ページ1に含まれる内容の要旨
WhisperKOOL
Split System
by Vinothèque
“THE COOLEST THING IN WINE STORAGE.” SS4000 & SS7000
Split Refrigeration System
Liquid Line
115 VAC
115 VAC
Suction
Drain
Evaporator Condensing Unit
(Indoor) (Indoor/Outdoor)
!
Thank you for choosing WhisperKOOL Split
The WhisperKOOL
Cooling System for your wine preservation
Split Cooling System
needs. This unit has been specifically designed
requires professional
and engineered to create the ideal balance
installation by
of temperature and humid
ページ2に含まれる内容の要旨
Copyright ©1998-2008 Vinothèque Wine Cellars All rights reserved. This manual, the product design, and the design concepts are copyrighted by Vinothèque Wine Cellars, with all rights reserved. Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the United States of America. Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any printed or electronic medium or
ページ3に含まれる内容の要旨
TABLE OF CONTENTS WhisperKOOL Split Cooling System Features & Benefits....................................................................................... 4 System & Features......................................................................................... 5 PDT Thermostat Operating Instructions...................................................... 6 Package Contents........................................................................................... 7 Wine Cellar /
ページ4に含まれる内容の要旨
FEATURES & BENEFITS Designed specifically for wine storage, the WhisperKOOL system is a specialized refrigeration unit designed for one purpose only: to maintain the optimal temperature and humidity levels conducive to the proper aging of fine wines. Humidity Control As the temperature begins to drop within the cellar, the relative humidity will rise. The WhisperKOOL units do not create humidity. If you live in a dry area of the country, you may need to add humidity in the wine cella
ページ5に含まれる内容の要旨
System & Features The system includes both the evaporator and condensing units packaged in two (2) separate containers. An exterior housing is required for outdoor installations and will arrive packed separately. Evaporator Condensing Unit (Shown With Housing) Thermostat The split system evaporator has been designed to incorporate the Vinothèque PDT ™ series thermostat. Years of research and testing have gone into the design of the PDT thermostat resulting in advanced microprocessor con
ページ6に含まれる内容の要旨
PDT OPERATING INSTRUCTIONS The unit is set at 55°F at the factory. To raise or lower the temperature set point, press the set button while at the same time pressing either the arrow up or arrow down button. 1 WINE Temperature Indicator 2 LED Screen 3 Wine Temperature Reading WINE PDT ON Precision digital Technology Thermostat 55F SET Temperature SET 4 7 8 Temperature SET Indicator UP Arrow Button DOWN Arrow Button 5 6 SET Temperature Button Unit ON Indicator 1. Wine Temperature Indicator: A
ページ7に含まれる内容の要旨
PACKAGE CONTENTS SS4000 Box 1 Evaporator Unit (part #: 03-4000SS-0120) Sight Glass Filter Drier Box 2 Condensing Unit (part #: 1-122100) Accessory Kit (par #: 09-950-9997SS) Box 3 Optional Exterior Housing (part #: 03-4000SS-0120) Mounting Hardware Optional Electrical Cover SS7000 Box 1 Evaporator Unit (part #: 03-7000SS-0120) Sight Glass Filter Drier Box 2 Condensing Unit (part #: 1-122101) Accessory Kit (part #: 09-950-9997SS) Box 3 Optional Exterior Housing (part #: 03-7000
ページ8に含まれる内容の要旨
WINE CELLAR / SPACE PREPARATION Preparing the Wine Cellar The proper design and preparation of the wine cellar is essential in order to maintain the ideal temperature and humidity levels. We have created a typical presentation on “How to Build a Wine Cellar” which is available for viewing on our web site at www.whisperkool.com. Failure to prepare the cellar accordingly will result in the cellar not maintaining proper temperature and humidity. Technical Specifications Sizing Guide & Speci
ページ9に含まれる内容の要旨
SPLIT SYSTEM INSTALLATION GUIDELINES General Installation Guidelines and Instructions Vinothèque requires that a certified HVAC technician install and pipe the Split System unit modules. Please take a moment to review State and City building codes to insure the safe and proper installation of the unit. Installing Condensing Unit The condensing unit can be mounted inside a utility area of the home or outside utilizing the required outdoor condensing unit housing. The system will operate on a
ページ10に含まれる内容の要旨
CONDENSING UNIT SKID PREPARATION Note: The condensing unit is shipped with a pr otective foam pad/ block to pr event damaging tubing against the condenser coil fins. Please ensure that this pad is removed prior to operation. Condensing Unit -10-
ページ11に含まれる内容の要旨
Head Pressure Control, Low Ambient Control Switch: The switch is used to cycle the condenser fan at low ambient temperature condition. Set the switch to 170 psig for cut-in and 70 psig for the differential. Further adjustment may be needed. Verify the settings via refrigeration manifold gauge and perform the final adjustments to the readings on the gauge manifold. Low Ambient Control* High Pressure Cutout Low Pressure Cutout Condensing Unit * Low ambient control is in the control box -11-
ページ12に含まれる内容の要旨
MOUNTING THE EVAPORATOR UNIT 1. Disassemble evaporator unit. In order to mount the housing to the wall, the internal components will need to be removed and reinstalled after mounting the housing. Remove front cover and thermostat by unscrewing four captive screws located on each corner of the cover and five at bottom of front cover. Note: Thermostat is not plugged into electrical line. 2. Remove interior assembly. The interior assembly is one piece. The assembly should slide out on mount
ページ13に含まれる内容の要旨
3. Identify and remove appropriate knockouts. There are knockouts located on the rear panel, right side panel and on top. Remove knockouts for the two refrigeration lines and install the two grommets supplied. Remove knockout for electrical line. Keep the refrigerant pipes capped to prevent any foreign material from entering, until ready to braze. 4. Mounting housing to wall. The unit has six mounting holes on 16 inch wide centers. Utilize all mounting screws to secure the housing to the
ページ14に含まれる内容の要旨
5. Installing refrigeration lines into evaporator housing. With knockouts removed, install grommets supplied. Install housing, mark location and center line of holes to be drilled in wall. Slide interior into place, measure the distance from the suction and liquid line connection locations to the housing knockout opening. Add that dimension to the length of pipe necessary to penetrate the wall for a rear entry plus enough for an elbow connection if the pipe is to run up or down the
ページ15に含まれる内容の要旨
6. Run the electrical line into evaporator on bottom of left side over insulation. Wires should be at least 36” long going into the cabinet. 7. Re-install interior assembly. Slide interior assembly back into housing gently. Re-attach using the two screws. Flow a small amount of dry nitrogen through the tubing during brazing. This is to displace oxygen and prevent the formation of copper oxide. The solenoid should be energized for a free flow without building up pressure in the tubing. -
ページ16に含まれる内容の要旨
8. Attaching refrigeration lines. Line up the piping connections. Energize the liquid line solenoid valve, connect Dry Nitrogen, and adjust to a slight flow through the tubing, being sure no pressure develops in the piping. Connect flare fittings if a flare fitting model, tighten securely, braze other fittings, leak check, evacuate to 200 microns, charge with R-134 refrigerant, start and check out. Using wire ties, secure tubing as low as possible in the evaporator so tubing is not visible
ページ17に含まれる内容の要旨
9. Electrical wires will need to be approximately 36 inches long. Attach lines according to schematic shown. Legend L8 T8 L2 T2 Power Source Thermostat L1 - White (neutral) T1 L1 L2 - Black (hot) 115V 60Hz L3 - Black Silver Stripe T3 J1 L8 - Green (ground) T1 - White T2 - Black T3 - Black / White T8 - Green F1 - White J1 F2 - Black F8 - Green F8 Fan Solenoid Valve S1 - White F1 S1 J1 S2 - Black F2 S2 J1 - White Jumper 10. Install drain line fitting and drain line. Excess moisture in the ai
ページ18に含まれる内容の要旨
11. Install thermostat. Thermostat mounts on the bottom front of the unit. Plug electrical outlet to thermostat and mount from underneath with screws supplied. 12. Install front cover. 13. Energize unit. Note: Thermostat has a 5 minute time delay. -18-
ページ19に含まれる内容の要旨
Refrigeration Lines 1 A /4 inch O/D copper “liquid line” and a ½ inch O/D copper “suction line” connect the two units. The refrigerant drier and sight glass shall be installed in that order in direction of refrigerant flow in the liquid line between the condensing unit and evaporator. Enclose the suction line in a cellular insulation ½” wall thickness Armaflex (brand name) or equal to r educe heat transfer . Wiring System The compressor is controlled by a “pump down cycle,” therefore, no
ページ20に含まれる内容の要旨
Split Unit Wiring Diagram -20-