UV-AIRE™ AIR PURIFYING SYSTEM
Model: UV-1500C
ITEMS INCLUDED IN KIT:
1-UV-Aire ™ UV-1500 units
10-Sheet metal mounting screws
2-drop ceiling cover plates
4-Wall and drop ceiling mounting
brackets
1-Ultra Violet lamp
1-Instruction Sheet
1-2x4 Electrical Conduit Box and Cover
4-Intake Air Filters
1-Carbon Filter
*For best results, operate the UV-1500 continuously 24 hours a day.
UV-C light inhibits the growth and reproduction of germs and bacteria in the air of a home or
office. T
ページ2に含まれる内容の要旨
I. INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. II. GENERAL INFORMATION Width Height Depth Lamp Intensity Recommended Model Volts Amps Watts Weight Hz at 1 meter Max Sq. Feet (Inches) (Inches) (Inches) 2 UV-1500C 120 1.3 60 130 37 μW/cm 1500 15.5 Lbs 18 23-3/4 6-5/16 WARNING: This product is designed for indoor in
ページ3に含まれる内容の要旨
IV. FOR AREA OR ROOM OPERATION 1. Place the UV-1500C in the desired area; plug the power cord into a standard 120-volt wall receptacle. 2. Turn the speed control knob clockwise to turn on the unit and to adjust the motor/fan speed to the desired airflow. (See Figure 1) 3. After the fan has started, the LED light will show a continuous “GREEN” color indicating proper unit operation. Figure 1 V. WALL MOUNTING OPTION (The UV-1500C is supplied with four mounting brackets to allow the unit to
ページ4に含まれる内容の要旨
3. Drill a 1/8” hole into the body of the UV-1500C at the marked locations. (See Figure 8) 4. Secure the extension covers the UV-1500C body with the supplied metal screws (See Figure 9 & 10). 5. Remove the two rubber feet on the side of the extension cover from bottom of unit to give necessary clearance for ceiling mount. (See Figure 11) Figure 8 Figure 11 Figure 9 Figure 10 6. Before hard wiring the UV-1500C, an electrical conduit box must be installed. Remove the wire cover in the back
ページ5に含まれる内容の要旨
11. Wire the UV-1500C in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. UNIT MUST BE GROUNDED. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over current circuit device rated at 15 amperes. Refer to Diagram A for wiring. Diagram A 11. Place cover over conduit box. (See Figure 16) 12. Apply power to the UV-1500C. Turn the speed control knob clockwise to turn
ページ6に含まれる内容の要旨
5. Remove lamp carefully, by sliding the lamp to the left through the hole on the left side of the chamber. After exposing the connection end of the lamp inside the chamber, remove the lamp through the front of the unit. NOTE: When replacing the lamp, always wipe off lamp with the supplied alcohol wipe after installing. 6. Replace the lamp by first guiding the end of the lamp through the hole on the left side of the UV chamber. Next, guide the other end of the lamp through the hole on the
ページ7に含まれる内容の要旨
Limited Warranty Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for eighteen (18) months from date of manufacturing by the consumer excepting the provisions numbered below. UV-LAMPS/BULBS Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall be free from defects in material and workmanship under normal use for ninety (90
ページ8に含まれる内容の要旨
Page 8 P/N 46448400 Rev D 09/05