ページ1に含まれる内容の要旨
™
For Models:
BR36
BR42
BC36
BC42
BR/BC Series Woodburning Fireplace
Homeowner's Installation and Operating Manual
WF553
BR/BC36
1 1/10/97
For use in U.S./Canada
Underwriter's Laboratories
Report No. MH6018
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
DO NOT DISCARD THIS MANUAL: Retain for future use.
7412944 6/05 Rev. 16
ページ2に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Burn only solid wood fuel or gas logs. Description Do not install a solid fuel burning insert or other The BR/BC Series fireplaces are solid fuel, woodburning products not specified for use with
ページ3に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series BR36 Series Woodburning Fireplace ��" (559mm) Rough Opening Depth 11" Dia. 45���" (1162mm) ����" (279mm) ���" (13mm) ����� " (187mm) * (521mm) 8" Dia. (203mm) 20" Recessed (508mm) ���" Nailing Flange Rough Opening Width 41" (1041mm) Rough Opening Height ���" ����" (191mm) Outside 40���" Air (1035mm) 36 ���" � ��� �" Gas Line (930mm) � � � �" (502mm) 36" Access (191mm) �� " (914mm) Gas Line (533mm) Access ����� " (372mm) ����" (167mm) � � � �" 3" (76mm) 4
ページ4に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series BR42 Series Woodburning Fireplace ��" (711mm) Rough Opening Depth 11" Dia. 49" (1245mm) ����" (279mm) ����� " * (187mm) ���" (13mm) (521mm) 8" Dia. 20" (203mm) (508mm) ���" Recessed Nailing Flange Rough Opening Width 47" (1194mm) Rough Opening Height ���" ����" (191mm) 40���" Outside 36���" (1035mm) Air � ��� �" (930mm) Gas Line ����" 42" (502mm) Access (191mm) (1067mm) �� " Gas Line (533mm) Access ����� " (372mm) ����" (197mm) ����" 3" 46" (1168mm) (241mm
ページ5に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Front Width Back Width Depth A B C B BR/BC36 33 ¹⁄₄" 19 ⁵⁄₈" 15 ¹⁄₄" (845 mm) (499 mm) (387 mm) BR/BC42 39 ¹⁄₄" 25 ⁵⁄₈" 15 ¹⁄₄" C (997 mm) (651 mm) (387 mm) FP1531 FP1531 Fig. 4a Hearth dimensions. hearth dimensions 9/04 djt Chase Installation Insulation methods shown are optional Termination Cap for cold climate, not a requirement for unit operation. Storm Collar Pan Flashing Batt Insulation (cut our around firestop) Draftstop Firestop Ceiling L
ページ6に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION FP282 30˚ ELBOW 30˚ Elbow Offsets FP282 RETURN ELBOW MBUF B G A 5/26/96 1' Offset 1 ¹⁄₂' 3' 4' Rise G 30˚ 0 0 0 0 0 3" 11" OFFSET D 1 0 0 0 0 8 ¹⁄₄" 20" ELBOW E RISE 0 1 0 0 0 11 ¹⁄₄" 25 ¹⁄₄" 6 FT. 2 0 0 0 0 13 ¹⁄₂" 29 ¹⁄₄" SKCS8 30˚ C 1 1 0 0 0 16 ¹⁄₂" 34 ¹⁄₄" SUPPORT RETURN H ELBOW 0 0 1 0 0 20 ¹⁄₄" 40 ³⁄₄" OFFSET
ページ7に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Planning Information Preplanning an installation is very important to ensure The Ten Foot Rule safety and to save time and money. An installer must Major U.S. building codes specify a minimum chimney predetermine where a fireplace will be set and how the height above the roof top. The “Ten Foot Rule” is a fire chimney system will be run. safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the Mountin
ページ8に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Chimney Supports Installation The chimney system is supported by the fireplace for Insulating Fireplace Enclosure vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical for Cold Climates height exceeds 30' (9m) with SK8 chimneys or 20' If you live in a cold climate, it is not required but (6m) with 3-wall chimneys. Locate chimney supports highly recommended that you insulate fireplace at ceiling holes
ページ9に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Framing Option For Circulating Models Only — Framing can be constructed before or after the fire- EB1 (Receptacle) Hook-Up: place is set in place, however, most installers build the • Wiring should be installed by a certified frame before setting the fireplace. electrician. Frame fireplace with 2 x 4 lumber or heavier materials. • Turn off circuit breaker before wiring models. Refer to framing dimensions in Figures 1, 2, 3 or 4 for Once fireplace is secured,
ページ10に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Determine offset distance of your chimney arrangement Straight-Up Chimney Installation from centerline of fireplace to centerline of chimney To mark the centerline of the flue, put the fireplace where it is to pass through ceiling. in final position and measure out from the wall: 8 ¹⁄₄" Locate center point of the chimney on ceiling as though (210mm) a straight up chimney arrangement is to be used. Mea- sure your offset dimension from straight up chimney Mark a
ページ11に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series The following table gives firestop spacer model num- Installing Outside Air Kit bers: An outside air kit is installed in all BR/BC Series Fire- Angle of Chimney at Ceiling places. If desired, or if local codes mandate the use of Size of Chimney Vertical 30° an air kit, then an AK-MST is required to complete the 8" Flue SKFS2A SKFS6A installation (from air kit to the outdoors). If the outside "SK" Series 14 ¹⁄₂" x 14 ¹⁄₂" 14 ¹⁄₂" x 25 ¹⁄₂" air kit is to be
ページ12に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Installing the Chimney System Pipe Section Start by attaching the first chimney section to the collar Pipe Rim on top of the fireplace. Hem Install the pipe as pictured in Figure 16. When you Lance get a good lock, you will hear the pipe clearly snap Pipe Rim together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted. When installi
ページ13に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Firestop spacers are not available for nor are they re- quired on vertical walls. DO NOT put any sealant around the area where the Attic outer pipe slides through the firestop spacer. If you Insulation Shield seal this area, it may cause a fire hazard. Nails (4 required) Canadian Requirements for Insulation Shield In Canada, an attic insulation shield is required to pre- vent attic insulation from contacting the chimney sec- Attic Joist tion. Framing dime
ページ14に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Install Remainder of Chimney Sections Air Space Clearances Since you have already preplanned the height of your Combustible framing material MUST NOT termination according to the Ten Foot Rule, continue to penetrate AIR SPACE (shaded areas). install pipe to the predetermined height. Check the chimney top installation instructions for details on how high above the roof top the chimney sec- tions (all pipes) should extend. 1 ¹⁄₂" (SK8) Installing Top Housing 2
ページ15に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Mantel Clearance - Mantel Clearance - Radiant Model - No Mantel Clearance - Radiant Circulating Model Noncombustible Facing Material Model - with Noncombustible Facing Material Combustible Combustible Combustible Mantel and Mantel and Mantel and 12" 12" Trim 12" Trim Trim (305mm) (305mm) (305mm) Finished Finished Wall Finished Wall Max. Max. Max. Wall 1���" 1 ���" 1 ���" Header Header Header (38mm) (38mm) (38mm) 12" 12" 12" Standoff Standoff S
ページ16に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Side Wall Protection Hearth Installation Adjacent combustible side walls that are within mini- A hearth extension is required to protect a combustible mum dimensions shown in Figure 23 of the fireplace floor in front of the fireplace. Refer to Figure 23 for mini- opening must be protected with CFM Corporation Wall mum dimensions and mounting detail. Shield Model SP40 or a specifically built wall shield NOTE: Hearth Extension must not cover the air described in
ページ17に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series WARNING: HEARTH EXTENSION MUST BE IN- STALLED IN ACCORDANCE WITH FIGURE 23 AND Wall Covering MUST NOT COVER THE BOTTOM FRONT OPENING Noncombustible 2x4" HEADER - OF THE CIRCULATING MODEL. Decorative Do not notch at Facing standoffs. Alternate noncombustible materials may be used pro- viding the (total) thermal resistance (Rt value) of the al- Seal all cracks ternate material employed is greater than or equal to R between fireplace = 1.09 Thermal resista
ページ18に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Installing Line For Gas Log Fireplace Top View Hole in Outer Casing CFM Specialty Home Products fireplaces are designed to accept a 1/2 inch gas line for installation of an ap- proved gas appliance. (CFM Specialty Home Products 1" Supply Line Min. manufactures a wide variety of gas logs for use in CFM Gas Line Tube Specialty Home Products fireplaces.) Be sure to have the appliance installed in accordance Ceramic Repack Insulation Knockout with building codes
ページ19に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series 1 10 2 b 4 c 6 d 3 a 5 8 9 12 7 11 13 944 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, with out notice. BR/BC SERIES For units: FA30C1, FA30C0, FA30R1, FA30R0, GA30C1, GA30C0, GA30R1, GA30R0, FA40C1, FA40C0, FA40R1, FA40R0, GA40C1, GA40C0, GA40R1, GA40R0 Item/Model Number BR/BC36 BR/BC42 944 1. Damper Blade Weld Assembly RP199 RP199 BR/BC parts 2.
ページ20に含まれる内容の要旨
Majestic Fireplaces® BR/BC Series Accessories The following accessories for this appliance are available from your local Majestic Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Specialty Home Products, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be oper- ated only with CFM Specialty Home Prod