ページ1に含まれる内容の要旨
Product Manual
Cheetah 15K.7 FC
Standard models Self-Encrypting Drive models
ST3600057FC ST3600957FC
ST3450857FC ST3450757FC
ST3300657FC ST3300557FC
SED FIPS 140-2 models
ST3600857FC
ST3450657FC
ST3300457FC
100516225
Rev. E
December 2012
ページ2に含まれる内容の要旨
© 2012 Seagate Technology LLC. All rights reserved. Publication number: 100516225, Rev. E December 2012 Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. Cheetah and SeaTools are either trademarks or registered trademarks of Seagate Technology LLC or one of its affiliated companies in the United States and/or other countries. The FIPS logo is a certification mark of NIST, which does not imply produc
ページ3に含まれる内容の要旨
CONTENTS SEAGATE® TECHNOLOGY SUPPORT SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.0 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.0 APPLICABLE STANDARDS AND REFERENCE DOCUMENTATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1 STANDARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ページ4に含まれる内容の要旨
CONTENTS 6.2.2 Power sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 6.2.3 Current profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 6.3 POWER DISSIPATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 6.4 ENVIRONMENTAL LIMITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ページ5に含まれる内容の要旨
CONTENTS 11.1.7 Fibre Channel Process Login Accept. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 11.1.8 Fibre Channel fabric login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 11.1.9 Fibre Channel fabric accept login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 11.1.10 Fibre Channel Arbitrated Loop options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 11.2 DUAL PORT SUPPORT. . . . . . .
ページ6に含まれる内容の要旨
® Seagate Technology Support Services For information regarding online support and services, visit http://www.seagate.com/www/en-us/about/contact_us/ Available services include: • Presales & Technical support • Global Support Services telephone numbers & business hours • Authorized Service Centers For information regarding Warranty Support, visit http://www.seagate.com/support/warranty-and-returns/ For information regarding data recovery services, visit http://www.seagate.com/services-software/d
ページ7に含まれる内容の要旨
1.0 SCOPE ® ® This manual describes Seagate Technology LLC, Cheetah 15K.7 FC (Fibre Channel) disk drives. Cheetah 15K.7 FC drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications to the extent described in this manual. The Fibre Channel Interface Manual (part number 100293070) describes the general Fibre Channel Arbitrated Loop characteristics of this and other Seagate Fibre Channel drives. The Self-Encrypting Drive (SED) Users Guide, part number 100
ページ8に含まれる内容の要旨
2.0 APPLICABLE STANDARDS AND REFERENCE DOCUMENTATION The drive has been developed as a system peripheral to the highest standards of design and construction. The drive depends upon its host equipment to provide adequate power and environment in order to achieve optimum performance and compliance with applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temperature regulation. In p
ページ9に含まれる内容の要旨
2.1.2 Electromagnetic compliance Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking and C-Tick Marking. The drive was tested in a representative system for typical applications. The selected system represents the most popular characteristics for test platforms. The system configurations include: • Typical current use microprocessor • Keyboard • Monitor/display • Printer • Mouse Although the test system with this Seagate model complies w
ページ10に含まれる内容の要旨
2.3 REFERENCE DOCUMENTS ANSI Fibre Channel Documents X3.230-1994 FC Physical and Signaling Interface (FC-PH) X3.297.1997 FC-PH-2 Fibre Channel Physical and Signaling Interface-2 X3.303.1998 FC-PH-3 Fibre Channel Physical and Signaling Interface-3 X3.272-1996 FC Arbitrated Loop (FC-AL) X3.269-1996 Fibre Channel Protocol for SCSI (FCP) NCITS TR-19 Private Loop SCSI Direct Attach (PLDA) NCITS TR-20 Fabric Loop Attachment (FC-FLA) SFF-8045 Specification for 40-pin SCA-2 Connector with Par
ページ11に含まれる内容の要旨
3.0 GENERAL DESCRIPTION Cheetah 15K.7 FC drives provide high performance, high capacity data storage for a variety of systems including engineering workstations, network servers, mainframes, and supercomputers. Cheetah 15K.7 FC drives support 4-Gbit Fibre Channel. Cheetah 15K.7 FC drives support the Fibre Channel Arbitrated Loop (FC-AL) and SCSI Fibre Channel Protocol as described in the ANSI specifications, this document, and the Fibre Channel Interface Manual which describes the general
ページ12に含まれる内容の要旨
3.1 STANDARD FEATURES Cheetah 15K.7 FC drives have the following standard features: • 4-Gbit Fibre Channel interface • Integrated dual port FC-AL controller • Concurrent dual port transfers • Support for FC arbitrated loop, private and public attachment • Differential copper FC drivers and receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to 32 initiators • Drive selection ID and con
ページ13に含まれる内容の要旨
3.2 MEDIA DESCRIPTION The media used on the drive has an aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for improved durability and environmental protection. 3.3 PERFORMANCE • Programmable multi-segmentable cache buffer • 400 Mbytes/sec maximum instantaneous data transfers per port • 15k RPM spindle; average latency = 2.0 msec • Command queuing of up to 128 commands • Background processing of queue • Supports start and stop comma
ページ14に含まれる内容の要旨
3.5.1 Programmable drive capacity Using the Mode Select command, the drive can change its capacity to something less than maximum. See the Mode Select Parameter List table in the SCSI Commands Reference Manual. Refer to the Parameter list block descriptor number of blocks field. A value of zero in the number of blocks field indicates that the drive shall not change the capacity it is currently formatted to have. A number in the number of blocks field that is less than the maximum number of
ページ15に含まれる内容の要旨
4.0 PERFORMANCE CHARACTERISTICS This section provides detailed information concerning performance-related characteristics and features of Cheetah 15K.7 FC drives. 4.1 INTERNAL DRIVE CHARACTERISTICS ST3600057FC ST3450857FC ST3300657FC ST3600957FC ST3450757FC ST3300557FC ST3600857FC ST3450657FC ST3300457FC * Drive capacity 600 450 300 Gbytes (formatted, rounded off value) Read/write data heads 8 6 4 Tracks per inch 165,000 165,000 165,000 TPI Peak bits per inch 1,361 1,361 1,361 KBPI 2 Are
ページ16に含まれる内容の要旨
4.2.2 Format command execution time (minutes) When changing sector sizes, the format times shown below may need to be increased by 30 minutes. ST3600057FC ST3450857FC ST3300657FC 119 88 58 Maximum (with verify) 60 44 29 Maximum (without verify) Note. There is approximately a 1.5 increase in time to format a SED drive versus a non-SED drive of the same capacity. 4.2.3 General performance characteristics Sustainable disk transfer rate*: Minimum 122 Mbytes/sec (typical) Maximum 204 Mbytes/s
ページ17に含まれる内容の要旨
4.4 PREFETCH/MULTI-SEGMENTED CACHE CONTROL The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and
ページ18に含まれる内容の要旨
4.5.1 Caching write data Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is stored while the drive performs the Write command. If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made available for future read cache hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation scheme is set up or changed indep
ページ19に含まれる内容の要旨
5.0 RELIABILITY SPECIFICATIONS The following reliability specifications assume correct host and drive operational interface, including all interface timings, power supply voltages, environmental requirements and drive mounting constraints. 8 Seek error rate: Less than 10 errors in 10 seeks Read Error Rates 12 Recovered Data Less than 10 errors in 10 bits transferred (OEM default settings) 16 Unrecovered Data Less than 1 sector in 10 bits transferred 21 Miscorrected Data Less than 1 sector
ページ20に含まれる内容の要旨
5.2 RELIABILITY AND SERVICE You can enhance the reliability of Constellation ES.3 SAS disk drives by ensuring that the drive receives adequate cooling. Section 6.0 provides temperature measurements and other information that may be used to enhance the service life of the drive. Section 10.2 provides recommended air-flow information. 5.2.1 Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF) These drives shall achieve an AFR of 0.55% (MTBF of 1,600,000 hours) when operated i