ページ1に含まれる内容の要旨
Lucent Technologies
Bell Labs Innovations
CIB 3140
(533B) Memory Module (61227A)
(106433691)
CIB 3140
Comcode 106433691
Issue 2
January 1997
ページ2に含まれる内容の要旨
Memory Module ® When installed in the MERLIN Plus system control unit, this memory module (Figure 1) upgrades your system to the MERLIN Plus Communi- cations System Release 2. MEMORY MODULE Figure 1 MERLIN Plus Communications System Release 2 Memory Module The new system features available with this memory module are listed below. For further informaiton about each feature, refer to Section 5, "Reference," of your new MERLIN Plus Communicaiton System Release 2 System Manual. ● Automatic System
ページ3に含まれる内容の要旨
NOTE: This memory module also houses a battery that preserves all programming for at least four days in case of a power failure. In addition, a 450F adapter is included to provide a connection between the control unit and the Data Collector, and to allow the Data Collector and the Busy Buster feature to share the same jack on the voice terminal module. Refer to the Addendum to CIB 3051 for installation instructions. INSERTING AND REMOVING THE MEMORY MODULE Follow the procedures listed below for
ページ4に含まれる内容の要旨
Loosened screw Figure 2 Removing the Front and Top Covers From the control Unit 4 To Insert the new memory module, first grasp its plastic handle on the front and align the four pin guides at each corner of the module with the rectangular opening at the top of the control unit (Figure 3). Push the module in until the gold pins insert fully into their receptacle. 5 The module will snap into place. 6 Replace the control unit top cover. If you are using the Busy Buster feature or any of the Automat
ページ5に含まれる内容の要旨
Memory module Figure 3 Inserting and Removing the Memory Module 8 Plug the power cord back into the outlet and set the power switch on the control unit to On. 9 Replace the front cover on the control unit. Remember, you will have to readminister and reprogram your sets as described in Section 3, "Administering the System," of your new System Manual. 4
ページ6に含まれる内容の要旨
Customer Administerable Timer The Customer Administerable Timer is used in conjunction with the Call Forwarding and Remote Line Access features. The timer disconnects calls made via Call Forwarding and/or Remote Line Access after these calls reach a system-wide call duration limit. The Customer Administerable Timer can be set to a value of from 1 to 999 minutes. To administer the Customer Administerable Timer: 1. Enter administration mode by sliding the T/P switch to P and touching Administer. 2
ページ7に含まれる内容の要旨
Lucent Technologies Bell Labs Innovations Copyright © 1996, Lucent Technologies All Rights Reserved Printed in U.S.A.