ページ1に含まれる内容の要旨
®
VENT-FREE PROPANE GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Model: VGP30B and VP2000BB
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone
ページ2に含まれる内容の要旨
SECTION PAGE CONTENTS Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ................................................................................... 4 Unpacking...................................................................................... 4 Product Features ............................................................................
ページ3に含まれる内容の要旨
SAFETY WARNINGS Continued WARNING ICON G 001 INFORMATION WARNING: Any change to this heater or its controls can be dangerous. Continued 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 3. If you smell gas • Shut off gas supply • Do not try to light any appliance • Do not touch any electrical switch; do not use any phone in your building • Immediately call your gas suppl
ページ4に含まれる内容の要旨
Ignitor Button Control Knob PRODUCT IDENTIFICATION Grill Guard Heat Shield (VGP30B) or Glass Panel (VP2000BB) Front Panel Heater Cabinet Figure 1 - Vent-Free Propane Gas Heater Install and use heater with care. Follow all local codes. In the absence of local LOCAL CODES codes, use the latest edition of National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc
ページ5に含まれる内容の要旨
FRESH AIR WARNING WARNING ICON G 001 FOR This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to COMBUSTION insure proper fresh air for this and other fuel-burning appliances in your home. AND VENTILATION Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to
ページ6に含まれる内容の要旨
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION FRESH AIR Determining if You Have a Confined or Unconfined Space FOR Use this worksheet to determine if you have a confined or unconfined space. COMBUSTION Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. AND 1. Determine the volume of the space (length x width x height). VENTILATION Length x Width x Height = ___________________ cu. ft. (volume of sp
ページ7に含まれる内容の要旨
VENTILATION AIR FRESH AIR Ventilation Air From Inside Building FOR This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the COMBUSTION ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and AND 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). VENTILATION WARNING WARNING ICON G 001 Continued Rework wor
ページ8に含まれる内容の要旨
VENTILATION AIR (Continued) FRESH AIR Ventilation Air From Outdoors FOR Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these COMBUSTION items directly to the outdoors or spaces open to the outdoors. These spaces include attics AND and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size o
ページ9に含まれる内容の要旨
INSTALLING NOTICE TO WALL A qualified service person must install heater. Follow all local codes. CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have the items listed below. • external regulator (supplied by • ground joint union installer, see page 14) • test gauge connection * (see • piping (check local codes) Figure 13, page 15)
ページ10に含まれる内容の要旨
INSTALLING CAUTION WARNING ICON G 001 TO WALL If you install the heater in a home garage • heater pilot and burner must be at least 18 inches above floor Continued • locate heater where moving vehicle will not hit it For convenience and efficiency, install heater • where there is easy access for operation, inspection, and service • where strong wind gusts from an open door or garage door can not blow directly into heater. An optional fan kit is available from your dealer. See Accessories, page
ページ11に含まれる内容の要旨
INSTALLING HEATER TO WALL INSTALLING Mounting Bracket TO WALL The mounting bracket is located on back panel of heater. It has been taped there for Continued shipping. Remove mounting bracket from back panel. Mounting Bracket Figure 5 - Mounting Bracket Location Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then down. 4. Remove c
ページ12に含まれる内容の要旨
Marking Screw Locations INSTALLING 1. Tape mounting bracket to wall where heater will be located. Make sure mount- TO WALL ing bracket is level. Continued WARNING WARNING ICON G 001 Maintain minimum clearances shown in Figure 7. If you can, provide greater clearances from floor and joining wall. 2. Mark screw locations on wall (see Figure 7). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall.
ページ13に含まれる内容の要旨
4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to INSTALLING “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. TO WALL Continued Figure 9 - Popping Open Anchor Wings For Thin Walls 5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is fi
ページ14に含まれる内容の要旨
CONNECTING NOTICE A qualified service person must connect heater to gas supply. TO GAS Follow all local codes. SUPPLY CAUTION WARNING ICON G 001 Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches
ページ15に含まれる内容の要旨
IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping CONNECTING and/or fittings. Note: Burner bracket TO GAS not shown for clarity Pressure SUPPLY Regulator Continued 1/2" NPT Pipe Nipple Heater Ground Joint Cabinet Union Tee Joint Test Reducer Manual Bushing to Gauge Shutoff 1/8" NPT Connection * Valve * 1/8" NPT From Plug Tap External Regulator (11" W.C. to 14" W.C. Pressure) Tee Joint Sediment Pipe Trap 3" Minimum Nipple Cap Figure 13 - Gas Connection * An A.G.A.
ページ16に含まれる内容の要旨
3. Pressurize supply piping system by either using compressed air or CHECKING opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and GAS water to gas joints. Bubbles forming show a leak. CONNECTIONS 5. Correct all leaks at once. Continued Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 14). 2. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 3.
ページ17に含まれる内容の要旨
OPERATING FOR YOUR SAFETY READ BEFORE LIGHTING HEATER WARNING WARNING ICON G 001 If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the
ページ18に含まれる内容の要旨
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including OPERATING near the floor. If you smell gas, STOP! Follow “B” in the safety information HEATER at the top of page 17. If you don’t smell gas, go to the next step. Continued C-clockwise 5. Press in control knob and turn counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 16, page 17). Note: You may be running this heater for the first time after hooking up to gas supply.
ページ19に含まれる内容の要旨
OPERATING TO TURN OFF GAS TO APPLIANCE Shutting Off Heater HEATER Clockwise 1. Turn control knob clockwise to the PILOT position. Continued 2. Press in control knob and turn clockwise Clockwise to the OFF position. 3. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Remove front panel (see Figure 6, page 11). 2. Follow steps 1 through
ページ20に含まれる内容の要旨
If pilot flame pattern is incorrect, as shown in Figure 19 INSPECTING • turn heater off (see To Turn Off Gas to Appliance, page 19) BURNER • see Troubleshooting, pages 21 through 24 Continued BURNER FLAME PATTERN Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the heat shield height. WARNING ICON G 001 WARNING If yellow tipping occurs, y