17T2A – 0 – – – G4FA048S17T2C – – 0 – – G4FA048S21T2A – 0 – – – G4FA048S21T2C – – 0 – – G4FA06
ページ9に含まれる内容の要旨
254892-YTG-C-0606 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT 1 ELECTRIC RATED NET MBH COIL MODEL MODEL MODEL W SEER EER 2 HEAT KW CFM TOTAL SENS. 1 & 3 PH 13 SEER AC WITH MA MA08B 2,5,8 17 FC/MC18B 600 17.5 11.7 13.00 11.00 H2RD018S06 MA08B 2,5,8 17 G*FD024H17 600 17.5 11.7 13.00 11.00 MA08B 2,5,8 17 FC/MC24B 800 23.0 16.6 13.00 11.00 H2RD024S06 MA08B 2,5,8 17 G*FD024H17 800 23.0 16.6 13.00 11.00 MA12B 5,8,10 17 FC/MC30B 1000 29.6 21.0 13.00 11.00 H2RD030S06 MA12B 5,
ページ10に含まれる内容の要旨
254892-YTG-C-0606 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT 1 ELECTRIC RATED NET MBH COIL MODEL MODEL MODEL W SEER EER 2 HEAT KW CFM TOTAL SENS. 1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED H2RD018S06 AV24 2,5,8,10,15 17 – 600 18.0 11.7 14.00 11.50 H2RD024S06 AV24 2,5,8,10,15 17 – 800 23.2 16.5 14.00 11.50 H2RD030S06 AV36 5,8,10,15,18 21 – 1000 30.0 21.2 14.00 11.50 AV36 5,8,10,15,18 21 – 1200 35.2 25.0 14.00 11.50 H2RD036S06
ページ11に含まれる内容の要旨
254892-YTG-C-0606 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL NET MBH UNIT MODEL CFM RANGE RATED 1 MODEL W SEER EER (MIN.-MAX.) CFM TOTAL SENS. 14,17 FC/MC/PC/UC18 600 17.5 11.7 13.00 11.00 14,17 FC/MC/PC/UC24 600 17.7 11.9 13.00 11.00 14 G*FA030S14 600 17.7 11.9 13.00 11.00 450 14,17 G*FD024H14,17 600 17.5 11.7 13.00 11.00 750 H2RD018S06 17 G*FD030H17 600 17.5 11.7 13.00 11.00 14 G*FD035H14 600 17.5 11.7 13.00 11.00 14 HC24 600 17.5 11.7 13
ページ12に含まれる内容の要旨
254892-YTG-C-0606 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL NET MBH UNIT MODEL CFM RANGE RATED 1 MODEL W SEER EER (MIN.-MAX.) CFM TOTAL SENS. 17,21 FC/MC/PC/UC42 1400 40.5 29.6 13.00 11.00 21,24 FC/MC/PC/UC48 1400 41.0 30.2 13.00 11.00 17 G*FA042S17 1400 40.5 29.6 13.00 11.00 21 G*FA048S21 1400 41.0 29.6 13.00 11.00 21 G*FD042H21 1400 40.5 29.6 13.00 11.00 1200 H2RD042S06 1600 17 G*FD046H17 1400 40.5
ページ13に含まれる内容の要旨
254892-YTG-C-0606 COOLING CAPACITY - With Variable Speed Furnaces COOLING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED FURNACE MODEL MODEL SEER EER CFM TOTAL SENS. 2 1 PH 13 SEER AC WITH VARIABLE SPEED FURNACES PV8*A12 FC/MC/PC18A 14 600 17.8 11.9 14.00 11.50 PV9*A12 FC/MC/PC18A 14 600 17.8 11.8 14.00 11.50 P(C,V)9*B12 FC/MC/PC18B 17 600 17.8 11.8 14.00 11.50 PV8*A12 FC/MC/PC24A 14 600 18.0 12.1 14.00 11.50 PV9*A12 FC/MC/PC24A 14 600 18.0 12.0 14.00 11.50 H2RD018S06 P(C,V)9*B12 FC/MC/P
ページ14に含まれる内容の要旨
254892-YTG-C-0606 COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED FURNACE MODEL MODEL SEER EER CFM TOTAL SENS. 2 1 PH 13 SEER AC WITH VARIABLE SPEED FURNACES PV8*A12 FC/MC/PC36A 14 1200 35.0 25.4 13.00 11.00 PV8*B16 FC/MC/PC36B 17 1200 35.2 25.6 13.75 11.00 PV8*C16 FC/MC/PC36C 21 1200 35.2 25.6 14.00 11.50 PV8*C20 FC/MC/PC36C 21 1200 35.2 25.6 14.00 11.50 PV9*A12 FC/MC/PC36A 14 1200 34.8 25.4 13
ページ15に含まれる内容の要旨
254892-YTG-C-0606 COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED FURNACE MODEL MODEL SEER EER CFM TOTAL SENS. 2 1 PH 13 SEER AC WITH VARIABLE SPEED FURNACES PV8*C16 FC/MC/PC48C 21 1500 46.5 34.2 13.00 11.00 PV8*C20 FC/MC/PC48C 21 1600 47.0 35.2 13.00 11.00 P(C,V)9*C16 FC/MC/PC48C 21 1600 47.0 35.2 13.00 11.00 P(C,V)9*C20 FC/MC/PC48C 21 1600 47.0 35.2 13.00 11.00 P(C,V)9*D20 FC/MC/PC48D 24 1600 47.0 35.2 13.25 11.00 PV8*C
ページ16に含まれる内容の要旨
254892-YTG-C-0606 1H/1C, auto/manual changeover, electronic programmable, ACCESSORIES deluxe 7-day, thermostat. Refer to Price Manual for specific model numbers. 1H/1C, auto/manual changeover, electronic programmable. HARD START KIT - Provides increased starting torque for * For the most current accessory information, refer to the areas with low voltage. price book or consult factory. COMPRESSOR BLANKET - Designed to further reduce the SOUND POWER RATINGS* normal com
ページ17に含まれる内容の要旨
254892-YTG-C-0606 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RD018S06 INDOOR COIL MODEL NO. FC/MC/PC/UC18 IDCFM 450 600 750 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 15.4 17.8 18.0 21.0 22.6 17.3 18.9 18.8 21.1 22.6 19.2 19.9 19.5 21.2 22.7 65 S.C. 15.1 13.5 11.8 12.2 9.6 17.0 15.8 13.2 13.3 10.0 18.9 18.2 14.5 14.4 10.5 KW 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.
ページ18に含まれる内容の要旨
254892-YTG-C-0606 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RD024S06 INDOOR COIL MODEL NO. FC/MC/PC/UC24 IDCFM 600 800 1000 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 21.8 23.8 23.8 25.7 28.3 24.1 25.1 25.1 26.8 29.8 21.8 26.5 26.5 28.0 31.3 75 S.C. 21.8 19.5 15.2 16.6 13.6 24.1 23.0 17.6 19.1 15.6 20.4 26.4 19.9 21.6 17.5 KW 1.60 1.62 1.62 1.65 1.6
ページ19に含まれる内容の要旨
254892-YTG-C-0606 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RD030S06 , H1RD030S(25,46) ** INDOOR COIL MODEL NO. FC/MC/PC/UC30 IDCFM 800 1000 1200 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 27.0 31.8 30.1 33.7 35.6 29.0 33.4 31.3 35.1 36.7 31.1 35.0 32.6 36.5 37.7 65 S.C. 26.9 24.7 20.6 21.2 16.0 29.0 27.7 22.9 23.4 17.7 31.1 30.7 25.2 25.6 19.5 KW 1.8 1.8 1.8 1.8 1.8 1.8 1.
ページ20に含まれる内容の要旨
254892-YTG-C-0606 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RD036S06 , H1RD036S(25,46) ** INDOOR COIL MODEL NO. FC/MC/PC/UC36 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 35.0 35.7 34.7 38.9 40.5 37.2 37.2 35.8 40.0 41.4 39.3 38.8 36.9 41.1 42.3 65 S.C. 32.1 30.0 25.0 25.8 19.7 33.8 32.8 27.5 28.1 21.3 35.6 35.7 29.9 30.4 22.9