ページ1に含まれる内容の要旨
Dell™ PowerEdge™ 6800 Systems
Information Update
信息更新
Mise à jour des informations
Aktuelle Informationen
アップデート情報
설명서 갱신본
Actualización de información
www.dell.com | support.dell.com
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Dell™ PowerEdge™ 6800 Systems Information Update www.dell.com | support.dell.com
ページ4に含まれる内容の要旨
Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death. ____________________ Information in this document is subject to change without notice. © 2006 Dell Inc. All rights reserved. Reproduction in any manner whatsoever wi
ページ5に含まれる内容の要旨
Information Update This document provides information for your system on the following topics: Reconfiguring the system for regional power requirements Processor upgrades Adaptec SCSI Card 39160 expansion-card slot restrictions System start-up behavior Integrated NIC IPMI port functionality Remote Access Controller card interaction with integrated video System messages Environmental data sheets Removing and installing the cooling shroud Linux operating system information ® ®
ページ6に含まれる内容の要旨
Reconfiguring the System for Regional Power Requirements CAUTION: If you relocate a system operating in the 120–127 VAC or 200–240 VAC range to a different geographic area, ensure that jumper CB_TYPE matches the AC line voltage range of your new location. If the new power source is less than 120 VAC and you do not reconfigure jumper CB_TYPE for the lower voltage power source, damage to the system power cable or the system itself may occur. Table 1-1 lists countries where the AC line voltage
ページ7に含まれる内容の要旨
Figure 1-1. Power Configuration Jumper Location Processor Upgrades If you add one or more processors to your system, ensure that all processors have the same stepping value and the same cache size and technology. If you install processors with different speeds, they will operate at the speed of the slowest processor. You must install all voltage regulator modules (VRMs) included in the upgrade kit, in addition to the processors. See "Processors" in your Installation and Troubleshooting Guide
ページ8に含まれる内容の要旨
System Start-Up Behavior The following system behaviors during system start-up are normal and do not indicate a problem with the system: When AC power is applied to the system, if the System Setup program’s AC Power Recovery option is not set to allow the system to power up when AC power is applied, the cooling fans will spin-up briefly and then stop. (See your User’s Guide for information on the System Setup program.) It may take 30 seconds or longer for video to display after the system
ページ9に含まれる内容の要旨
Table 1-3. LCD Status Messages Line 1 Line 2 Causes Corrective Actions Message Message SYSTEM SYSTEM NAME SYSTEM ID is a unique name, This message is for information ID five characters or less, defined by only. the user. You can change the system ID SYSTEM NAME is a unique and name in the System Setup name, 16 characters or less, program. See your User's Guide defined by the user. for instructions. The system ID and name display under the following conditions: The system is powered on.
ページ10に含まれる内容の要旨
Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0119 TEMP PLANAR System board temperature is out See "Troubleshooting System of acceptable temperature range. Cooling Problems" in your Installation and Troubleshooting Guide. E0212 PROC VTT Processor VTT voltage is out See "Troubleshooting Power of acceptable voltage range. Supplies" in your Installation and Troubleshooting Guide. E0212 VOLT PG n System power supply is out of See "Troublesho
ページ11に含まれる内容の要旨
Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0276 VRM # PG The voltage of the specified VRM See "Troubleshooting the is out of acceptable range. Microprocessors" in your Installation and Troubleshooting Guide. If the problem still persists, see "Getting Help" in your Installation and Troubleshooting Guide. E0276 VCACHE # PG The voltage of the specified See "Troubleshooting the VCACHE is out of acceptable Microprocessors" in your rang
ページ12に含まれる内容の要旨
Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0780 PROC n PRESENCE Microprocessor is not installed Install a microprocessor in socket in socket n. n. See "Installing a Processor" in your Installation and Troubleshooting Guide. E07F0 PROC n IERR Faulty or improperly installed See "Troubleshooting the microprocessor. Microprocessors" in your Installation and Troubleshooting Guide. E07FA PROC n THERMTRIP Specified microprocessor is out See
ページ13に含まれる内容の要旨
Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0880 PS REDUNDANCY Power supply redundancy has Reinstall the power supply LOST been lost because a power supply to restore redundancy. has been removed from the system. E0D76 BP DRIVE n Faulty or improperly installed See "Troubleshooting SCSI Hard hard drive or RAID controller. Drives," "Troubleshooting a RAID Controller Card," and "Troubleshooting the Integrated RAID Controller" in your In
ページ14に含まれる内容の要旨
Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message EB10C ECC UNCORR ERR Uncorrectable ECC errors have See "Troubleshooting System occurred in system memory. The Memory" in your Installation ECC UNCORR ERR affected memory bank may be and Troubleshooting Guide. BANK # specified. EB113 I/O CHANNEL CHK System I/O channel check error See "Getting Help" in your has occurred. Installation and Troubleshooting Guide. EB113 PCI PARITY ERR PCI parity err
ページ15に含まれる内容の要旨
Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message EB113 CHIPSET ERR An error has occurred in the See "Troubleshooting the chipset. Microprocessors" in your Installation and Troubleshooting Guide. If the problem persists, see "Troubleshooting Expansion Cards" in your Installation and Troubleshooting Guide. If the problem still persists, see "Getting Help" in your Installation and Troubleshooting Guide. EFFF2 ROMB PRESENCE Integrated RAID
ページ16に含まれる内容の要旨
Removing and Installing the Cooling Shroud To remove the cooling shroud, grasp each end of the shroud and lift the shroud straight up from the system. To install the cooling shroud, slowly lower the shroud straight down into the system and then press down on the four icons (above the latches) until the shroud snaps into place. See Figure 1-2. Figure 1-2. Removing and Installing the Cooling Shroud icons (4) cooling shroud latches (4) 14 Information Update
ページ17に含まれる内容の要旨
Linux Operating System Information Booting Red Hat Enterprise Linux AS (Version 4) for Intel x86 With More than Eight Logical Processors A system running the Red Hat Enterprise Linux AS (version 4) for Intel x86 operating system will fail to boot if it is configured with more than eight logical processors. To work around this issue, pass the parameter apic=bigsmp to the kernel command line at system boot. A correction for this issue will be available in a future Red Hat Enterprise Linux Vers
ページ18に含まれる内容の要旨
Microsoft Windows 2000 Installation Installation of Microsoft Windows 2000 Server or Microsoft Windows 2000 Advance Server is not supported on PowerEdge 6800 systems featuring dual-core processors with L3 cache. NOTE: Installation of Microsoft Windows 2000 Server or Microsoft Windows 2000 Advanced Server is supported on PowerEdge 6800 systems featuring single-core processors (with or without L3 cache) and dual-core processors with L2 cache only. The processor type can be obtained by one of t
ページ19に含まれる内容の要旨
™ ™ Dell PowerEdge 6800系统 信息更新 www.dell.com | support.dell.com
ページ20に含まれる内容の要旨
注、注意和警告 注:注表示可以帮助您更好地使用计算机的重要信息。 注意:注意表示可能会损坏硬件或导致数据丢失,并告诉您如何避免此类问题。 警告:警告表示可能会导致财产损失、人身伤害甚至死亡。 ____________________ 本文件中的信息如有更改,恕不另行通知。 © 2006 Dell Inc.版权所有,翻印必究。 未经 Dell Inc. 书面许可,严禁以任何形式进行复制。 本文中使用的商标:Dell、DELL 徽标和 PowerEdge 是 Dell Inc. 商标; Intel 是 Intel Corporation 的注册商标; Microsoft 和 Windows 是 Microsoft Corporation 的注册商标,Windows Server 是 Microsoft Corporation 的商标; Red Hat 是 Red Hat Corporation 的注册商 标; SUSE 是 SUSE LINUX Products GmbH 的注册商标。 本文件中述及的其它商标和产品名称是指拥有相应商标和名称的公司或其制造的产品。Dell Inc.