ページ1に含まれる内容の要旨
656
BLOOMFIELD INDUSTRIES
2 ERIK CIRCLE, P.O.Box 280
Verdi, NV 89439 U.S.A.
Customer Service (775) 345-0444 Ext.502
fax (775) 345-0569
www.wellsbloomfield.com
OWNERS MANUAL
LX
DECANTER
BREWER
MODELS
2212
2216
2216EX
2272
2274EX
Includes
INSTALLATION
OPERATION
USE & CARE
SERVICE
Model 2216
shown with
optional
decanters
p/n 74733 Rev. D
ページ2に含まれる内容の要旨
WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD It also does not apply if the serial nameplate has been INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service. workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment are based upon the limitations in this warranty. Seller
ページ3に含まれる内容の要旨
TABLE OF CONTENTS WARRANTY STATEMENT xi SPECIFICATIONS 1 Thank You for purchasing this FEATURES & OPERATING CONTROLS 2 Bloomfield Industries appliance. PRECAUTIONS & GENERAL INFORMATION 3 INSTALLATION INSTRUCTIONS 5 Proper installation, professional AGENCY APPROVAL INFORMATION
ページ4に含まれる内容の要旨
FEATURES & OPERATING CONTROLS DECANTER (IN BREWING POSITION) 12 3 4 CONTROL 11 5 6 7 8 910 PANEL 1. Brew Indicator Glows during brew cycle, flashes in “Brew Wait” 2. Heat Indicator Glows when heating elements are energized 3. Power Indicator Glows when power is on 4. Warmer Indicators Glow when individual warmers are turned on 5. Brew Key
ページ5に含まれる内容の要旨
PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: Injury Hazard All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in pr
ページ6に含まれる内容の要旨
INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: REFER TO EXPLODED VIEWS PAGES 16 thru 19 FOR To enable the installer to make COMPONENT NAMES/NUMBERS a quality installation and to minimize installation time, the 1. Unpack the unit. Inspect all components for completeness following suggestions and tests and condition. Ensure that all packing materials have been should be done before the removed from the unit. actual unit installati
ページ7に含まれる内容の要旨
INSTALLATION INSTRUCTIONS (continued) 4. A water shut-off valve should be installed on the incoming NOTE: This equipment must be water line in a convenient location (Use a low restriction type installed to comply with applica- valve, such as a 1/4-turn ball valve, to avoid loss of water ble federal, state and local flow thru the valve. codes and ordinances. 5. NSF requires that the brewer be able to be moved for cleaning underneath. A flex line or loops of copper tubing
ページ8に含まれる内容の要旨
OPERATION OPERATING INSTRUCTIONS To over-ride the Brew 1. Energizing the Brewer: When electricity has been connected to Wait mode, press and the unit, there will be a momentary flash of the power light. Turn hold the BREW key for the brewer on by pressing the POWER key. 3 seconds when the The brewer will start to fill the tank. With the brewer is in Brew Wait proper water supply the tank should be filled in mode (i.e. when brew light about 2½ minutes. Once filled,
ページ9に含まれる内容の要旨
OPERATION (continued) USER’S GUIDE WARNING: 1. Remove the brew chamber from under the spray head. Burn Hazard. Place one (1) genuine Bloomfield paper filter into the brew This appliance chamber. Add your choice of pre-measured ground coffee. dispenses very hot liquid. Shake the brew chamber gently to level the coffee. Serious bodily injury from Slide the brew chamber back into place. scalding can occur fro
ページ10に含まれる内容の要旨
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer CAUTION: Burn Hazard PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving FREQUENCY: Daily temperatures of coffee are extremely hot. TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Hot coffee will cause serious skin burns. Bristle Brush 1. Disconnect brewer from electric power. C
ページ11に含まれる内容の要旨
SERVICING — OPERATIONAL ADJUSTMENTS BREW BREW QUALITY DRIPOUT AFTER HOURS TIMER TEMP TIMER TIMER TIMER (IN SECONDS) (IN °F) (IN 5 MIN INCR) (IN SECONDS) (IN ONE HR INCR) TEMP WATER 210 194 70 60 3 LEVEL PROBE PROBE 185 20 100 320 OFF 205 OFF 120 30 90 OFF 6 A. Adjust Brew Time B. Adjust Brew Temperature C. Adjust Quality Timer UNDER TOP COVER D. Adjust Dripout Timer E. Adjust After Hours Timer AB CD E CAUTION: 4. Adjust Qualit
ページ12に含まれる内容の要旨
SERVICING INSTRUCTIONS — ELECTRICAL OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. WATER LEVEL CONTROLLER PROBE 2. Automatic fill is accomplished via a FILL SOLENOID FILL SOLENOID (32) and a WATER LEVEL PROBE (7). The probe FILL senses ground through the water in the tank. When the water level falls below the probe and ground is no longer BREW DRIP OUT TIME TI
ページ13に含まれる内容の要旨
SERVICING INSTRUCTIONS — ELECTRICAL 3 PROBE, TEMPERATURE (THERMISTOR) 4 THERMOSTAT, HI-LIMIT 5 GROMMET 7 PROBE, WATER LEVEL 27 8 SLEEVE, WATER LEVEL PROBE 15 ELEMENT, WATER HEATING 28 17 ASSEMBLY, TRIAC & HEAT SINK 18 BREW SOLENOID 20 CONTROLLER WARMER 27 COVER PLATE, WARMER MOUNTING 28 ELEMENT, WARMER 32 FILL SOLENOID 3 7 5 8 120V 4 UNITS 18 15 20 32 17 120/240V 4 UNITS E-MAXLX ELECTRICAL COMPONENT 11
ページ14に含まれる内容の要旨
SERVICING INSTRUCTIONS — PLUMBING OPERATION SEE PAGE 13 FOR COMPONENT NAMES/NUMBERS 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller. NOTE: The solenoid has an internal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the cap, inlet fitting and washer. With pliers, grasp the bar of
ページ15に含まれる内容の要旨
SERVICING INSTRUCTIONS — PLUMBING ITEM DESCRIPTION PART N0. USED ON 1 FAUCET, HOT WATER 8783-1 ALL 2 ASSEMBLY, WATER TANK (120V) 83500 2212, 2272 ASSEMBLY, WATER TANK (240V) 83753 2216 6 GASKET, TANK LID 83499 ALL 9 TANK LID 83504 ALL 10 RETAINING CLIP, TANK LID 83506 ALL 11 HOSE, OVERFLOW (2 pc SILICONE 4.5” LONG) 86014 ALL 12 HOSE, FAUCET SUPPLY (SILICONE, 10” LONG) 83538 ALL 13 TUBE, VENT (METAL, 2.3” LONG) 83384 ALL 14 TUBE, BREW SUPPLY VENTED ASSEMBLY 86013 ALL 16 TUBE, FILL (SI
ページ16に含まれる内容の要旨
SERVICING INSTRUCTIONS — DE-LIMING HEATER TANK CAUTION - CHEMICAL 1. Disconnect brewer form the electrical supply. Turn off BURN HAZARD the water supply and disconnect water supply from the brewer inlet fitting. De-liming chemicals are caustic. 2. Remove the top panel or top warmer section to gain Wear appropriate protective gloves access to internal components. and goggles during this procedure. Never siphon de-liming chemicals 3. Disconnect water
ページ17に含まれる内容の要旨
SERVICING INSTRUCTIONS — DIAGNOSTICS & TROUBLESHOOTING) If the E-Max™ LX goes into an error mode as outlined below, it IMPORTANT: The following will probably be necessary to reset the brewer in order to test troubleshooting suggestions are for individual components. Note the reset procedure below: operator reference only. * FOR “LOW WATER” OR “OVERHEAT” ERRORS: All servicing and/or repairs must be PRESS & HOLD CANCEL FOR 3 SECONDS, OR perfor
ページ18に含まれる内容の要旨
EXPLODED VIEW — IN-LINE MODELS 16
ページ19に含まれる内容の要旨
PARTS LIST — IN-LINE MODELS 17
ページ20に含まれる内容の要旨
EXPLODED VIEW — STEP-UP MODELS 18