ページ1に含まれる内容の要旨
Models
SG-WAC-15ESE
SG-WAC-18ESE
SG-WAC-25ESE
Electronic Window Air Conditioner
Operating Instructions
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and seria
ページ4に含まれる内容の要旨
ELECTRICAL REQUIREMENTS The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front). Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord. Wiring Requirement Power Supply Cord Electrical Shock Hazard 208~230 Volt (197.2 min. - 253 max.) Plug into a grounded 3 prong outlet. Do not remove the gr
ページ5に含まれる内容の要旨
PARTS LIST 25ESE 15/18ESE 25ESE 15/18ESE WINDOW SASH SEAL ROUND HEAD SAFETY LOCK AND 3/4" ROUND-HEAD SCREW TOP ANGLE FOAM GASKET WASHER HEAD LOCKING SCREW (on 25ESE models) FRAME ASSEMBLY (LEFT) SIDE RETAINER 3 7/8 SEAL-BOTTOM RAIL TO UNIT 1/2" LONG SCREWS AND FRAME LOCKNUTS ASSEMBLY (RIGHT) WINDOW SUPPORT LOCKNUT BRACKET TOOLS NEEDED 3/4" LONG FLAT HEAD BOLT SILLANGLE Large Flathead Screwdriver BRACKET Tape Measurer Adjustable Wrench or Pliers Pencil Level Socket Wrenches Phillips H
ページ6に含まれる内容の要旨
SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the unit. Model SG-WAC-15ESE SG-WAC-18ESE SG-WAC-25ESE Power Supply (Ph/V/Hz) 1/115/60Hz 1/230-208/60Hz 1/230-208/60Hz Dehumidifying Capacity (Pints/Day) 91.2 129.6 192 Rated Cooling Capacity (BTU
ページ7に含まれる内容の要旨
INSTALLATION & ASSEMBLY INSTRUCTIONS Window Preparation Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit. Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made to fit inside a standard double-hung window. Make sure the window i
ページ8に含まれる内容の要旨
INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING REMOVE CHASSIS 1. Pull down the front panel and remove the filter (FIG. 1 below) 2. Lift the front panel upwards to remove and place to the side. FIG. 2 FIG. 1 3. Locate the four faceplate screws and remove. These screws will need to be re-installed prior to mounting the air con- ditioner (FIG. 2 above) 4. After removing the screws, gently pull away the faceplate from the air conditioner cabinet (FIG. 3 & 4). FIG. 3 FIG. 4 5. Remove
ページ9に含まれる内容の要旨
ASSEMBLY & INSTALLATION (CONT.) Top Angle Rail and Side Bracket Installation FIG. 9 1. Place the air conditioner on a hard flat surface. 2. Locate the foam gasket and top angle rail 3. Attach the foam gasket to the top angle rail. 4. Install top angle side to cabinet as shown in FIG. 7. TOP VIEW Foam Gasket and Top Angle Rail FIG. 7 8. Once the window panels are correctly installed, for 25K insert the washer head locking screws on the top rail and frame. Do not tighten all the way at t
ページ10に含まれる内容の要旨
ASSEMBLY & INSTALLATION (CONT.) Install Support Brackets Extend the Accordion Panels 1. Hold each support bracket flush against the outside of 1. Carefully raise the window to expose the accordion the window sill. Tighten each bracket to the bottom of panel and panel frame. Loosen the locking screws so the cabinet as shown below. Mark the brackets at top the accordion panels slide easily. lever of the window sill and then remove. Locking Screw For 24K 3/4" Round- Head Screw for 14/18K Mar
ページ11に含まれる内容の要旨
ASSEMBLY & INSTALLATION (CONT.) Installing the Chassis into the Cabinet THRU-THE-WALL INSTALLATION 1. Team lift (two people) the air conditioner chassis and carefully slide it into the cabinet. Let the front of the air NOTE: Consult local building codes prior to installation conditioner hang out approximately 6”. and/or a qualified carpenter. 2. DO NOT PUSH ON THE CONTROLS OR FINNED COILS. Select the Wall Location 3. Be sure the chassis is firmly seated in the back of the This air
ページ12に含まれる内容の要旨
ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.) Carefully measure and cut an opening with the following NOTE: If wall thickness is 8-12” or more, add aluminum dimensions depending on your model (FIG. 1 & 2). flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall. WIDTH “X” = inside model plus twice the thickness of the framing material used. HEIGHT “Y” = inside model height plus twice the thickness of framing material
ページ13に含まれる内容の要旨
ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.) Refer to the SUPPORT BRACKET ASSEMBLY in the MASONRY CONSTRUCTION WINDOW MOUNTING section to assemble the support brackets. A wooden strip nailed to the outside wall should 1. Cut or build a wall opening in the masonry wall similar be used in conjunction with the angled sill support brack- to the frame construction (refer to the THRU-THE- ets. WALL installation for a wall thickness greater than 8 1/2”).. 2. Secure the cabinet in place u
ページ14に含まれる内容の要旨
USING YOUR AIR CONDITIONER 1. Power Button: Turns the air conditioner on and Electronic Control Panel & Remote Control off 2. Digital Display: Displays the current room tem- perature or the amount of time left on the timer. When the light is on the unit is in Shows the Set Temp when setting the tempera- This display always shows the room temperature or timer set mode. temperature except when setting ture. Shows the Timer Set when setting the timer. the Set temperature or the Time
ページ15に含まれる内容の要旨
USING YOUR AIR CONDITIONER (Cont.) • Freezing Conditions: This is a cooling only air • Fan Only Mode: Use Fan Only mode at Low, conditioner. It is not designed for freezing outdoor Med, or High fan speed to provide air circulation conditions. It must not be used in freezing outdoor and filtering without cooling. Since fan only setting conditions. do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in • Remote Control: To ensure
ページ16に含まれる内容の要旨
Cabinet Cleaning CARE AND CLEANING To clean the air conditioner cabinet: Clean your air conditioner to keep it looking new and to minimize dust build up. • Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front panel of Air Filter Cleaning the air conditioner may be dusted with an oil- The air filter should be checked at least once free cloth or washed with a cloth dampened in every month to see if it needs cleaning. Trapped a solution of warm water and
ページ17に含まれる内容の要旨
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged • Make sure the air conditioner is plug is pushed completely into the outlet • Check the house fuse/circuit The fuse is blown/circuit breaker is breaker box and replace the fuse tripped. or reset the breaker. • The unit will automatically re-start Power Failure when power is restored. • There is a protective time delay (app
ページ18に含まれる内容の要旨
TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS Water is dripping outside Hot and Humid weather. • This is normal Water is dripping inside the room The air conditioner is not correctly • For proper water drainage, make tilted outside. sure the air conditioner is slightly tilted downward from the front of the unit to the rear. Water collects in the base pan Moisture removed from the air is • This is normal for a short period in draining into the base pan. are
ページ19に含まれる内容の要旨
WARRANTY One Year Limited Warranty Soleus International, Inc. warrants the accompanying Soleus Air Powered by Gree Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International will, at its option, either repair or replace it, free of charge within a reasonable tim
ページ20に含まれる内容の要旨
66129903756