ページ1に含まれる内容の要旨
14,000 BTU Evaporative
Portable Air Conditioner and
14,200 BTU Heat Pump
OWNER’S MANUAL
Model # KY-36
Please read owner’s manual carefully before operating unit.
ページ2に含まれる内容の要旨
TABLE OF CONTENTS INTRODUCTION………………………………………………………………………………………………………………… 3 IMPORTANT SAFEGUARDS…………………………………………………………………………………………………… 3 LCDI POWER CORD AND PLUG……………………………………………………………………………………………… 4 PRODUCT DIAGRAM…………………………………………………………………………………………………………… 5 Front……………………………………………………………………………………………………………………….. 5 Back………………………………………………………………………………………………………………………... 5 Accessories……………………………………………………………………………………………………………….. 5 INSTALLATION…………………………………………………………………………………………………………
ページ3に含まれる内容の要旨
INTRODUCTION Thank you for purchasing the Soleus Air KY-36 14,000 BTU Portable Evaporative Air Conditioner and Heater. This unit is designed to improve indoor living and working comfort by providing cooling, dehumidifying, heating, and ventilation with minimal installation. This multi-functional unit operates as an air conditioner, dehumidifier, heater, and fan. Unlike traditional portables, there is no bucket to empty. The condensate water is evaporated and removed through the exhaust
ページ4に含まれる内容の要旨
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either l
ページ5に含まれる内容の要旨
PRODUCT DIAGRAM FRONT A. Control panel B. Vertical air louvers C. Air outlet D. Horizontal air louvers E. Casters F. Cable (power cord and plug) BACK A. Hot air outlet grill B. Lower air inlet grill ACCESSORIES Flexible exhaust hose with adapters • 3-piece set • stretches from 14 1/4” to 60 5/8” (36cm to 150cm) Window exhaust adapter Adjustable window slider kit • 2-piece set • adjusts 33 1/2” to 48 3/8” (85cm to 123cm) Drain tube Drain pan
ページ6に含まれる内容の要旨
INSTALLATION SELECTING THE LOCATION Place the unit in a flat location where the air outlets cannot be obstructed. Place the unit no less than 20” (50cm) away from a wall or other obstacle. MOUNTING THE EXHAUST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit. The exhaust hose should be kept as short and straight as possible. Take care to prevent any sharp bends in the exhaust hose, as this will trap hot e
ページ7に含まれる内容の要旨
WINDOW KIT INSTALLATION The window kit has been designed to fit into most standard vertical and horizontal windows. However, it may be necessary to modify some aspects of the installation process for certain window types. 1. Open the window or sliding door and adjust the length of the window kit to fit the opening. Mark and cut down a single panel of the window kit if necessary. 2. Place the window kit between the window and the window frame as shown in the images to the
ページ8に含まれる内容の要旨
CONTROL PANEL AND LED DISPLAY CONTROL PANEL TIMER Button Press this button to turn the timer on/off. Press this button to select among the modes of cooling, dehumidifying, fanning, or MODE Button heating. TEMP – Button This button decreases the room temperature/timer hours. TEMP + Button This button increases the room temperature/timer hours. ON/OFF Button Press this button to turn the unit on or off. FAN SPEED During the modes of cooling, heating and fanning, pr
ページ9に含まれる内容の要旨
OPERATION Plug the power cord into a properly grounded outlet. Do not connect the unit to an outlet that is also being used for other electrical appliances. The unit will beep after two seconds, then press the on/off button to begin operation. COOLING 1. Press the Cool Mode Button to choose the cooling function. 2. Repeatedly press the Temperature Buttons to set the desired room temperature (from 64-86°F). 3. Press the Fan Speed Button to choose the desired fan speed. 4. Press the
ページ10に含まれる内容の要旨
REMOTE CONTROL A. Temperature/Timer Adjustment Buttons B. Cooling Mode C. Dehumidifying Mode D. Fanning Mode E. Heating Mode F. On/Off Button G. Timer Button H. °C/°F Converting Button I. Airflow Button J. Fan Speed Buttons WATER DRAINAGE When the unit is in cooling mode, unwanted water is extracted from the air. Most of this water is used to cool the unit and make it run more efficiently. When the unit is used in extremely humid environments, water will collect in a wat
ページ11に含まれる内容の要旨
NOTE: In heating mode, the drain pipe accessory must be used to empty the water container. 1. Remove the rubber plug and keep for future use. 2. Connect the drain tube accessory to the drain hole. Place drain pan at end of drain tube; water will drain out automatically during operation. MAINTENANCE Always turn off and unplug the unit before cleaning to avoid electrical shock. CLEANING THE HOUSING Wipe the surface of the unit with a soft, damp cloth. Do not use abrasive ch
ページ12に含まれる内容の要旨
TROUBLESHOOTING Before seeking repair or service, please check the following: PROBLEM POSSIBLE CAUSE REMEDY Is the unit plugged in? Securely plug the power cord into the wall outlet. Is the main power supply on? Reestablish the main power supply. Unit does not operate or only runs in fan mode. Is the water container full indicator light on? Empty the water container. Is the timer set? Change timer settings. Is the air inlet or outlet blocked? Clear the blocking. Is there any other
ページ13に含まれる内容の要旨
TECHNICAL SPECIFICATIONS MODEL KY-36 Cooling Capacity 14,000 BTU/Hr Heating Capacity 14,200 BTU/Hr Dehumidifying Capacity 65 pts/day Cooling 1540 W Power Consumption Heating 1220 W Air Flow Volume 318 CFM Power Source 115 V / 60 HZ Cooling 13.4 A Rated Current Heating 10.6 A Cooling 64 ℉-100 ℉ Operating Temperature Heating 37 ℉-64℉ Sound Pressure Level <49 db(A) Weight 86 lbs Dimensions 14.4 x 22.4 x 30.5 inches (WxDxH) Refrigerant R22 NOTE: 1) Data may vary, plea
ページ14に含まれる内容の要旨
WARRANTY ONE YEAR LIMITED WARRANTY Soleus International Inc. warrants the accompanying Soleus Air KY-36 portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada. If the air conditioner exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of charge