ページ1に含まれる内容の要旨
ページ2に含まれる内容の要旨
WATTS NO. OF RECEPTACLE CIRCUIT MODEL NO. VOLTS PHASE HZ AMPS POWER CORD KW HEATERS NEMA NO. BREAKER AMPS FTC-3-N, FTC-3.5-N 120 1 60 1.75 1 15 5-15R 5-15P [2 WIRES+GND] 15A FTC-5-N, FTC-5-N, FTC-10-N 240 1 60 2.80 1 12.5 6-20R 6-20P [2 WIRES+GND] 20A FTC-10-N 240 1 60 5.60 2 25 6-30R 6-30P [2WIRES+GND] 30A ELECTRICAL SPECFICATIONS * Export 220 Volts, 2.40 KW OPERATING ENVIRONMENTAL TEMPERATURE: Do not store unit in temperatures of 32° F or below wit
ページ3に含まれる内容の要旨
Note: In areas with extremely hard water, a Water Softener must be installed to prevent a malfunctioning of the equipment due to high lime and mineral buildup. Not doing so it will void the warranty. COMPLIANCES! This equipment to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and of the Food and Drug Administration (FDA.) INITIAL SET-UP, 1 .Make sure unit is disconnected from power source. 2..Re
ページ4に含まれる内容の要旨
Tea Brewing Instructions CAUTION: Operate with care. Tea Brewer dispenses HOT WATER and HOT TEA that can cause serious burns. 1. Start each brew cycle with a clean brew funnel and a clean empty tea dispenser. 2. Place a tea bag into the funnel and slide the funnel into the funnel rails until it stops. 3. When the Green Brew Switch Light comes on, press and release the Brew Button. NOTE: This tea brewer will not brew until the pre-set brew temperature (197-203°
ページ5に含まれる内容の要旨
5
ページ6に含まれる内容の要旨
6
ページ7に含まれる内容の要旨
7
ページ8に含まれる内容の要旨
SANITIZING: All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70° - 90°F). Soak all parts for a minimum of 3 min. in the sanitizing solution. Note: Always start with an unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span. Let all sanitized parts dr
ページ9に含まれる内容の要旨
TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1 a) Heater Switch OFF. a) Turn Heater Switch ON. Brewed Cold Tea. b) Run out of hot water b) Allow time for water in tank to heat after filling. c) Thermostat is OFF. c
ページ10に含まれる内容の要旨
10
ページ11に含まれる内容の要旨
11
ページ12に含まれる内容の要旨
12
ページ13に含まれる内容の要旨
13
ページ14に含まれる内容の要旨
14
ページ15に含まれる内容の要旨
15
ページ16に含まれる内容の要旨
ページ17に含まれる内容の要旨