ページ1に含まれる内容の要旨
™
WhisperFlo Pump Owner's Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Table of Contents
SECTION I. GENERAL INFORMATION............................................................................................ 2
SECTION II. MAINTENANCE ......................................................................................................... 3
SECTION III. SERVICE ..................................................................................
ページ2に含まれる内容の要旨
Note When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you must use a No. 8 AWG or larger conductor to connect to bonding conductor lug. WARNING To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. CAUTION This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed i
ページ3に含まれる内容の要旨
6. Permanently ground the motor using the green ground terminal Bonding Lug located on the inside of the motor canopy or access plate, see Figure 1. Use the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical service ground. Ground Screw 7. Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid No. 8 AWG or larger copper conductor. Run a wire from the external bonding to the pool bond
ページ4に含まれる内容の要旨
WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS. 10. Open the High Flow™ manual air relief valve on top of the filter. Clamp 11. Stand clear of the filter. Start the pump. Lid 12. Blee
ページ5に含まれる内容の要旨
SECTION III. SERVICE. WARNING Risk of electrical shock or electrocution. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property. Always disconnect power to
ページ6に含まれる内容の要旨
B. Pump Reassembly/Seal Replacement; see Section V, Technical Bolt Data, Figure 4. 1. When installing the replacement shaft seal, use silicone Seal Plate sealant on the metal portion, before pressing into the seal plate. Gasket 2. Before installing the ceramic section of the seal into the impeller, be sure the impeller is clean. Use a light density Lockscrew Water Slinger soap and water to seal the seal. Press the seal into the Motor Shaft impeller with your thumbs and wipe off the ceramic and c
ページ7に含まれる内容の要旨
B. Priming the Pump. 1. The pump strainer pot must be filled with water before the pump is initially started. Follow these steps to prime the pump. a. Remove the pump lid plastic clamp. Remove the pump lid. b. Fill the pump strainer pot with water. c. Reassemble the pump cover and plastic clamp onto the strainer pot. The pump is now ready to prime. d. Open the air release valve on the filter, and stand clear of the filter. e. Turn on the switch or time clock. f. When water comes out of the air r
ページ8に含まれる内容の要旨
SECTION VI. TECHNICAL DATA. 26 28 27 A. Replacement Parts. Item Part Model Description Item Part Model Description No. No. No. No. No. No. 1 357150 CLAMP POT (Black) 20 07-0929 P10313 FOOT INSERT WFE PUMP 1 357199 CLAMP POT (Almond) 20a 357160 FOOT INSERT (CANADA ONLY) 2 07-0795 P08080 COVER LEXAN AQ/WFE PUMP 21 07-1657 P26948 SCREW ¼ - 20 X 1 in. HH s/s, 2 req. 2 357151 COVER LEXAN WFE PUMP 22 07-1406 P23802 NUT ¼ - 20 HEX. hd. s/s, 2 req. 3 350013 O-RING WFE COVER 23 07-2183 P35010 Wsh. FLAT ¼
ページ9に含まれる内容の要旨
B. Pump Curves. Single Speed Models Dual Speed Models SAVE THESE INSTRUCTIONS. Rev. D 6-5-01 9 P/N 071109
ページ10に含まれる内容の要旨
™ Pentair Pool Products WhisperFlo Circulating Pump Limited Warranty Pentair Pool Products manufactures its WhisperFlo circulating Pentair Pool Products is not, however responsible under pumps under high standards of workmanship and with high this warranty for any cost of shipping or transportation of quality materials. Accordingly, Pentair Pool Products expressly the filter or part thereof to or from the service department. warrants those pump models as follows: Also, Pentair Pool Products is n