PORTABLE AIR CONDITIONER
MAC 7500 Owner’s Manual
• Air Conditioner
• Dehumidifier
• Oscillating Fan
Please read this owner’s manual
POWERED BY
carefully before operating the unit.
66126113.p65 17 02-12-21, 15:44
ページ2に含まれる内容の要旨
INTRODUCTION Thank you for purchasing the Mac 7500 portable air-conditioner. This unit is designed for improving living and working comfort by providing cooling, dehumidifying and fan functions only with a minimum installation required. With its whisper quite operation and attractive design, you will enjoy the convenience and comfort that this unit provides for many years to come. When operating as an air conditioner, this unit is designed for spot cooling or cooling for a room 1 no larger than
ページ3に含まれる内容の要旨
• Unplug unit from the electrical outlet when not in use and before cleaning it. • Do not use an adapter plug extension cord. • Do not use near gas appliances, open flames (fireplaces) or near the vicinity flammable liquids. • Do not operate this unit if it had a damaged cord or plug or if it is not warking properly, or has been dropped or damaged in any manner. Take the unit to the nearest authorized. Ser- vice Facility for examination, repair or electrical/mechanical adjustment. • The use of a
ページ4に含まれる内容の要旨
PACKAGE CONTAINS: – Mobile Air Conditioner LITHIUM BATTERY 3V Air Exhaust Duct Window Kit - 3 Sliding Panels Exhaust Duct Window Kit Adapter Window Kit Fastener Screws (4) Romote Controller User Manual NAMES OF PARTS FRONT control panel air flow guider swing louver handle front air outlet grill water tank cable(power castol cord and plug) BACK upper air inlet grill Outlet for Continuous Drainage hot air outlet grill Use exclusively for continuous drainage. Don't pull out the outlet except low
ページ5に含まれる内容の要旨
Exhaust Duct Exhaust Duct Unit Terminal End Window Kit Adaptor Window Kits Exhaust Duct When you use the unit as an air conditioner, the hot exhaust air must be directed out of the room. The exhaust duct is used to allow the hot air out. DO NOT INSTALL OR USE THE EXHAUST DUCT WHEN THE UNIT IS OPERATED AS A DEHUMIDIFIER OR FAN. a) Slide exhaust connector all the over the hot Air outlet grill. b) Mount the external and of the ex- 1 haust duct onto a bole of 5 / " (132 4 mm) on the wall for optiona
ページ6に含まれる内容の要旨
c) Or connect the window kit adaptor to the external end of the exhaust duct for a window or sliding door hot air outlet installation. NOTE: In order to increase the efficiency, the exhaust duct should be keep as short and straight as possible. The exhaust hose can be cut shorter by unthreading either end of the exhaust duct counter clockwise. It is not recommended to increase the manufacturer’s length of the exhaust hose. This may impede or damage the unit. Window Kit Installation a) Open windo
ページ7に含まれる内容の要旨
CONTROL PANEL REMOTE CONTROLLER 6 66126113.p65 6 02-12-21, 15:44
ページ8に含まれる内容の要旨
OPERATION USING CONTROL PANEL 1) For Manual Mode: Press the Mode Button a) Cool - Cooling function on indicator. b) Dry - Dehumidify function on indicator. c) Fan - Fan on indicator. 2) For Cooling Operation: a) Be sure that the drain tank is properly placed in the unit. b) Install the exhaust duct properly. c) Plug the Power Cord to the power outlet. d) Press the Mode Button until the cool indicator is on. NOTE: During hot days, the unit will cool off the room most efficiently by setting the
ページ9に含まれる内容の要旨
4) Fan Operation: a) Plug the Power Cord to the power outlet. b) Turn on the unit by pressing the ON/OFF Button on the control panel. c) Press the Mode Button until ‘FAN’ indicator is on. d) Select the fan speed by pressing the Fan Speed Button. NOTE: When the unit is running on fan mode, the exhaust duct is inoperative and is not required. OPERATION USING REMOTE CONTROLLER The remote controller provided with the unit may operate this portable air conditioner. The – remote controller uses on
ページ10に含まれる内容の要旨
CONDENSATE WATER DRAINAGE 1) Internal Water Tank When operating in cooling or dehumidifying mode, the condensate water will drain into the internal water tank. Depending on the surrounding humidity, the unit can continu- ously operate for 2 to 12 hours before the internal water tank is full. When the internal water tank gets full, a beep slarm will sound eight times for 15 seconds. The compres- sor stops running and the fan will continue to run in the set speed for three minutes before the ent
ページ11に含まれる内容の要旨
Do not remove the water tank when the unit is in use. Always turn “Off” the unit before removing water tank. Periodically inspect and clean the drain valve to prevent clogging. METHOD OF CONTINUOUS DRAINAGE: 1. Slide out drain valve from the left side of the unit. 2. Connect a rubber pipe to the valve (not included). 3. Make sure the rubber pipe drains downward. 10 66126113.p65 10 02-12-21, 15:44
ページ12に含まれる内容の要旨
AIR FILTER • Soleus Air recommends cleaning your air filter at least after every two weeks of use. Keep- ing your air filter clean will maximize the performance and life of this product. • Open the air filter cover on the left side of the unit (fig. a) • Remove the filter from the cover. • Wash the filter using warm water and a mild dishwasher detergent. • Allow to air dry before replacing in unit. Fig. a Water Tank • Using the handle, slowly remove water tonk from unit (fig. b). • Pour out any
ページ13に含まれる内容の要旨
NOTE: Be very careful when using an external water tank. The unit will not shut off automati- cally when an external water tank is full. Spill water can cause substantial damages to carpet, furniture and other valuables. Do not use lengthy drainage tabing without a condensate water pump. MAINTENANCE NOTE: Make sure power is off and the plug is pulled out of the power outlet before performing any maintenance activities. 1) Case a) Keep the unit from being exposed directly to the sun for possible
ページ14に含まれる内容の要旨
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE REMEDY Unit does not operate Unit is umplugged Secorely plug receptacle into the power outlet Drain tank is full Empty water tank Water tank not installed correctly Completely insert water tank Air exhaust is clogged Clear exhaust hose Unit does not cool There is a heating source in the room Turn down or off the other heating room source Air filter is dirty Clean or replace the air filter Air exhaust is not installed correctly Check the air exhaust duct
ページ15に含まれる内容の要旨
SPECIFICATIONS Model # MAC - 7500 ~ Power Source 115V / 60Hz Cooling capacity 7500 BTU/h Dehumidifyling capacity 24.0 liters/day Cooling input power 1000W Rated current 8.7A Refrigerant type HCFC R22 Refrigerant capacity 1.15 lb Operating Range - Cooling Max 95°F Dry Bulb - 71°F Wet Bulb (indoor air temperature) Min 67°F Dry Bulb - 57°F Wet Bulb Unit dimensions (H x D x W) 31" x 12.8" x 16.3" Specifications are subject to change without notice PRODUCT INFORMATION If you have problems or questi
ページ16に含まれる内容の要旨
DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TESTS FOR THE INFORMA- TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN. CONTACT INFORMATION For Optional and Spare Parts Technical Support Warranty Claim Customer Service Please Call (888) 8-Soleus Or Write to: Soleus International Inc. 9451 Telstar Ave. El Monte CA 91731 USA www.soleus