         A Sierra Monitor Company
 
Driver Manual  
(Supplement to the FieldServer Instruction Manual) 
 
FS-8700-15 Modbus Daniels 
 
APPLICABILITY & EFFECTIVITY 
Effective for all systems manufactured after May 1, 2001                                                                                                                                                                                                                                                                                
                    
                    ページ2に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual       Index      TABLE OF CONTENTS  1. Modbus Daniels Description............................................................................................1  2. Driver Scope of Supply.....................................................................................................1  2.1. Supplied by FieldServer Technologies for this driver ...................................................1  rd 2.2. Provided by the Supplier of 3 Party Equipment.............
                    
                    ページ3に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual      Page 1 of 7      1.  Modbus Daniels Description   The Modbus Daniels driver allows the FieldServer to transfer data to and from devices over  either RS-232 or RS-485 using Modbus Daniels protocol. The FieldServer can only emulate a   Client.   Modbus Daniels is an inclusion into Modbus ASCII, allowing floats to be used. Modbus Daniels  is designed to support floats in the address range 7000 to 7999. The "Double" data type is not  supported. Other standard Mo
                    
                    ページ4に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual      Page 2 of 7      3. Hardware Connections  The FieldServer is connected to the Modbus Daniels device as shown in the connection  drawing.   Configure the Modbus Daniels device according to manufacturer’s instructions.                    4. Configuring the FieldServer as a Modbus Daniels Client  For a detailed discussion on FieldServer configuration, please refer to the FieldServer  Configuration Manual. The information that follows describes how to expand upo
                    
                    ページ5に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual      Page 3 of 7      factory defaults provided in the configuration files included with the FieldServer (See “.csv”  sample files provided with the FS).  This section documents and describes the parameters necessary for configuring the  FieldServer to communicate with a Modbus Daniels Server.    4.1. Data Arrays/Descriptors  The configuration file tells the FieldServer about its interfaces, and the routing of data  required. In order to enable the FieldServer fo
                    
                    ページ6に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual      Page 4 of 7      device is connected to the FS-X20 Serves: Serial Port  FieldServer  Protocol Specify protocol used Modbus_Daniels  110 – 115200, standard baud  Baud* Specify baud rate  rates only, 9600  Even, Odd, None, Mark,  Parity* Specify parity  Space  Data_Bits* Specify data bits 7, 8  Stop_Bits* Specify stop bits 1  Specify hardware  Handshaking* RTS, RTS/CTS, None  handshaking  Poll _Delay* Time between internal polls 0-32000 seconds, 1 second      
                    
                    ページ7に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual      Page 5 of 7      4.4. Client Side Map Descriptors  4.4.1. FieldServer Related Map Descriptor Parameters  Section Title  Map Descriptors  Column Title Function Legal Values  Name of this Map Up to 32 alphanumeric  Map_Descriptor_Name  Descriptor characters  Name of Data Array  One of the Data Array  where data is to be  Data_Array_Name names from “Data Array”  stored in the  section above  FieldServer  Starting location in 0 to maximum specified in  Data_Arra
                    
                    ページ8に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual      Page 6 of 7      4.4.4. Map Descriptor Example.    Section Title  Map Descriptors  Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name, Address, Length, Scan_Interval  CMD_AI, DA_AI, 0, RDBC, PLC 1, 30000, 20, 1s    The data array Note the use of The remote  where the read the RDBC Modbus Daniels  data will be function here device is  stored is which will specified here  specified here. cause this map with the node  This data array d
                    
                    ページ9に含まれる内容の要旨 
                    
                        FS-8700-15 Modbus Daniels Manual      Page 7 of 7      5. Advanced Topics  None.  6. Driver Notes  None.  7. Revision History  Driver  Document   Date Resp Comment  Version Revision  10/03/03 1.00d 0 JD Releasing  Updating formatting.  Adding Description  10/13/03 1.00d 1 MF  information – DUR0212  DUR0220, updated to new format, indicate  12/09/03 1.00d 2 DR  address ranges and data types supported  12/23/03 1.00d 3 JD Releasing                      FieldServer Technologies 1991 Tarob Court Mil