ページ1に含まれる内容の要旨
- Cooling
- Heating
- Dehumidifying
- Fan
Please read this owner’s
Manual carefully before
operating the unit.
ページ2に含まれる内容の要旨
TABLE OF CONTENTS INTRODUCTION………………………………………………………………… 2 IMPORTANT SAFEGUARDS………………………………………………..….2 PACKAGE CONTAINS…………………………………………………………..2 NAMES OF PARTS……………………………………………………………….3 INSTALLATION BEFORE USE……………………………..….………………4 CONTROL PANEL AND VFD DISPLAY………….…..……………………….5 CONTROL PANEL FUNCTIONS……………………………………………….6 OPERATION USING CONTROL PANEL………………………...….…..……7 OPERATION USING REMOTE CONTROLLER…………………………..…9 MAINTENANCE……………..……………………………….…..………………9 T
ページ3に含まれる内容の要旨
INTRODUCTION Thank you for purchasing Soleus Air LX-120/100 portable air-conditioner. This unit is designed for improving living and working comfort by providing cooling, dehumidifying and fan functions only with a minimum installation required. With its quite operation and attractive design, you will enjoy the convenience and comfort that this unit provides for many years to come. When operating as an air conditioner, this unit is designed for spot cooling or cooling for a room n
ページ4に含まれる内容の要旨
NAMES OF PARTS 4
ページ5に含まれる内容の要旨
Exhaust Duct Window Kits INSTALLATION BEFORE USE 1) Exhaust Duct When you use the unit as an air conditioner or a dehumidifier, the fresh outdoor air must be directed to the unit and the hot air must be exhausted out of the room to complete the air exchange. When the unit is operating on fan or heating models, no outdoor air exchange takes place. You do not need to hookup the window kits and exhaust hose when you use the unit as a
ページ6に含まれる内容の要旨
d) Mount terminal ends of the exhaust hoses to the unit. e) Open window or sliding door for approximately 5 inches (130 mm) f) Adjust the length of the window kit to the same length of the window or the sliding door. Use all three panels if necessary. Cut the window piece as needed to fit the length of your window or sliding door. Make sure that both holes on the main piece are not covered by other pieces. g) Place the window kit to the window or sliding door. Close the window or do
ページ7に含まれる内容の要旨
VFD DISPLAY Control Panel Functions 1) Power On/Off Control Starts or Stops the Unit 2) Mode Control Select the functions of the unit for: Fan Mode Air Conditioning Mode Heating Mode Dehumidifying Mode Auto Mode 3) Fan Speed Control Select the fan speed for: High Medium Low The fan speed can be visually distinguished by the speed of the digital air segments progressing out from the windmill fan image on the VFD display. 4) Temperature
ページ8に含まれる内容の要旨
The VFD display either in Celsius or Fahrenheit. Press /\ and \/ keys simultaneously to change the display from Celsius to Fahrenheit or vice verse. 5) Timer To program the timer, press Timer On key until the VFD display shows a flashing “ ”. Pressing either /\ or \/ keys to change the clock to the desired time for the unit being turned on. Press Timer Off key and the VFD display will show a flashing “ ”. Pressing either /\ or \/ keys to change the clock to the desi
ページ9に含まれる内容の要旨
Keep the windows and the doors closed to aid the effectiveness of the unit in removing the moisture from the room. NOTE: The unit will not perform dehumidification when the room temperature is lower than 61 degree. 3) Fan Operation a) Plug the Power Cord to the power outlet. b) Turn on the unit by pressing the On/Off Button on the control panel. c) Press the Mode Button until “ ” appears on the VFD display. d) Select the fan speed by pressing the Fan Button. NOTE: When the un
ページ10に含まれる内容の要旨
c) The fan motor of indoor unit runs in low speed d) When in cooling mode, within the first two hours, the temperature will be increased 1 ℉ per hour. Then temperature will be keeping at 2 ℉ higher than the originally set degree for 6 hours. 6 hours later, temperature will return to the originally set degree. e) When in heating mode, within the first 2 hours, temperature will be decreased 1 ℉ per hour. Then temperature will be keeping at 2 ℉ Lower than the original degree for 6 hours.6
ページ11に含まれる内容の要旨
Note: Make sure power is off and the plug is pulled out of the power outlet before performing any maintenance activities. 1) Clean or replace filter If the air filter is blocked with a lot of dust, the airflow volume will reduce. It is recommended to clean the filter once every two weeks or as needed. a) Pull up the filter from the filter compartment in the back of the unit. b) Wash the air filter by immersing it gently into warm (about 104 F) water with a neutral detergent. Rinse
ページ12に含まれる内容の要旨
DEHUMIDIFYING CAPACITY 50 pts/Day 60 pts/Day POWER COOLING 980W 1350W HEATING 1350W 1350W 3 3 AIR FLOW VOLUME 300m/h 300m /h POWER SOURCE 115 V~ 60 HZ 115 V~ 60 HZ 9/12 AMP 12/12AMP HEATING/COOLING HEATING/COOLING SOUND PRESSURE LEVEL 46 dB(A) 46 dB(A) NET WEIGHT 80 Lbs 82 Lbs OPERATING COOLING 60.8℉-108℉ 60.8℉-108℉ TEMPERATURE HEATING 23℉-89.6℉ 23℉-89.6℉ DIMENSIONS ASSEMBLED 18x32x18 Inch 18x32x18 Inch PACKAGE 20x35x23 Inch 20x35x23 Inch REFRIGERANT R22 R22 NOTE: 1) T
ページ13に含まれる内容の要旨
WARRANTY ONE YEAR LIMITED WARRANTY Soleus International Inc. warrants the accompanying Soleus Air MAC-12K/10K Mobile Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada. If the air conditioner exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of c
ページ14に含まれる内容の要旨
14