ページ1に含まれる内容の要旨
R
Notes on Spare Drives using the Easy RAID Setting (EZ)
When EZ is function is ENABLED, the auto-rebuilding to spare drive is automatic.
T E C H N O L O G I E S
The degraded RAID group will start rebuilding automatically by using the existing
spare drive.
* Spare drive can be either plugged before RAID building or a new drive can be plug
as the spare drive when RAID rebuild is required.
A. Which port acts as a spare drive?
The last drive will automatically become the spare drive.
For a 3-dr
ページ2に含まれる内容の要旨
RAID Setting Notes: Back View When 2 drives are RAID 1& RAID 10 Mode connected to the HPM-XA, Power Jack and DIP switch is set to this USB 3.0/2.0 Host Port setting, the 2 drives will be SW1 1 2 3 4 5 eSATA Port configured as a 2-drive RAID1 array. BZS EZ M2 M1 M0 Dip Switch When 4 drives are connected to the HPM-XA, the 4 drives will be configured as a 4-drive RAID10 array. Clone’s action is similar to Clone Mode RAID1. However, all of the hard drives will be
ページ3に含まれる内容の要旨
Default factory DIP Switch setting: Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program: SW1 – RAID Setting DIP Switch 1. For Windows users, install the JMicron HW RAID Manager located on the BZS – Error buzzer function SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a manager can be use to create and monitor the status of the RAID volume. spa
ページ4に含まれる内容の要旨
SATA Ports e. On the DIP switch, change (M0 to M2) setting to the desired RAID mode using the diagram below. All settings on the diagram shows • Error buzzer function is ENABLED • EZ function is DISABLED. RAID 0 Mode Clone Mode Error Buzzer and Alarm Drive SW1 SW1 Activity 1 2 3 4 5 1 2 3 4 5 LEDs Floppy BZS EZ M2 M1 M0 BZS EZ M2 M1 M0 Power Connector RAID 1& RAID 10 Mode Large Mode USB 3.0/2.0 Host Port Dip Switch eSATA Hos