INSTALLATION & OPERATION MANUAL FOR
Hotplates
MODEL MLS
VHP212 ML-135AHP-12
VHP424 ML-135AHP-24
VHP636 ML-135AHP-36
VHP848 ML-135AHP-48
www.vulcanhart.com
MODELS
MLS
AHP212 ML-135AHP-12
AHP424 ML-135AHP-24
AHP636 ML-135AHP-36
AHP848 ML-135AHP-48
www.wolfrange.com
AHP424
ITW Food Equipment Group, LLC RETAIN THIS MANUAL FOR FUTURE USE
3600 North Point Blvd.
Baltimore, MA 21222 FORM F-36955 (04-07)
ページ2に含まれる内容の要旨
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE
ページ3に含まれる内容の要旨
INSTALLATION, OPERATION AND CARE OF GAS COUNTERTOP HOTPLATE RANGE GENERAL Gas Countertop Hotplates are designed for commercial use only and feature fast, efficient gas heat. Each burner is controlled by an adjustable gas valve. Cast grates and burners are easily removed for cleaning when cool. # of BTU/hr Input Rating BTU/hr Input Rating Model Burners Standard & Step-Up Half Hot-Top AHP212 / VHP212 2 60,000 45,000 (30,000 + 15,000) AHP424 / VHP424 4 120,000 90,000 (60,000 + 30,0
ページ4に含まれる内容の要旨
INSTALLATION CODES AND STANDARDS The hotplate must be installed in accordance with: In the United States of America: 1. State and local codes. 2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park
ページ5に含まれる内容の要旨
GAS CONNECTION The data plate on the right side, in the upper front corner of the appliance indicates the type of gas your unit is equipped to burn. DO NOT connect to any other gas type. CAUTION: All gas supply connections and any pipe joint compound must be resistant to the action of propane. Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting the line to the unit. Codes require that a gas shut-off valve be installed in the gas line ahead of the
ページ6に含まれる内容の要旨
OPERATION WARNING: THE HOTPLATE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING, OR SERVICING THE APPLIANCE. LIGHTING INSTRUCTIONS 1. Turn gas shutoff valve and burner valve to the OFF position and wait 5 minutes. 2. Turn gas shutoff valve ON. Light the pilot adjacent to each main burner. Adjust the pilot valve screw until the pilot flame has a slight yellow tip. 3. After the pilot has been established, turn the burner valve to the ON position. The burner flames may be ad