AIR CONDITIONER
Use & Care Guide
For questions about features, operation/performance, parts,
accessories or service, call: 1-800-253-1301 in the U.S.A.
ACONDICIONADOR
DE AIRE
Manual de uso y cuidado
Si tiene preguntas respecto a las características, funcionamiento,
rendimiento, piezas, accesorios o servicio técnico,
llame al: 1-800-253-1301 en los EE. UU.
Table of Contents/Índice ..................................... 2
66121560A
ページ2に含まれる内容の要旨
TABLE OF CONTENTS AIR CONDITIONER SAFETY .........................................................2 Starting Your Air Conditioner—Rotary Control— Cool Only Models.......................................................................14 INSTALLATION REQUIREMENTS ................................................3 Starting Your Air Conditioner—Rotary Control— Tools and Parts ............................................................................3 Heat/Cool Models ...............................
ページ3に含まれる内容の要旨
IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions: Plug into a grounded 3 prong outlet. Do not use an extension cord. Do not remove ground prong. Unplug air conditioner before servicing. Do not use an adapter. Use two or more people to move and install air conditioner. SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS NOTES: On some models, the front panel is not attached to the air
ページ4に含まれる内容の要旨
Window Installation Through-the-Wall Installation Window opening measurements: The wall opening measurements should be: 30" to 40" (76.2 cm to 101.6 cm) opening width. Width: 26¹⁄₂" (66.1 cm) plus twice thickness of wood used to build frame. 20" (50.8 cm) minimum opening height. Height: 19³⁄₄" (50.2 cm) plus twice thickness of wood used to build frame. Depth: Dimension for depth depends on the wall thickness and the type of molding. C A A B B D C A. 30" (76.2 cm) minimum A. 19³⁄₄" (
ページ5に含まれる内容の要旨
RESET RESET TEST TEST It is the customer's responsibility: To contact a qualified electrical installer. WARNING To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Copies of the standards listed may be obtained from: National Fire Protection Association One Batterymarch Park Electrical Shock Hazard Quincy, MA 02269 Plug into a grounded 3 prong outlet. Power Supply Cord Do
ページ6に含まれる内容の要旨
3. Remove the front panel from the air conditioner and set 6. Pull on the handles to slide the air conditioner out of the aside. cabinet. Place the air conditioner on cardboard. 4. Remove the shipping lock bracket and screw from the air conditioner and set aside. A A B A. Handles A. Shipping lock bracket screw B. Shipping lock bracket NOTE: Do not lift, push, pull or remove any expanded polystyrene (foam) from inside the air conditioner. It is not 5. Remove the ground screw and ground wire f
ページ7に含まれる内容の要旨
4. While the right-hand curtain is still extended, insert #10 x ¹⁄₄" Attach Side Curtains pan-head Phillips screws into the top and bottom slots of curtain. Screw the curtain to the top and bottom holes in the 1. Locate the bag of screws provided. air conditioner cabinet. NOTE: Some curtains may have 2 slots at each end. You will 2. Insert the top and then the bottom of the right-hand curtain housing in the top and bottom curtain guides on the air be able to see a mounting hole through the
ページ8に含まれる内容の要旨
3. Repeat for the left side. Adjust the cabinet until the distance Top View on each side is the same. A A B B C C A. Window channel B. Left-hand curtain C. #10 x ³⁄₄" round-head screw A. Window sash 2. Insert one of the #10 x ³⁄₄" round-head screws through the hole in the top of the curtain. B. Empty cabinet C. Window channel 3. Insert one of the #10 x ³⁄₄" round-head screws through the slotted hole in the bottom of the curtain. 4. Use a ³⁄₃₂" drill bit to drill 4 starter holes ³⁄₈" deep
ページ9に含まれる内容の要旨
2. Using #10 x ¹⁄₂" pan-head Phillips screws, attach the bracket to the cabinet. Repeat for the other bracket. Complete Window Installation 3. Turn the adjustment bolt for each bracket until the bolt 1. Insert the foam window sash seal behind the top of the lower touches the wall. window sash and against the glass of the upper window. 4. Turn the locking nut on the adjustment bolt to lock in position. 2. Place one window-lock bracket on top of the lower window and against the upper window sa
ページ10に含まれる内容の要旨
NOTES: 2. Use a level to check that the cabinet is level side to side. Dimension for depth depends on the wall thickness and the type of molding. Do not block louvers in the air conditioner cabinet. Use 1" (2.5 cm) or thicker lumber for the wood frame. A A A. Level B 3. Check that the air conditioner cabinet is tilted to the outside so that water will run to the outside. C Complete Through-the-Wall Installation A. Outside width 1. Reuse the insulation to seal opening between the cabine
ページ11に含まれる内容の要旨
5. Using 2 - #10 x ³⁄₈" painted round-head screws, attach the bottom front of the panel. WARNING Electrical Shock Hazard Connect green ground wire to ground screw. Failure to do so can result in death or electrical shock. 3. Connect the green ground wire to the ground screw. NOTE: For through-the-wall installations, if needed, install the Position the ground wire pointing straight up. Put the excess molding around the room side of cabinet. ground wire between the coil and the air conditioner
ページ12に含まれる内容の要旨
P O Starting Your Air Conditioner—Digital Control Fan Speed NOTE: The Fan Speed button will operate only when the Cool or Power Saver mode has been selected. 1. Press and hold FAN SPEED until you see the indicator light for the desired setting. 2. Choose Turbo, High, Low or Auto. NOTES: When the air conditioner is off, the display shows the current Filter Monitor room temperature. If the room temperature is below 55ºF (13ºC), the display will 1. When filter indicator light is lit or
ページ13に含まれる内容の要旨
AUTO SWING To set the Timer to turn on the air conditioner, changing Timer Delay previous settings: 1. Turn on the air conditioner. To set the Timer to turn off the air conditioner (the air 2. Adjust the mode to Cool, Fan Only, or Power Saver. conditioner must be On): 3. Adjust the fan speed to Turbo, High, Low or Auto. 1. Press TIMER. Timer indicator light will flash. Display will show 4. Adjust temperature between 64°F and 86°F (18ºC and 30ºC). remaining hours before the air conditioner wil
ページ14に含まれる内容の要旨
3. Press the plus or minus button to change delay time from 1 to To Set the Timer Delay 24 hours. 4. Press TIMER again or wait 10 seconds. Timer indicator light To set Timer to turn off the air conditioner (air conditioner on the air conditioner control panel will remain on. must be on): 1. Press TIMER. Timer indicator light on the air conditioner To set Timer to turn on the air conditioner, changing the control panel will flash. previous settings: 1. Turn on the air conditioner. TIMER 2. A
ページ15に含まれる内容の要旨
Starting Your Air Conditioner—Rotary Control—Heat/Cool Models Low Cool—for sleeping comfort Fan Only—to move air continuously without cooling or heating Wait three minutes before restarting NOTE: Fan runs on Turbo speed only. OFF LOW Power Saver—fan runs only when cooling or heating is FAN 7 7 HEAT ONLY 6 6 needed. 5 5 Since the fan does not circulate the room air continuously, 4 4 TURBO POWER HEAT SAVER less energy is used, but the room air is not circulated as 3 3 often. Use Power
ページ16に含まれる内容の要旨
SWING Changing Air Direction Normal Sounds Use the Air Swing button on the air conditioner control panel or When your air conditioner is operating normally, you may hear the Swing button on the remote control to direct air left or right. sounds such as: Droplets of water hitting the condenser, causing a pinging or clicking sound. The water droplets help cool the condenser. Air movement from the fan. AIR SWING Clicks from the thermostat cycle. Use the tab to direct air up, down or straigh
ページ17に含まれる内容の要旨
TROUBLESHOOTING Before calling for service, try the suggestions below to see whether you can solve your problem without outside help. Air conditioner will not operate Air conditioner power supply cord trips (Reset button pops out) Disturbances in your electrical current can trip (Reset WARNING button will pop out) the power supply cord. Press and release RESET (listen for click; Reset button will latch and remain in) to resume operation. Electrical overloading, overheating, cord pinching
ページ18に含まれる内容の要旨
There is excessive heat or moisture (open container The Temperature is not set at a cool enough setting. cooking, showers, etc.) in the room. Use a fan to exhaust Adjust the Temperature control to a cooler setting by turning heat or moisture from the room. Try not to use heat- the knob clockwise. Turn the Fan Speed control to Turbo producing appliances during the hottest part of the day. Cool. The louvers are blocked. Install the air conditioner in a The air conditioner in the heating
ページ19に含まれる内容の要旨
Accessories You can order the following accessories for your air conditioner from your local authorized dealer or by calling 1-800-253-1301 Heavy-duty cover from anywhere in the U.S.A. You will hear a recording. Follow the instructions to place an order. If you decide to leave your air conditioner installed during the winter, a heavy-duty cover will help protect your air conditioner and reduce drafts. The outdoor cover protects against cold drafts Replacement Air Filters through the unit's
ページ20に含まれる内容の要旨
REQUISITOS DE INSTALACIÓN Herramientas y piezas Requisitos de ubicación Reúna las herramientas y piezas necesarias antes de comenzar IMPORTANTE: Observe todos los códigos y reglamentos la instalación. Lea y siga las instrucciones provistas con aplicables. cualquiera de las herramientas enlistadas aquí. Verifique el lugar donde se instalará el acondicionador de aire. La instalación correcta es su responsabilidad. Asegúrese de que Herramientas necesarias usted tenga todo lo necesario para una i