ページ1に含まれる内容の要旨
Wall Mounted Mini Split
Heat Pump
Air Conditioner
OPERATING AND INSTALLATION MANUAL
Model: KFHHP-18-ID / KFHHP-18-OD
Indoor Unit.
Outdoor Unit.
Thank you for selecting Soleus Air. To ensure proper
operation, please read this manual and keep it for
future reference.
ページ2に含まれる内容の要旨
TABLE OF CONTENTS USE AND MAINTENANCE……………………………..…………………………………….....1-14 Precautions on Use …………………………………………………………………..……………1-3 Specifications and Technical Data…………………………………………………………………...4 Instructions of Use…………………………………………………….…………………….……….5 Description of Air Conditioner Components………………………………………………...………6 Remote Control Operation…………………………………………………………………………7-8 How to Insert Batteries…………………………………………………….…………………………9 Cleaning and Maintenance…………………………………………....……………...…
ページ3に含まれる内容の要旨
Use and Maintenance ◆Precautions on Use Carefully read the following precautions before use Warning ★In case of malfunction (e.g. burnt ★To avoid electric shock. Never ★Do not cut or use damaged power smell), cut off the power supply operate the unit with wet hands. cords and control lines. immediately and then contact the Authorized Service Center (626-820- 1436). The malfunction continues, the air conditioner may be damaged. ★Never us
ページ4に含まれる内容の要旨
◆Precautions on Use ★Grounding: The unit must be properly grounded. ★Set the room temperature appropriately. The difference between indoor and outdoor temperature shall be 40 °F. ★To avoid the possibility of fire. ★Close all doors & windows for ★Never block the air inlet or outlet Never store chemicals or flammable efficient operation. of indoor and outdoor unit. items within 3.28 feet of the unit. Otherwise it may
ページ5に含まれる内容の要旨
◆Precautions on Use ★Adjust the air flow and direction properly. When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the direction of air flow. ★To avoid injury or damage, never stick your fingers or ★To avoid harm to your pets or plants, never direct the airflow at them. any other object into the unit. ★To avoid damage or electric shock, never spray liquid ★To avoid carbon m
ページ6に含まれる内容の要旨
◆Specifications and Technical Data Model KFHHP-18-ID / KFHHP-18-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 18000 / 5300 (1400-6000) Heating capacity(BTU/hr) & (Watts) 20000 / 6000 (1100-7000) Rated voltage 208-230V~ Rated Frequency 60Hz Cooling/Heating rated current(A) 10.6/10.6 Cooling/Heating rated power(W) 2440/2440 Cooling/Heating power input(W) 1350/1800 SEER 13.25 EER/COP(W/W) 3.93/3.22 HSPF 8.5 3 Recycling Air Volume(m /h) 800 F
ページ7に含まれる内容の要旨
◆Instructions for Use Principle and Special Functions during Cooling Mode Principle: The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temperature. Anti-freeze Function: If the air conditioner is running under low-temperature cooling mode, frost will appear on the surface of indoor heat exchanger. When the te
ページ8に含まれる内容の要旨
◆Description of Air-Conditioner Components (1) Front Panel (2) Guide Louver (3) Remote Sensor (4) Wall Pipe (5) Wrapping Tape (6) Drainage hose (7) Connection pipe - 6 -
ページ9に含まれる内容の要旨
◆Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will automatically resume its last running mode, and the outdoor unit will start there after. MODE Button: TEMP+ TEMP- Button: When the unit is turned on, press this Under the COOL, DRY, button. The AUTO, FAN or HEAT mode, COOL, DRY, FA
ページ10に含まれる内容の要旨
◆Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. SWING Button: ON/OFF Button Press once to have louvers Press ON. swing [oscillate]. Press Press OFF. twice in one second the panel light will turn on. Press twice again and the light will turn off. T-ON Button. When pressing this button once, enter into T-ON setting, the icon of T-ON flash, every press of T-OFF Button TIME+, the time of T-ON will
ページ11に含まれる内容の要旨
◆How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (Two AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • Don’t mix different batteries. • Remove batteries when not in use for a longtime. • The batteries can be used for about one year. • Keep remote at least 3.28 feet from TV’s and other electronic devices. When the wireless remote control is lost or broken, please use
ページ12に含まれる内容の要旨
◆Cleaning and Maintenance • Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might occur. • Liquids on the air conditioner may cause the risk of electric shock. Make sure not to spray wash your air conditioner in any case. • Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth or wet cloth soaked with neutral detergent to clean the air condi
ページ13に含まれる内容の要旨
◆Cleaning and Maintenance ③ Installing the air filter Mount the air filter in the direction of the arrows. Then, clamp the cover of front panel securely. Check before Seasonal Use ① Check the air inlet/outlet on indoor and outdoor units for any blockage. ② Check the grounding cable for reliability. ③ Check the batteries of remote control for replacement. ④ Check the mounting frame of outdoor unit for damage. If damaged, please contact t
ページ14に含まれる内容の要旨
◆Trouble-Shooting Do not repair by yourself. Incorrect repair may cause electric shock or fire, so please contact the Authorized Service Center for professional repair. Fault Cause Analysis Air conditioner does not run upon immediate restart after a To protect the air conditioner upon immediate restart stop. after a stop, the microcomputer control will delay the unit for 3 minutes before the air conditioner will run. Air conditioner blows out a ba
ページ15に含まれる内容の要旨
◆Trouble-Shooting Fault Cause Analysis Air conditioner does not run. • Power failure? • Circuit protection device tripped? • The voltage is too high or too low? ( Refer to Page 15). (To be tested by professional technicians). • Timer function is correctly used? ( Refer to Page 7). Air conditioner is poor in cooling (or heating) effect. • Is temperature setting proper? ( Refer to Page 7) • Is the air inlet or outlet of outdoor unit blocked? • Is the air
ページ16に含まれる内容の要旨
◆Trouble-Shooting Fault Cause Analysis No air blows out from indoor unit. • When the temperature of indoor heat exchanger is low during heating process, the indoor unit will stop blowing to prevent blowing of cold air (within 3 minutes). • Under dehumidify mode, the fan of the indoor unit might be stopped to prevent evaporation of condensing water and inhibit the rise of temperature. Moisture exists on outlet grill. • If the unit is run for extended periods
ページ17に含まれる内容の要旨
Installation Services ◆Precautions on Installation Important Caution 1. The air-conditioning unit must be installed by professional technicians in accordance with the state and local codes. 2. Contact the local installation and service agency before installation. 3. For relocation of the air conditioner to another position, please contact the local Authorized Service Center. Basic Requirements for Installation Position Installation at the following places may
ページ18に含まれる内容の要旨
◆Precautions on Installation 4. Ensure safe grounding and the grounding wire shall be connected with the special grounding equipment of the building and must be installed by professional technicians. In the fixed line there must be an electrical leakage protection switch and an air switch with sufficient capacity. The air switch shall also have the magnetic tripping and thermal tripping functions to achieve protection of both short-circuit and overload. 5. The minim
ページ19に含まれる内容の要旨
◆Installation Dimension Drawing - 17 -
ページ20に含まれる内容の要旨
◆Install Indoor Unit Installing Wall-Mounting Frame 1. Level with plumb line or spirit level. As the drain outlet is on left side, it is better that the left side shall be lower when adjusting the wall-mounted board. 2. Use screws to secure the wall-mounting frame on the wall. 3. After installation is completed, manually pull the wall-mounting frame to check if it is secured. The mounted frame shall be able to withstand the weight of an adult (132 lbs) and the