ページ1に含まれる内容の要旨
HANGING AIR FILTER
WITH REMOTE
MODEL G0572
INSTRUCTION MANUAL
COPYRIGHT © JANUARY, 2005 BY GRIZZLY INDUSTRIAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#BL6810 PRINTED IN CHINA
ページ2に含まれる内容の要旨
WARNING Some dust created by power sanding, sawing, grind- ing, drilling, and other construction activities contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are: • Lead from lead-based paints. • Crystalline silica from bricks, cement, and other masonry products. • Arsenic and chromium from chemically treated lumber. Your risk from these exposures varies, depending on how often yo
ページ3に含まれる内容の要旨
Table of Contents INTRODUCTION ............................................................................................................................... 2 Foreword .................................................................................................................................... 2 Contact Info ................................................................................................................................ 2 SECTION 1: SAFETY .................................
ページ4に含まれる内容の要旨
INTRODUCTION Foreword Contact Info We are proud to offer the Model G0572 Hanging If you have any comments regarding this manual, Air Filter with Remote. This machine is part of please write to us at the address below: a growing Grizzly family of fine woodworking machinery. When used according to the guide- Grizzly Industrial, Inc. C lines set forth in this manual, you can expect /O Technical Documentation years of trouble-free, enjoyable operation and P.O. Box 2069 proof of Grizzly’s commi
ページ5に含まれる内容の要旨
MACHINE DATA SHEET Customer Service #: (570) 546-9663 • To Order Call: (800) 523-4777 • Fax #: (800) 438-5901 MODEL G0572 HANGING AIR FILTER WITH REMOTE Overall Dimensions: 1 Unit Dimensions (L x W x H) ...................................... 26" x 19 ⁄4" x 15" Shipping Weight .........................................................................64 lbs. Installed Weight ......................................................................... 55 lbs. Capacities: Air Flow at Low Speed ....
ページ6に含まれる内容の要旨
SECTION 1: SAFETY For Your Own Safety, Read Instruction Manual Before Operating this Machine The purpose of safety symbols is to attract your attention to possible hazardous conditions. This manual uses a series of symbols and signal words which are intended to convey the level of importance of the safety messages. The progression of symbols is described below. Remember that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measure
ページ7に含まれる内容の要旨
Safety Instructions for Machinery 7. ONLY ALLOW TRAINED AND PROP- 16. MAKE SURE GUARDS ARE IN PLACE ERLY SUPERVISED PERSONNEL TO AND WORK CORRECTLY BEFORE OPERATE MACHINERY. Make sure USING MACHINERY. operation instructions are safe and clearly understood. 17. REMOVE ADJUSTING KEYS AND WRENCHES. Make a habit of checking for 8. KEEP CHILDREN AND VISITORS AWAY. keys and adjusting wrenches before turn- Keep all children and visitors a safe dis- ing machinery ON. tance from the work area. 18
ページ8に含まれる内容の要旨
Additional Safety for Hanging Air Filters 1. FILTER CAPABILITIES. DO NOT allow 6. MINIMIZING DUST EXPOSURE. Use a this air filter unit to operate in an environ- respirator along with a dust collection sys- ment that has volatile fumes from fuels, tem when operating woodworking machin- paints, pesticides, chemicals, smoke; and ery, and keep the filters of your air filter never operate in an environment that has unit clean for optimum performance to particles of silica, metal, asbestos, or min
ページ9に含まれる内容の要旨
SECTION 2: CIRCUIT REQUIREMENTS Plug Type 110V Operation The Model G0572 is supplied with a 5-15 plug, similar to Figure 1. Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so. Amperage Draw 1 The ⁄5 HP motor on the Model G0572 will draw the following amps on the highest setting: Motor Load ..............................................3 Am
ページ10に含まれる内容の要旨
Grounding Extension Cords We do not recommend using an extension cord In the event of an electrical short, grounding with most equipment because the cord can reduces the risk of electric shock by providing generate heat that may cause fire or circuit a path of least resistance to disperse electric damage. If you must use an extension cord, use current. This tool is equipped with a power cord the guidelines below. that has a plug with an equipment-grounding prong. The outlet must be p
ページ11に含まれる内容の要旨
SECTION 3: SET UP Set Up Safety Items Needed For Set Up The following items may be needed to complete This machine presents the set up process, depending upon how you plan serious injury hazards to set up your air filter, but are not included: to untrained users. Read through this entire manu- DESCRIPTION QTY al to become familiar with • Phillips Head Screwdriver .......................... 1 the controls and opera- • Safety Glasses (for each person) .............. 1 tions before starting
ページ12に含まれる内容の要旨
Inventory A After all the parts have been removed from the two boxes, you should have the following items: Components (Figure 2) QTY C A. Model G0572 Hanging Air Filter ................. 1 B B. Primary Filter (5-Micron, Pleated-Type) ..... 1 C. Secondary Filter (1-Micron, Bag-Type) ...... 1 Remote Control and Mounting Hardware (Figure 3) D. Hand-Held Remote Control Unit ................ 1 Figure 2. Model G0572 Hanging Air Filter and E. AAA Batteries .........................................
ページ13に含まれる内容の要旨
Hardware Recognition Chart -11- G0572 Hanging Air Filter with Remote
ページ14に含まれる内容の要旨
Shop Preparation Site Planning Machine Mobility Site planning is an important step to maximize the The Model G0572 has a balanced fan and uses effectiveness of the hanging air filter. Air circulation digital components that are sensitive to jarring. must be thought out and all obstructions to the air Move this air filter unit with care, and do not drop path considered. or handle it roughly. Think of air circulation in terms of the circular Operating Location motion of the air before and
ページ15に含まれる内容の要旨
Figure 5 shows an example of poor air circulation, Filter Capacity where the air filter is placed too close to obstruc- tions. In this situation, the velocity of the air is lost and circulation is diminished. The G0572 Hanging Air Filter with Remote will recirculate the entire volume of air in a room measuring 25' X 25' X 8' approximately 12 times in one hour. We recommend that the volume of air in your room be recirculated at least 6-8 times every hour. To calculate the recirculating ra
ページ16に含まれる内容の要旨
Dust System Mounting Preparation When used in conjunction with a dust collector system, the Model G0572 filter efficiently removes It is very important that the hanging air filter most fine wood particles in the air that many dust be supported properly. Please use these guide- collectors cannot. lines when preparing to mount the unit: • For the sake of clarity, the face where the mounting eye bolts and flush mount USE the correct dust collection system in flange brackets attach will b
ページ17に含まれる内容の要旨
Beginning Mounting Keep the air filter unit ! unplugged during all You can install the air filter unit one of the installation procedures. following ways: Ignoring this warning may result in serious personal • Table-Top Mount: Use the rubber feet and/or injury to you or others! the flush mount flange brackets (see Figures 6 & 7) for a table-top application). • Hanging Mount: Use the eye bolts (see Figures 6 & 7) for a high ceiling application. Refer to Page 16. Table-Top Mount • Flus
ページ18に含まれる内容の要旨
To make the unit operate at the optimum height Flange Bracket Mounting Rubber Feet of 7' from the floor, you can install the air filter Holes unit in your shop by hanging it by chain, cable, or steel strapping. ONLY hang the air filter to load bearing ceil- ing studs or joists that can hold at least 100 lbs. DO NOT mount the unit to sheet rock, pressboard, paneling, or honeycomb ceil- ing panels with expansion-type fasteners like the ones shown in Figure 9. The fasten- ers can tear out a
ページ19に含まれる内容の要旨
2. Remove the plug screw. Retain the screws, Flush Mount because if you remove the eye bolts for the flush mounting configuration, you must reinstall these screws to seal the air filter unit. (Figure Components and Hardware Needed Qty 10). Mounting Brackets ............................................. 4 1 1 Hex Bolts ⁄4"-20 X ⁄4" ........................................ 8 Optional Plug Screw 1 ⁄4" Lag Bolts ...................................................... 4 1 ⁄4" Nuts .............
ページ20に含まれる内容の要旨
1 2. Drill the bolt pattern to accept at least ⁄4" lag 4. Install the flat washers and the hex bolts to 1 bolts for studs; or use ⁄4" nuts, bolts, and secure the flange brackets to the unit (Figure washers for mounting to supports. 14). 3. Position the flange bracket under the air filter Flange Bracket unit lip at the mounting hole location (Figure Mounted Under Lip 12). For permanent table-top mounting, use the lower-lip holes (Figure 13). Lip Mounting holes Flange Bracket Figure 14. F