ページ1に含まれる内容の要旨
672
OWNERS MANUAL
for
SS2 - SERIES
DUAL SATELLITE
COFFEE BREWERS
with
ELECTRONIC
PROGRAMMABLE
CONTROL
and
INTERNALLY HEATED
SATELLITE SERVERS
MODELS:
9520 9520FB
9521 9521FB
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 9520 Dual Satellite Brewer
with optional
3901 Drip Tray
PRINTED IN UNITED STATES OF AMERICA
p/n 74345 Rev. J ECN-12887
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
TABLE OF CONTENTS Thank You for purchasing this WARRANTY STATEMENT xi Bloomfield Industries appliance. SPECIFICATIONS 1 Proper installation, professional FEATURES & OPERATING CONTROLS 2 operation and consistent PRECAUTIONS & GENERAL INFORMATION 4 maintenance of this appliance will AGENCY APPROVAL INFORMATION
ページ4に含まれる内容の要旨
ページ5に含まれる内容の要旨
FEATURES AND OPERATING CONTROLS (continued) Brewer Adjustable Legs Allows brewer to be leveled. Also allow clearance for cleaning underneath brewer. Brewing Controls Start or stop brew and select brew volume. Right and left section are independent. Also, used to program brewer in programming mode. Connector Connects to satellite. Allows satellite heater to be energized. Allows brewer to sense that a satellite is in place. Digital Readout Di
ページ6に含まれる内容の要旨
672 74345 Owners Manual Dual Satellite 9520/9521 GENERAL INFORMATION AND PRECAUTIONS This appliance is intended for use in commercial establishments WARNING: only. Electric Shock hazard This appliance is intended to brew hot beverage, specifically coffee, for human consumption. No other use is recommended or authorized All servicing requiring by the manufacturer or its agents. access to non-insulated electrical components Operators of this appliance must be familiar with th
ページ7に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INSTALL LEGS NOTE: To enable the installer to make The brewer is provided with adjustable legs and rubber feet. Be a quality installation and to sure the legs are securely screwed into the base of the brewer, and minimize installation time, these that the rubber feet are properly installed. tests and suggestions should be completed before the actual LEVEL THE UNIT installation is begun. The adjustable legs allow the brewer to be leveled. Set the b
ページ8に含まれる内容の要旨
672 74345 Owners Manual Dual Satellite 9520/9521 INSTALLATION INSTRUCTIONS (continued) IMPORTANT: INITIAL SET-UP INSTRUCTIONS Initial set-up must be performed by a qualified installer or Plumber’s and Electrician’s installation procedures must be qualified service technician. completed before proceeding with the set-up. Improper set-up will damage the brewer and void the warranty. Be sure all electrical connections are secure, and that all plumbing connections are secure and l
ページ9に含まれる内容の要旨
OPERATING INSTRUCTIONS Fig. 3 Control Panel GETTING STARTED Check the brewer and satellites: Check that the brewer is clean and the drip tray (if used) is empty. Check that the satellites are empty and clean with lids properly installed. Check the spray heads: Remove the brew chambers. Check the spray heads. Verify that the spray disks are clean and properly installed. Verify that the gaskets are prop
ページ10に含まれる内容の要旨
ページ11に含まれる内容の要旨
ページ12に含まれる内容の要旨
672 74345 Owners Manual Dual Satellite 9520/9521 CLE CLEA ANIN NING G INS INST TR RU UC CT TIIO ONS NS CAUTION: PROCEDURE: Clean Coffee Brewer Burn Hazard PRECAUTIONS: Press POWER key to OFF. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Hot coffee will cause Bristle Brush serious skin
ページ13に含まれる内容の要旨
CLEANING INSTRUCTIONS (continued) CAUTION: PROCEDURE: Clean Satellite Burn Hazard PRECAUTIONS: Drain Satellite before Cleaning Brewing and serving FREQUENCY: Twice Weekly temperatures of coffee are extremely hot. TOOLS: Sight Glass Brush, Sanitizer Soft Clean Cloth, Bucket Hot coffee will cause serious skin burns. 1. Remove and drain satellites. WARNING: 2. Place 1 packet of Sanitizer into 2-1/2 g
ページ14に含まれる内容の要旨
ページ15に含まれる内容の要旨
ページ16に含まれる内容の要旨
ページ17に含まれる内容の要旨
PROGRAMMING (continued) Brew Volume 7. Automatic Start-Up in Previous Mode: The 1st key is the Standard If the Satellite Brewer automatic timer is OFF (the factory setting) and power is disconnected, the brewer will start up Brew Volume. When a brew volume other when power is restored, in the mode it had been in prior to than standard brew volume is the power disconnection. If the Satellite Brewer has the selected, the Brewer will timer setti
ページ18に含まれる内容の要旨
672 74345 Owners Manual Dual Satellite 9520/9521 PROGRAMMING (continued) The factory programming has 12. After Hours™: The After Hours™ can be programmed to the After Hours™ mode turned come on from 1 to 6 hours after the last brew. When the OFF. Brewer goes into the After Hours™ mode, the water in the tank will be allowed to drop from the normal brewing While in the After Hours mode, temperature and will reheat less frequently – this feature the POW
ページ19に含まれる内容の要旨
TROUBLESHOOTING SUGGESTIONS DESCRIPTION OF PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY No lights or heat Unit not plugged in or circuit Restore electric power breaker tripped Power switch OFF Turn power switch ON No heat Hi-limit safety tripped Allow brewer to cool, verify water level, reset hi-limit Brewer overflows Water level probe corroded Clean water level probe Poor ground connection Verify ground connection Dirt in inlet valve or valve Replace inlet valve damaged Brew va
ページ20に含まれる内容の要旨
672 74345 Owners Manual Dual Satellite 9520/9521 SERVICING INSTRUCTIONS CAUTION - PROCEDURE: Delime the Water Tank CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals are caustic. Wear appropriate protective FREQUENCY: As required (Brewer slow to heat) gloves and goggles during this procedure. TOOLS: Deliming Solution Never siphon deliming