ページ1に含まれる内容の要旨
VPR TC
VPR APS
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION OF CANADA
280 INDUSTRIAL PARKWAY SOUTH,
AURORA, ONTARIO, L4G 3T9
PHONE: (905) 841-2866 FAX: (905) 841-2775
39064.7000A 05/09 ©2006 Bunn-O-Matic Corporation www.bunn.com
ページ2に含まれる内容の要旨
INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It is only for indoor use on a sturdy counter or shelf. BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corporation of Canada (“Bunn”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital) - 1 year parts and 1 year labour. 2) All oth
ページ3に含まれる内容の要旨
USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. ! WARNING ! AVERTISSEMENT • FILL WATER TANK BEFORE PLUGGING IN UNIT OR • REMPLIR LE RÉSERVOIR D'EAU AVANT DE BRANCHER WARNING / AVERTISSEMENT ENERGIZING THE THERMOSTAT. L'APPAREIL OU DE METTRE LE THERMOSTAT SOUS TENSION. • DO NOT OVERLOAD CIRCUIT. • NE PAS SURCHARGER LE CIRCUIT. DISCARD DECANTER
ページ4に含まれる内容の要旨
ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. The brewer has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. INITIAL SET-UP CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. 2. Place an empty dispenser under the funnel. 3. Pou
ページ5に含まれる内容の要旨
TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be per formed only by qualified ser vice person- nel. • This brewer is heated at all times. Keep away from combustibles. WARNING – • Exer cise extrem
ページ6に含まれる内容の要旨
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Dripping from sprayhead 1. Lime Build-up Inspect the tank assembly for CAUTION - Tank and tank com- excessive lime deposits. Delime ponents should be delimed as required. regularly depending on local water conditions. Excessive min- eral build-up on stainless steel surfaces can initiate corrosive reactions resulting in serious leaks. Beverage overflows dispenser 1. Dispenser The dispenser must be com- pletely empty before starting a br
ページ7に含まれる内容の要旨
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY ® Dry coffee grounds remain in the 1. Funnel Loading The BUNN paper filter must be funnel centered in the funnel and the bed of grounds leveled by gently shaking. Brewer is making unusal noises 1. Tank Heater Remove and clean lime off the tank heater. See page 10 39064 042806 Page 7
ページ8に含まれる内容の要旨
The tank inlet fitting secures the fill basin to the SERVICE tank lid. This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service personnel. The brewer should be disconnected from the power source when servicing, ex
ページ9に含まれる内容の要旨
SERVICE (cont.) Removal and Replacement: 1. Remove wires from control thermostat leads or terminals. Location: 2. Remove the thermostat capillary bulb by firmly The control thermostat is located inside the hood pulling-up on the capillary at the tank lid. This on the left end of the mounting bracket. will disengage the grommet from the tank lid. Test Procedures: 1. Disconnect the brewer from the power source. 2. Locate the black wire on the control thermo- stat. 3. Check voltage acros
ページ10に含まれる内容の要旨
SERVICE (cont.) Removal and Replacement: 1. Remove all wires from limit thermostat termi- LIMIT THERMOSTAT nals. 2. Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat. 3. Carefully slide the new limit thermostat into the retaining clip. 4. Refer to Fig. 6 when reconnecting the wires. TANK HEATER P2414 FIG. 5 LIMIT THERMOSTAT Location: The limit thermostat is located inside the hood on the right side of the tank lid. Test Procedures: 1. Disconne
ページ11に含まれる内容の要旨
SERVICE (cont.) If continuity is present as described, reconnect the wires, the tank heater is operating properly. If continuity is not present as described, replace the tank heater. NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath. Removal and Replacement: 1. Remove the tank inlet fitting securing the fill basin to the tank lid, remove fill basin and tank inlet gasket. Set all three parts aside for reas- sembly. 2. Disconnect the black w
ページ12に含まれる内容の要旨
SCHEMATIC WIRING DIAGRAM VPR, VPR TC & VPR APS L1 N GREEN LIMIT SW. & THERMOSTAT THERMOSTAT BLK BLU/BLK WHI BLK TANK HEATER WHI WHI "KEEP WARM" HEATER MODEL VPR ONLY ON/OFF SWITCH WHI LOWER WARMER BLK WHI/RED WHI ON/OFF SWITCH WHI UPPER WARMER BLK VIO WHI 120 VOLTS A C 2 WIRE SINGLE PHASE 60 HZ 33769.0000C 03/06 © 2001 BUNN-O-MATIC CORPORATION Thermal Transfer Stock W/Tape Over-Laminate Black Ink Finished Size: 4" x 4" ~81% Reduction 39064 042806 Page 12