ページ1に含まれる内容の要旨
T E C H N O L O G I E S
User Guide
Z Snap-In Disk Array
(Z4SNHU3)
www.addonics.com
v8.1.11
Technical Support
If you need any assistance to get your unit functioning properly, please have your
product information ready and contact Addonics Technical Support at:
Hours: 8:30 am - 6:00 pm PST
Phone: 408-453-6212
Email: http://www.addonics.com/support/query/
ページ2に含まれる内容の要旨
Installation 1. Install drives as described in the Disk Installation section. 2. Connect the AC power adapter’s input to a wall outlet and the output cable to the Z Disk Array’s power connector. 3. Connect either the USB 3.0 or eSATA cable from the Z Disk array to the computer. 4. Configure the Port Multilpier as described in the Port Multiplier section. 5. Turn on the unit using the power switch on the back next to the power connector (see note). Power Switch Power Connector RAID Mode button
ページ3に含まれる内容の要旨
Port Multiplier Default factory DIP Switch setting: SW1 – RAID Setting DIP Switch BZS – Error buzzer function EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start. M2 – RAID mode 2 M1 – RAID mode 1 M0 – RAID mode 0 SW1 1 2 3 4 5 BZS EZ M2 M1 M0 1. Error buzzer function is
ページ4に含まれる内容の要旨
Setting the RAID Mode: 1. For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume. It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager. 2. Modify the RAID mode on the 5-port HPM-XU using DIP switch Recommended to be used on operating system without JMicron HW RAID Mana
ページ5に含まれる内容の要旨
RAID 0 Mode Clone Mode SW1 SW1 1 2 3 4 5 1 2 3 4 5 BZS EZ M2 M1 M0 BZS EZ M2 M1 M0 RAID 1& RAID 10 Mode Large Mode SW1 SW1 1 2 3 4 5 1 2 3 4 5 BZS EZ M2 M1 M0 BZS EZ M2 M1 M0 RAID 3 Mode Individual Drives Mode SW1 SW1 1 2 3 4 5 1 2 3 4 5 BZS EZ M2 M1 M0 BZS EZ M2 M1 M0 RAID 5 Mode SW1 1 2 3 4 5 BZS EZ M2
ページ6に含まれる内容の要旨
RAID Setting Notes: When 2 drives are RAID 1& RAID 10 Mode connected to the HPM-XU, and DIP switch is set to this setting, the 2 drives will be SW1 1 2 3 4 5 configured as a 2-drive RAID1 array. BZS EZ M2 M1 M0 When 4 drives are connected to the HPM-XU, the 4 drives will be configured as a 4-drive RAID10 array. Clone’s action is similar to Clone Mode RAID1. However, all of the hard drives will be mirrored. Clone mode is useful SW1 especially when users like
ページ7に含まれる内容の要旨
Notes on Spare Drives using the Easy RAID Setting (EZ) When EZ function is ENABLED, the auto-rebuilding to spare drive is automatic. The degraded RAID group will start rebuilding automatically by using the existing spare drive. * Spare drive can be either plugged after RAID building or a new drive can be plug as the spare drive when RAID rebuild is required. When will rebuild action start? • When the raid fails and EZ is enabled, the HPM-XU will automatically rebuild the RAID group using the spa