HS3864ECH61HE(D)
ページ2に含まれる内容の要旨
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
ページ3に含まれる内容の要旨
Preface Thank you for purchasing this user system interface cable (HS3864ECH61H) for the Renesas’s original microcomputer H8/3864 series and H8/3887 series. The HS3864ECH61H is a user system interface cable that connects an H8/3864 series, H8/3887 series E6000 emulator (HS3880EPI60H; hereinafter referred to as the emulator) to the IC socket for a QFP-80A package (package code: FP-80A) for the H8/3864 series MCU on the user system. i
ページ4に含まれる内容の要旨
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ............................
ページ5に含まれる内容の要旨
Section 1 Configuration CAUTION Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3864ECH61H user system interface cable for the FP-80A package. 1
ページ6に含まれる内容の要旨
To emulator station Cable body Screws (M2 x 12 mm) with flat washers Screws (M2 x 8 mm) (for fastening cable head) with flat washers Socket cover Cable head IC socket User system Figure 1 HS3864ECH61H User System Interface Cable 2
ページ7に含まれる内容の要旨
Table 1 lists the HS3864ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3864ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-80A package 4 Socket cover 1 For installing an FP-80A-packaged MCU 5 Screws (M2 x 12 mm) 4 For fastening cable head 6 Screws (M2 x 8 mm) 4 For installing an FP-80A-packaged MCU (with four flat washers) 7 Documentation 1 User’s manual for
ページ8に含まれる内容の要旨
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect t
ページ9に含まれる内容の要旨
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow
ページ10に含まれる内容の要旨
2.2.4 Fastening Cable Head CAUTION 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC s
ページ11に含まれる内容の要旨
Fasten the user system interface cable head to the IC socket for an FP-80A package on the user system with the four screws (M2 x 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2 x 12 mm) with flat washers C
ページ12に含まれる内容の要旨
2.2.5 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body 8
ページ13に含まれる内容の要旨
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 20.50 (min.) 14.70 (max.) 0.65 19 = 12.35 0.1 + 0.1 0.35 0.65 0.05 - 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pad 9
ページ14に含まれる内容の要旨
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10
ページ15に含まれる内容の要旨
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head IC socket (IC149-080-017-B5 User system Unit: mm manufactured by Tolerance: –0.5 mm YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11
ページ16に含まれる内容の要旨
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may br
ページ17に含まれる内容の要旨
Screws (M2 x 8 mm) with flat washers Socket cover MCU Pin 1 IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 8 Installing MCU to User System 13
ページ18に含まれる内容の要旨
Section 4 Verifying Operation 1. When using the H8/3864 series, H8/3887 series E6000 emulator (HS3880EPI60H), turn on the emulator according to the procedures described in the H8/3864 series, H8/3887 series E6000 Emulator User's Manual (HS3880EPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator connected to this user s
ページ19に含まれる内容の要旨
Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. R1 1 M Ω Vcc 0.8 Vcc 0.8 Vcc HCU04 To E6000 emulator HCU04 0.3 Vcc 0.3 Vcc R2 270Ω 55 ns max. 55 ns max. 0 V OSC1 OSC2 Vcc: User System Vcc (1.8 to 5.5 V) System clock oscillator Subclock input specifications Figure 9 System Clock Oscillator and Subclock Input Specifications 15
ページ20に含まれる内容の要旨
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS3880EPI60H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the ca