ページ1に含まれる内容の要旨
Models
GM-WAC-15ESE-C
GM-WAC-18ESE-C
Electronic Window A/C
Operating Instructions
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and seria
ページ4に含まれる内容の要旨
ELECTRICAL REQUIREMENTS The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front). Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord. Power Supply Cord GM-WAC-15ESE-C: NEMA 5-15P GM-WAC-18ESE-C: NEMA 6-15P Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do
ページ5に含まれる内容の要旨
PARTS LIST WINDOW SASH SEAL SAFETY LOCK AND 3/4" ROUND-HEAD SCREW TOP ANGLE FOAM GASKET FRAME ASSEMBLY (LEFT) SIDE RETAINER SEAL-BOTTOM RAIL TO UNIT 1/2" LONG SCREWS AND FRAME LOCKNUTS ASSEMBLY TOOLS NEEDED (RIGHT) Large Flathead Screwdriver WINDOW SUPPORT LOCKNUT BRACKET Tape Measurer 3/4" LONG FLAT HEAD BOLT SILLANGLE Adjustable Wrench or Pliers BRACKET Pencil Level Socket Wrenches Phillips Head Screwdriver Non-Hardware Packing List • Window Air Conditioner • AAA Batteries
ページ6に含まれる内容の要旨
SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. Model GM-WAC-15ESE-C GM-WAC-18ESE-C Power Supply (Ph/V/Hz) 1/115/60 1/230~208/60 Rated Cooling Capacity (BTU/h) 15,000 18,000/17,600 Cooling Power Input (Watts) 1400
ページ7に含まれる内容の要旨
INSTALLATION & ASSEMBLY INSTRUCTIONS Window Preparation Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit. Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made to fit inside a standard double-hung window. Make sure the window i
ページ8に含まれる内容の要旨
INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING REMOVE CHASSIS 1. Pull down the front panel and remove the filter (FIG. 1 below) 2. Lift the front panel upwards to remove and place to the side. FIG. 1 FIG. 1 FIG. 2 3. Locate the four faceplate screws and remove. These screws will need to be re-installed prior to mounting the air con- ditioner (FIG. 2 above) 4. After removing the screws, gently pull away the faceplate from the air conditioner cabinet (FIG. 3 & 4). FIG. 3 FIG. 4
ページ9に含まれる内容の要旨
INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING REMOVE CHASSIS 1. Pull down the front panel and remove the filter (FIG. 1 below) 2. Lift the front panel upwards to remove and place to the side. FIG. 2 FIG. 1 3. Locate the four faceplate screws and remove. These screws will need to be re-installed prior to mounting the air con- ditioner (FIG. 2 above) 4. After removing the screws, gently pull away the faceplate from the air conditioner cabinet (FIG. 3 & 4). FIG. 3 FIG. 4 5. Remove
ページ10に含まれる内容の要旨
INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING REMOVE CHASSIS 6. Remove the screws from the right side of the cabinet (FIG 7). FIG. 7 7. Hold the cabinet while pulling on the base handle to carefully remove the unit. Do not pull or lift near the top of the unit (FIG 8). FIG. 8 9
ページ11に含まれる内容の要旨
ASSEMBLY & INSTALLATION (CONT.) Top Angle Rail and Side Bracket Installation FIG. 9 1. Place the air conditioner on a hard flat surface. 2. Locate the foam gasket and top angle rail 3. Attach the foam gasket to the top angle rail 4. Install top angle side to cabinet as shown in FIG 7 TOP VIEW Foam Gasket and Top Angle Rail FIG. 7 Placing the Cabinet Inside the Window 1. Open the window and place the cabinet in the middle of the window sill. 2. Make sure t
ページ12に含まれる内容の要旨
Install Support Brackets Extend the Accordion Panels 1. Hold each support bracket flush against the outside of 1. Carefully raise the window to expose the accordion the window sill. Tighten each bracket to the bottom of panel and panel frame. Loosen the locking screws so the cabinet as shown below. Mark the brackets at top lever of the window sill and then remove. Mark the accordion panels slide easily. 2. Extend each panel to completely fill the width of the window. Tighten the lockin
ページ13に含まれる内容の要旨
ASSEMBLY & INSTALLATION (CONT.) Installing the Chassis into the Cabinet THRU-THE-WALL INSTALLATION 1. Team lift (two people) the air conditioner chassis and carefully slide it into the cabinet. Let the front of the air NOTE: Consult local building codes prior to installation conditioner hang out approximately 6”. and/or a qualified carpenter. 2. CAUTION: DO NOT PUSH ON THE CONTROLS OR FINNED COILS. Select the Wall Location 3. Be sure the chassis is firmly seated in the back of the
ページ14に含まれる内容の要旨
ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.) Carefully measure and cut an opening with the following NOTE: If wall thickness is 8-1/2” or more, add aluminum dimensions depending on your model (FIG. 1 & 2). flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall. WIDTH “X” = inside model plus twice the thickness of the framing material used. HEIGHT “Y” = inside model height plus twice the thickness of framing material
ページ15に含まれる内容の要旨
ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.) Refer to the SUPPORT BRACKET ASSEMBLY in the MASONRY CONSTRUCTION WINDOW MOUNTING section to assemble the support brackets. A wooden strip nailed to the outside wall should 1. Cut or build a wall opening in the masonry wall similar be used in conjunction with the angled sill support brack- to the frame construction (refer to the THRU-THE- ets. WALL installation for a wall thickness greater than 8 1/2”).. FIG. 3 2. Secure the cabinet in
ページ16に含まれる内容の要旨
USING YOUR AIR CONDITIONER 3. Temperature Set: Use these buttons on the con- Electronic Control Panel & Remote Control trol panel and remote to increase or decrease the Set Temperature (the desired room temperature) in cooling,energy saver and dry mode. The SET NOTE: This display always shows the room temperature in Fan Mode except when setting the Set temperature or the Timer. light will light up when setting the temperature 4. Timer Set: Use these buttons on the control When the
ページ17に含まれる内容の要旨
OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 5. FAN - Press the FAN button to turn change the FAN options. You can choose between four speeds and auto mode. The fourth fan option is only available in cooling and energy saver modes. 6. IFEEL MODE - Press the IFEEL button to change the thermostat sensor from the air conditioner to the remote location. The air con- ditioner will cool the area depending on the location and set temperature of the remote control. Take the remote
ページ18に含まれる内容の要旨
OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 9. LOCK/UNLOCK- Press the “+” and “—” buttons simultaneously to lock and unlock the remote control. When the remote is locked, none of the functions or setting can be changed using the remote. 10. F° or C° - To switch between the F° or C° settings, press the MODE and “—” buttons a the same time. 11. DISPLAY LIGHTS- Hold the “+” and FAN buttons to turn the light s on the display ON or OFF. This can be done when the unit is on or off.
ページ19に含まれる内容の要旨
USING YOUR AIR CONDITIONER (Cont.) • Freezing Conditions: This is a cooling only air • Fan Only Mode: Use Fan Only mode at Low, conditioner. It is not designed for freezing outdoor Med, or High fan speed to provide air circulation conditions. It must not be used in freezing outdoor and filtering without cooling. Since fan only setting conditions. do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in • Remote Control: To ensure
ページ20に含まれる内容の要旨
Cabinet Cleaning CARE AND CLEANING To clean the air conditioner cabinet: Clean your air conditioner to keep it looking new and to minimize dust build up. • Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front panel of Air Filter Cleaning the air conditioner may be dusted with an oil- The air filter should be checked at least once free cloth or washed with a cloth dampened in every month to see if it needs cleaning. Trapped a solution of warm water and