ページ1に含まれる内容の要旨
INSTALLATION
RK5000PS-3U/RK5000-3U
Rack Mount Chassis
For Fiber Optic Modules
C1972M-A (10/06)
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Description . . . . . . . . . . . . . . . . . . . . .
ページ4に含まれる内容の要旨
List of Illustrations 1 RK5000PS-3U Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 RK5000PS-3U Back View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3 RK5000-3U Front View . . . . . . . . . . . . . . . . . .
ページ5に含まれる内容の要旨
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the pola
ページ6に含まれる内容の要旨
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provid
ページ7に含まれる内容の要旨
Description The RK5000PS-3U rack mount chassis supports fiber optic modules. The chassis has 12 slots and an internal double-width power supply. You can insert up to 12 single-width modules or a combination of single-width and double-width modules into the slots. For redundancy, you can use the optional external power supply (EPS5000-120). It provides redundant power for up to two fully populated RK5000PS-3U chassis. You can mount the chassis, which is 3 rack units (RU) high, into an EIA-stan
ページ8に含まれる内容の要旨
FRONT VIEW (RK5000PS-3U) Rack Ears (2) Power Supply Module Slots (12) Alarm from Module LED Power Fail LED Pelco Badge Figure 1. RK5000PS-3U Front View BACK VIEW (RK5000PS-3U) Thumbscrews for Fastening Modules (12) External Connector for Redundant Power Supply Relay Output Connector with Screw Terminal Power Button Power Cord Connector Figure 2. RK5000PS-3U Back View 8 C1972M-A (10/06)
ページ9に含まれる内容の要旨
FRONT VIEW (RK5000-3U) Rack Ears (2) Module Slots (14) Figure 3. RK5000-3U Front View BACK VIEW (RK5000-3U) External Connector for Redundant Power Supply Thumbscrews for Fastening Modules (14) Figure 4. RK5000-3U Back View C1972M-A (10/06) 9
ページ10に含まれる内容の要旨
Installation PACKAGE CONTENTS RK5000PS-3U 1 Rack mount chassis 4 Screws and washers for rack mounting RK5000-3U 1 Rack mount chassis 4 Screws and washers for rack mounting MOUNTING A CHASSIS WARNING: To ensure adequate ventilation, 1 RU of space is required above and below the RK5000PS-3U. The procedure for mounting an RK5000PS-3U and an RK5000-3U into a rack is exactly the same. To mount a chassis, follow these steps and refer to Figure 5. 1. Insert the chassis into the rack. 2. Secure t
ページ11に含まれる内容の要旨
INSTALLING A MODULE You can install single-width or double-width modules into the empty slots on the RK5000PS-3U chassis and RK5000-3U chassis. To install a module, follow these steps and refer to Figure 6. 1. Insert the module into an empty slot of the chassis. 2. Secure the module by tightening the thumbscrew on the back of the chassis. Figure 6. Module Installation INSTALLING A BLANK MODULE You can use single-width or double-width blank modules to fill the empty module slots on the chassis.
ページ12に含まれる内容の要旨
Service REMOVING THE POWER BUS You must remove the power bus from the RK5000PS-3U if you want to use the power supplies that are provided with the Fiber modules. WARNING: Using the power supplies that are provided with the Fiber modules with the power bus on the RK5000PS-3U can cause damage to the unit. To remove the power bus, follow these steps and refer to Figure 8. 1. Turn off the power supply. 2. Remove the power supply. 3. Unscrew the five Phillips flat head screws. Figure 8. Power Bus
ページ13に含まれる内容の要旨
REPLACING AN INTERNAL POWER SUPPLY You can easily replace the internal power supply in the RK5000PS-3U in case of failure. The front of the power supply has two LEDs. The top LED turns red when there is an alarm condition from one of the modules. The bottom LED turns red when the power supply fails. To replace an internal power supply, follow these steps and refer to Figure 9. 1. Unplug the power cord. 2. Unscrew the two thumbscrews on the back of the chassis that hold the power supply. 3. Rem
ページ14に含まれる内容の要旨
Specifications RK5000PS-3U ELECTRICAL Input Voltage 100-240 VAC Input Current 1.0 A Output Voltage 12 VDC Output Current 10 A Fuse Rating 1.6 A Redundant Capability Yes with optional EPS5000-120 power supply MECHANICAL Number of Slots 12 for modules and 2 for power supply Module Orientation Vertical Rack Units 3 Construction Aluminum Finish Black GENERAL Operating Temperature 32° to 122°F (0° to 50°C) Operating Humidity 80% maximum relative humidity, noncondensing Storage Humidity 95% maximum r
ページ15に含まれる内容の要旨
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: If a warranty repair is required, the Dealer must contact Pelco at (800)þ289-910
ページ16に含まれる内容の要旨
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO9001 Australia Canada Finland France Italy Russia Singapore Spain Sweden The Netherlands United Arab Emirates United Kingdom United States | | | | | | | | | | | |