ページ1に含まれる内容の要旨
T E C H N O L O G I E S
User Guide
RAID Tower III
(RT3S5HEU3)
www.addonics.com
v8.1.11
Technical Support
If you need any assistance to get your unit functioning properly, please have your
product information ready and contact Addonics Technical Support at:
Hours: 8:30 am - 6:00 pm PST
Phone: 408-453-6212
Email: http://www.addonics.com/support/query/
ページ2に含まれる内容の要旨
Back View Power Jack USB 3.0/2.0 Host Port eSATA Port Dip Switch Installing drives into the RAID Tower III 1. Be sure the lock on each drive door is in an unlock position. If not, use the key that comes Door Lock with the Disk Array to unlock the drive door. Pull on the door lever to swing open the drive door all the way. 2. Slide a 3.5” SATA hard drive into the drive slot Individual with the drive connector side facing in. Be sure to Drive Bay orient the hard drive correctly as shown
ページ3に含まれる内容の要旨
SATA Ports Error Buzzer and Alarm Drive Activity LEDs Floppy Power Connector USB 3.0/2.0 Host Port Dip Switch eSATA Host Port (Port 5) RAID Setting Button Dip Switch Settings Raid Mode 1 2 3 4 5 Individual Drive OFF OFF OFF OFF OFF (Factory Default) 0 OFF OFF ON ON ON 1 and 10 OFF OFF ON ON OFF 3 OFF OFF ON OFF OFF 5 OFF OFF OFF ON OFF Clone OFF OFF OFF ON ON Large OFF OFF ON OFF ON Enable Auto- Port Multiplier Mode ERR Buzzer Rebuilding Function to
ページ4に含まれる内容の要旨
Default factory DIP Switch setting: SW1 – RAID Setting DIP Switch BZS – Error buzzer function EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start. M2 – RAID mode 2 M1 – RAID mode 1 M0 – RAID mode 0 SW1 1 2 3 4 5 BZS EZ M2 M1 M0 1. Error buzzer function is ENABLED (BZS) wh
ページ5に含まれる内容の要旨
Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program: 1. For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume. It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager. 2. Modify the RAID mode on the 5-port HPM-XA using DIP switch Recommende
ページ6に含まれる内容の要旨
Setting or Modifying the RAID Mode Using the JMicron e. On the DIP switch, change (M0 to M2) setting to the desired RAID mode using the diagram below. HW RAID Manager Utility Program: All settings on the diagram shows 1. For Windows users, install the JMicron HW RAID Manager located on the • Error buzzer function is ENABLED SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This • EZ function is DISABLED. manager can be use to create and monitor the sta
ページ7に含まれる内容の要旨
RAID Setting Notes: When 2 drives are RAID 1& RAID 10 Mode connected to the HPM-XA, and DIP switch is set to this setting, the 2 drives will be SW1 1 2 3 4 5 configured as a 2-drive RAID1 array. BZS EZ M2 M1 M0 When 4 drives are connected to the HPM-XA, the 4 drives will be configured as a 4-drive RAID10 array. Clone’s action is similar to Clone Mode RAID1. However, all of the hard drives will be mirrored. Clone mode is useful SW1 especially when users like
ページ8に含まれる内容の要旨
Notes on Spare Drives using the Easy RAID Setting (EZ) When EZ is function is ENABLED, the auto-rebuilding to spare drive is automatic. The degraded RAID group will start rebuilding automatically by using the existing spare drive. * Spare drive can be either plugged before RAID building or a new drive can be plug as the spare drive when RAID rebuild is required. A. Which port acts as a spare drive? The last drive will automatically become the spare drive. For a 3-drive RAID5 with spare: Dri