ページ1に含まれる内容の要旨
FURN-PRC001-EN
Upflow/Horizontal Right
or Upflow/Horizontal Left
Induced Draft Gas Furnace
XR 80
TUD040,060,080,100,120,140C
Single-Stage Fan Assisted
Combustion System
PUB. NO. 22-1640-06-0702 (EN)
ページ2に含まれる内容の要旨
General Features Natural Gas Models Air Delivery Central Heating furnace designs are The 4-speed, direct drive blower motor, certified by the American and Canadian has sufficient airflow for most heating and Gas Associations for both natural and cooling requirements, will switch from L.P. gas. Limit setting and rating data heating to cooling speeds on demand were established and approved under from room thermostat. The blower door standard rating conditions using American safety switch will pre
ページ3に含まれる内容の要旨
Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6 TUD040C924K 6 TUD040C930K 6 TUD060C924K 6 TUD060C936K 6 TUD080C924K 7 TUD080C936K 7 TUD080C948K 7 TUD080C960K 7 TUD100C936K 8 TUD100C945K 8 TUD100C948K 8 TUD100C960K 8 TUD100C972K 9 TUD120C954K 9 TUD120C960K 9 TUD140C960K 9 Performance Data 10 Field Wiring 12 Twinning Field Wiring 13 Dimensions 14 Electrical Data 15 22-1640-06-0702 (EN) 3
ページ4に含まれる内容の要旨
Features and Benefits XR 80 Upflow/Horizontal Right Or Left Standard Equipment • Power supply 115/1/60 Cleanable high velocity filters Multi-port In-shot burners Standard filter sizes Integrated solid state control with Single wire twinning self diagnostics Selectable cooling fan off delay Silicon Nitride hot surface igniter with Left-right gas connection adaptive heat up Optional L.P. conversion kit Complete front service access Common vent capability Heavy guage alumini
ページ5に含まれる内容の要旨
Features and Benefits Optional Equipment Thermostat .............................................................................................................................................................. BAYSTAT388 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................ AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ........................................................
ページ6に含まれる内容の要旨
General Data Product Specifications 1 MODEL TUD040C924K TUD040C930K TUD060C924K TUD060C936K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 40,000 40,000 60,000 60,000 Capacity BTUH (ICS) 3 32,000 32,000 47,000 47,000 AFUE 80.0 80.0 80.0 80.0 Temp. rise (Min.-Max.) °F. 30 - 60 30 - 60 35 - 65 30 - 60 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter - Width (In.) 10 x 6 10 x 6 10 x 6 10 x 7 No. Used 1 1 1 1 Speeds (No.) 4 4 4 4 CFM vs
ページ7に含まれる内容の要旨
General Data Product Specifications 1 MODEL TUD080C924K TUD080C936K TUD080C948K TUD080C960K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 80,000 80,000 80,000 80,000 Capacity BTUH (ICS) 3 64,000 63,000 64,000 64,000 AFUE 80.0 80.0 80.0 80.0 Temp. rise (Min.-Max.) °F. 50 - 80 30 - 60 30 - 60 25 - 55 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter - Width (In.) 9 x 7 10 x 7 10 x 8 11 x 10 No. Used 1 1 1 1 Speeds (No.) 4 4 4 4 CFM vs
ページ8に含まれる内容の要旨
General Data Product Specifications 1 MODEL TUD100C936K TUD100C945K TUD100C948K TUD100C960K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 100,000 100,000 100,000 100,000 Capacity BTUH (ICS) 3 79,000 79,000 79,000 79,000 AFUE 80.0 80.0 80.0 80.0 Temp. rise (Min.-Max.) °F. 40 - 70 35 - 65 35 - 65 30 - 60 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter - Width (In.) 10 x 7 10 x 8 10 x 8 11 x 10 No. Used 1 1 1 1 Speeds (No.) 4 4 4 4 C
ページ9に含まれる内容の要旨
General Data Product Specifications 1 MODEL TUD100C972K TUD120C954K TUD120C960K TUD140C960K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 100,000 120,000 120,000 140,000 Capacity BTUH (ICS) 3 80000 96,000 96,000 111,000 AFUE 80.0 80.0 80.0 80.0 Temp. rise (Min.-Max.) °F. 30 - 60 35 - 65 30 - 60 40 - 70 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter - Width (In.) 11 x 10 11 x 10 11 x 10 11 x 10 No. Used 1 1 1 1 Speeds (No.) 4 4 4
ページ10に含まれる内容の要旨
Performance Data FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 4 - HIGH - Black 1018 1004 982 950 910 860 802 763 660 3 - MED.-HIGH - Blue 847 832 809 779 742 697 644 585 517 TUD040C924K 2 - MED.-LOW - Yellow 716 701 678 648 610 585 512 452 384 1 - LOW - Red 617 599 575 544 507 463 413 357 294 4 - HIGH - Black 1307 1262 1211 1164 1092 1023 949 869 783 3 - MED.-HIGH - Blue 1172 1140 1100 1053 996 937 867 791 707 TUD040C930K 2 -
ページ11に含まれる内容の要旨
Performance Data FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUD100C972K 4 - HIGH - Black 2484 2458 2432 2387 2342 2275 2208 2125 2041 BOTTOM AND 3 - MED.-HIGH - Blue SEE LEFT SIDE 2 - MED.-LOW - Yellow NOTE RETURN 1 - LOW - Red 1 4 - HIGH - Black 2447 2401 2356 2303 2249 2173 2097 1994 1892 3 - MED.-HIGH - Blue 2097 2088 2079 2053 2028 1970 1912 1831 1750 TUD100C972K 2 - MED.-LOW - Yellow 1753 1750 1748 1732 1716 1690 1665 1
ページ12に含まれる内容の要旨
Field Wiring Field Wiring Diagram For Heating Only From Dwg. 21B341437 Rev. 1 Field Wiring Diagram For Single Stage Heating/Cooling (Outdoor Section Without Transformer) From Dwg. 21B341436 Rev. 1 12 22-1640-06-0702 (EN)
ページ13に含まれる内容の要旨
Twinning Field Wiring From Dwg. 21B341422 Rev. 1 From Dwg. 21B341423 Rev. 1 22-1640-06-0702 (EN) 13
ページ14に含まれる内容の要旨
14 22-1640-06-0702 (EN) TUD-C Outline Drawing (All dimensions are in inches) From Dwg. 21C341699 Rev. 1
ページ15に含まれる内容の要旨
Electrical Data Schematic Diagrams for Gas Furnaces From Dwg. 21D341704 Rev. 1 22-1640-06-0702 (EN) 15
ページ16に含まれる内容の要旨
Literature Order Number FURN-PRC001-EN P.I. File Number — Supersedes TUD-D-1 3/98 Stocking Location PI Louisville & Webb/Mason-Houston 7/02 Trane A business of Trane has a policy of continuous product and product data improvement and it reserves the right to change American Standard Companies www.trane.com design and specifications without notice.