ページ4に含まれる内容の要旨
Page 4 Version 1.0 March 1, 2000
ページ5に含まれる内容の要旨
Section 1: Parameterization of Base Unit SIMOVERT MASTERDRIVES 6SE70 VC Vector Control 1.1 Power Section Defintion 1.2 Factory Reset 1.3 Basic Start-up 1.3.1 Volts/Hz without encoder feedback 1.3.2 Volts/Hz with encoder feedback 1.3.3 Vector Control without encoder feedback 1.3.4 Vector Control with encoder feedback 1.4 Drive Control Word 1.5 Communication Board Configuration Note: Refer to Operating Instruction Manual for power and control connections. Version 1.0 March 1, 2000 Page 5
ページ6に含まれる内容の要旨
Page 6 Version 1.0 March 1, 2000
ページ7に含まれる内容の要旨
1.1 Power Section Definition Note: Power Section is pre-defined at the factory. Power Section Definition is required if a new board CUVC board is put into the drive or boards are switched between units with different ratings. Drive should be defaulted and re-parameterized after Power Section Definition. Select “Power Section Definition” P060 = 8 Menu Input Code for unit (PWE) (Refer to Compendium section P070 = ? 6.3 or use the bookmark “PWE Listing” or check the following table) P060 = 1 Ret
ページ8に含まれる内容の要旨
Unit List P070: Parameter Value (PWE) P072: Rated Output Current in Amps In[A] Frequency Converter AC-AC type *1 3 AC 200V to 230V PWE Order Number In[A] 14 6SE7021-1CA60 10.6 21 6SE7021-3CA60 13.3 27 6SE7021-8CB60 17.7 32 6SE7022-3CB60 22.9 39 6SE7023-2CB60 32.2 48 6SE7024-4CC60 44.2 54 6SE7025-4CD60 54.0 64 6SE7027-0CD60 69.0 70 6SE7028-1CD60 81.0 13 6SE7031-0CE60 100.0 29 6SE7031-3CE60 131.0 41 6SE7031-6CE60 162.0 87 6SE7032-0CE60 202.0 Frequency Inverter DC-AC type *1 DC 270V to 310V P
ページ9に含まれる内容の要旨
Frequency Converter AC-AC type 3 AC PWE PWE *1 Order Number In[A] 380V to 460V Air Cooled Water Cooled 3 6SE7016-1EA61 6.1 9 6SE7018-0EA61 8.0 11 6SE7021-0EA61 10.2 18 6SE7021-3EB61 13.2 25 6SE7021-8EB61 17.5 35 6SE7022-6EC61 25.5 42 6SE7023-4EC61 34.0 46 6SE7023-8ED61 37.5 52 6SE7024-7ED61 47.0 56 6SE7026-0ED61 59.0 66 6SE7027-2ED61 72.0 74 6SE7031-0EE60 92.0 82 6SE7031-2EF60 124.0 90 6SE7031-5EF60 146.0 98 6SE7031-8EF60 186.0 102 6SE7032-1EG60 210.0 108 6SE7032-6EG60 260.0 112 6SE7033-2EG60 31
ページ10に含まれる内容の要旨
Frequency Inverter DC-AC type DC PWE PWE *1 Order Number In[A] 510V to 650V Air Cooled Water Cooled 4 6SE7016-1TA61 6.1 10 6SE7018-0TA61 8.0 12 6SE7021-0TA61 10.2 19 6SE7021-3TB61 13.2 26 6SE7021-8TB61 17.5 36 6SE7022-6TC61 25.5 43 6SE7023-4TC61 34.0 47 6SE7023-8TD61 37.5 53 6SE7024-7TD61 47.0 57 6SE7026-0TD61 59.0 67 6SE7027-2TD61 72.0 75 6SE7031-0TE60 92.0 83 6SE7031-2TF60 124.0 91 6SE7031-5TF60 146.0 99 6SE7031-8TF60 186.0 103 6SE7032-1TG60 210.0 109 6SE7032-6TG60 260.0 113 6SE7033-2TG60 315.
ページ11に含まれる内容の要旨
Frequency Converter AC-AC type 3 AC PWE PWE *1 Order Number In[A] 500V to 575V Air Cooled Water Cooled 1 6SE7014-5FB61 4.5 5 6SE7016-2FB61 6.2 7 6SE7017-8FB61 7.8 16 6SE7021-1FB61 11.0 23 6SE7021-5FB61 15.1 30 6SE7022-2FC61 22.0 37 6SE7023-0FD61 29.0 44 6SE7023-4FD61 34.0 50 6SE7024-7FD61 46.5 60 6SE7026-1FE60 61.0 62 6SE7026-6FE60 66.0 68 6SE7028-0FF60 79.0 78 6SE7031-1FF60 108.0 84 6SE7031-3FG60 128.0 94 6SE7031-6FG60 156.0 100 6SE7032-0FG60 192.0 104 6SE7032-3FG60 225.0 136 222 6SE7033-0FK60
ページ12に含まれる内容の要旨
Frequency Inverter DC-AC type DC PWE PWE *1 Order Number In[A] 675V to 810V Air Cooled Water Cooled 2 6SE7014-5UB61 4.5 6 6SE7016-2UB61 6.2 8 6SE7017-8UB61 7.8 17 6SE7021-1UB61 11.0 24 6SE7021-5UB61 15.1 31 6SE7022-2UC61 22.0 38 6SE7023-0UD61 29.0 45 6SE7023-4UD61 34.0 51 6SE7024-7UD61 46.5 61 6SE7026-1UE60 61.0 63 6SE7026-6UE60 66.0 69 6SE7028-0UF60 79.0 79 6SE7031-1UF60 108.0 85 6SE7031-3UG60 128.0 95 6SE7031-6UG60 156.0 101 6SE7032-0UG60 192.0 105 6SE7032-3UG60 225.0 110 200 6SE7033-0UJ60 297
ページ13に含まれる内容の要旨
Frequency Inverter DC-AC type DC PWE PWE *1 Order Number In[A] 675V to 810V Air Cooled Water Cooled 161 6SE7043-3UR60 3270.0 165 6SE7044-1UR60 4090.0 169 6SE7044-8UR60 4900.0 173 6SE7045-7UR60 5720.0 177 6SE7046-5UR60 6540.0 179 245 6SE7036-5UR60 4940.0 182 248 6SE7038-6US60 6540.0 186 251 6SE7041-1US60 6160.0 188 253 6SE7041-2US60 5840.0 190 240 6SE7042-1UN60 2050.0 192 242 6SE7042-3UN60 2340.0 Frequency Converter AC-AC type 3 AC PWE PWE *1 Order Number In[A] 660V to 690V Air Cooled Water Coole
ページ14に含まれる内容の要旨
DC PWE PWE *1 Order Number In[A] 890V to 930V Air Cooled Water Cooled 77 6SE7031-0WG60 97.0 81 6SE7031-2WF60 118.0 89 6SE7031-5WF60 145.0 97 6SE7031-7WG60 171.0 107 6SE7032-1WG60 208.0 111 201 6SE7033-0WJ60 297.0 115 203 6SE7033-5WJ60 354.0 119 205 6SE7034-5WJ60 452.0 122 208 6SE7035-7WK60 570.0 125 211 6SE7036-5WK60 650.0 129 215 6SE7038-6WK60 860.0 131 217 6SE7041-0WM60 990.0 133 219 6SE7041-1WM60 1080.0 139 225 6SE7041-2WM60 1230.0 145 231 6SE7041-4WM60 1400.0 6SE70414WQ60 149 235 6SE7041-6WM
ページ15に含まれる内容の要旨
1.2 Factory Reset 6: Parameter Changes permitted P053 = 6 via PMU and Serial Interface (OP1 and PC) 2: Menu Select = Fixed Settings P060 = 2 Select Factory Setting P366 = 0 0: Standard Start Parameter Reset P970 = 0 0: Parameter Reset 1: No Parameter Change Version 1.0 March 1, 2000 Page 15
ページ16に含まれる内容の要旨
Page 16 Version 1.0 March 1, 2000
ページ17に含まれる内容の要旨
1.3 Basic Start-up without Motor Connected to Load 1.3.1 Volts/Hz without Encoder P060=5 P060 = 5 Select “Drive Settings” P071 = Input Line Voltage P071 = ? AC-AC Converter=460Volt DC-AC Inverter = 620Volt P095 = Select Motor Type 2: Asynchronous 1PH7 Motor 10: IEC Induction Motor P095 = ? 11: NEMA Induction Motor P095 = 2 10 or 11 P097 = Motor Code number for 1PH7 motor (See Appendix) P097 = ? Motor Nameplate Information P101= Motor Voltage (V) P101 = 460 P102 = Motor Rated C
ページ18に含まれる内容の要旨
P106 = NEMA Motor Nameplated efficiency (if unknown set =0.8) P106 = ? P107 = Rated Motor Frequency P107 = 60 P108 = Nameplated Rotor RPM P108 = xxxx P115 = 1 “Automatic Parameterization” P115 = 1 P340 = Carrier Frequency Low # = Cooler Motor and Drive High # = Lower Motor Noise P340 = 3 P383 = Motor Thermal Time Constant. If constant unknown use general guidelines; P383 = xxxx 2 Pole Motor = 480 seconds 4 Pole Motor = 600 seconds 6 Pole Motor = 720 seconds P452 = Maximum Forwa
ページ19に含まれる内容の要旨
P453 = Maximum Reverse Speed in Percentage (usually -100%) P453 = -100 P060 = Return to Parameter Menu P060 = 1 P128 = Maximum Motor Current Options: P128 = P102 P128=1.1*P102 P128 = xxxx P128=1.5*P102 P462 = Acceleration Time in seconds P462 = xxxx P464 = Deceleration Time in seconds P464 = xxxx P443i2(Index2) = 11 Configures drive for analog input (0-10Vdc) to be active at P443i2= 11 terminals X101 pin#15 and pin#16 If 4-20mA is required closed CUVC board mounted jumper S3, position 1 and 2
ページ20に含まれる内容の要旨
Connect External Wiring as connection diagram. Customer Connection Points Internal Connections Step 1: Dry set of contacts between terminals X101, pin#1 and pin#5 for Local/Remote Mode Selection. Jumper if not required. Step 2: Dry set of contacts between terminals X101, pin#1 and pin#8 for Coast to Stop Selection. Jumper if not required. Step 3: Dry set of contacts between terminals X101, pin#1 and pin#9 for Source of Main Start/Stop Selection. Step 4: Dry set of contacts between terminals
ページ1に含まれる内容の要旨
Quick Startup Guide for
SIMOVERT MASTERDRIVES
6SE70 VC
Vector Control
Section 1: Parameterization of Base Drive
Section 2: Parameterization of Rectifier
Section 3: Simovis Trace Setup Method
Section 4: When Should a Drive be re-Tuned
DROM-02069
ページ2に含まれる内容の要旨
We reserve the right to modify functions, technical data, standards, drawings and parameters. We have checked the contents of this document to ensure that they coincide with the described hardware and software. However, deviations cannot be completely ruled-out, so we cannot guarantee complete conformance. However, the information in this document is regularly checked and the necessary corrections will be included in subsequent editions. We are thankful for any recommendations or suggestions.
ページ3に含まれる内容の要旨
NOTE: These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, please contact your local Siemens office. Further, the contents of these instructions shall neither become a part of nor modify any prior or existing agreem