Model No. GB-PAC-08E4
8,000 BTU Portable Air Conditioner
Operating Instructions
ページ2に含まれる内容の要旨
Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Portable Air Conditioner. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date p
ページ3に含まれる内容の要旨
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and eit
ページ4に含まれる内容の要旨
PRODUCT DIAGRAM Control Panel Louver Guides Louvers Casters Remote Control Holder Power Cord Filters Upper Air Intake Air Exhaust Vent Lower Air Intake 4
ページ5に含まれる内容の要旨
PACKAGE CONTENTS Portable Air Conditioner Exhaust Hose (1) Exhaust Hose Adapter (1) Window Kit Adapter (1) Hose Adapter (1) Remote Control & AAA Batteries (2 batteries) Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels) Drain Hose Assembly (drain pipe, clamp, hose clip, rubber plug, & screw) Owner’s Manual SPECIFICATIONS • The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F. • Noise level is measured at a distance of 3.28 ft a
ページ6に含まれる内容の要旨
PARTS & WINDOW KIT ASSEMBLY PARTS EXHAUST HOSE & ADAPTERS Exhaust Hose Adapter Exhaust Hose Hose Adapter ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit and exhaust hose must be installed. When the unit is operating in fan mode, the window kit and exhaust hose do not need to be installed . MOUNTING THE EXHAUST HOSE • Choose a suitable location, near a gro
ページ7に含まれる内容の要旨
SINGLE HOSE WINDOW KIT INSTALLATION This installation is OK The is a poor installation 22” When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If bending or an angle is necessary, use single 90° angles like the pictures above. Multiple bends will decrease performance and efficiency 7 26”
ページ8に含まれる内容の要旨
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS CONTROL PANEL & LED DISPLAY BUCKET FULL LIGHT COOL MODE LIGHT DRY MODE LIGHT REMOTE RECEIVER LED DISPLAY FAN MODE LIGHT TEMP SELECT BUTTON MODE BUTTON POWER BUTTON CONTROL PANEL OPERATING INSTRUCTIONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Selection - Press the MODE Button repeatedly t
ページ9に含まれる内容の要旨
REMOTE CONTROL OPERATING INSTRUCTIONS LCD DISPLAY and MODE LABELS NOTE: Heat mode is not available on the GB-PAC-08E4 POWER BUTTON MODE BUTTON TEMP SELECT BUTTONS SWING BUTTON FAN BUTTON (Not Available on GB-PAC-08E4) SLEEP BUTTON TIMER BUTTON 1) Power On and Off - Press the ON/OFF (POWER) button once to manually turn the unit on. Press the Power button once more to turn the unit off. When you manually power the unit on and off by pressing
ページ10に含まれる内容の要旨
REMOTE CONTROL OPERATING INSTRUCTIONS (Cont.) 5) Auto-on Timer: When the air conditioner is off, it can be set to automatically turn on in 30 minutes to 24 hours at the previous set mode and fan setting. To set the Auto-on Timer, press the TIMER button on the unit or remote control. Each touch of the +/- buttons on the remote will change the timer setting in 30 minute increments (.5 hours). The T-ON and H lights will blink while the Auto-on Timer is being set. Once the timer is set, press th
ページ11に含まれる内容の要旨
DRAINING COLLECTED WATER When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture that is unable to be evaporated is placed in a small bank up water tank in- side the unit. When this tank is completely full, an alarm will sound, the compressor will shut off, and the bucket full icon will light up on the control panel. To manually empty the tank, please follow the instructions below. Drain Hose Drain Pl
ページ12に含まれる内容の要旨
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from the filter compartment on the back of the unit. 2) Wash the air filter by immersing it gently into warm water with a neutral detergent.
ページ13に含まれる内容の要旨
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged or not • Make sure the air conditioner plug connected well. is pushed completely into the out- let • Check the house fuse/circuit breaker box and replace the fuse The fuse is blown/circuit breaker is or reset the breaker. tripped. • The unit will automatically re-start when power is restored. Power Failure • There is a protective ti
ページ14に含まれる内容の要旨
TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS The LCD Display is showing “E5” Low Voltage Protection • Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service. The LCD Display is showing “H8” The backup water tank is full • Drain the water tank • If the “H8” I still displayed after the water tank has been emptied, con- tact customer service. 14
ページ15に含まれる内容の要旨
WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of charge within a r
ページ16に含まれる内容の要旨